The effect of functional knee brace design and hinge misalignment on lower limb joint mechanics

被引:21
|
作者
Singer, Jonathan C. [2 ]
Lamontagne, Mario [1 ]
机构
[1] Univ Ottawa, Sch Human Kinet, Ottawa, ON K1N 6N5, Canada
[2] Univ Waterloo, Dept Kinesiol, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
functional knee brace; anterior cruciate ligament (ACL); gait analysis;
D O I
10.1016/j.clinbiomech.2007.08.013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Knee bracing has been shown to alter lower limb joint mechanics, which may protect the anterior cruciate ligament. The effect of brace alignment and brace type, however, remains largely unknown. This study was conducted to determine whether the use of a functional knee brace, the type of brace used or its alignment relative to the knee causes biomechanical alterations to gait. Methods. Ten healthy participants took part in two walking conditions (aligned brace and misaligned brace) for two different types of brace (sleeve brace with bilateral hinges and hinge-post-shell). A non-braced condition was included as a baseline measure. Three-dimensional kinematics and force platform data were used to calculate the joint intersegmental forces and net joint moments of the ankle, knee and hip. Findings. In comparison to non-braced walking, the shell brace in its aligned position significantly reduced the peak ankle plantarflexor moment. There was a decreased peak knee flexion angle with both the aligned shell and sleeve braces. The shell brace in its aligned position significantly increased peak knee adduction and reduced peak knee internal rotation. Interpretation. In this sample of healthy participants, functional knee bracing failed to alter lower limb mechanics in such a way that would reduce the force transmitted to the anterior cruciate ligament. In addition, although there were brace induced changes in lower limb kinematics with 2 cm of distal hinge misalignment, it is unlikely that hinge misalignment of this magnitude is detrimental to an uninjured knee joint during walking. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 50 条
  • [31] Lower-limb coordination and shoulder joint mechanics in the tennis serve
    Reid, Machar
    Elliott, Bruce
    Alderson, Jacqueline
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (02): : 308 - 315
  • [32] IMPLEMENTATION OF AN ADJUSTABLE COMPLIANT KNEE JOINT IN A LOWER-LIMB EXOSKELETON
    Sanz-Merodio, D.
    Cestari, M.
    Arevalo, J. C.
    Garcia, E.
    NATURE INSPIRED MOBILE ROBOTICS, 2013, : 223 - 231
  • [33] Lower-Limb Multi-Joint Stiffness of Knee and Ankle
    Kang, Sang Hoon
    Ren, Yupeng
    Xu, Dali
    Zhang, Li-Qun
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 4009 - 4012
  • [34] Continuous Angle Prediction of Lower Limb Knee Joint Based on sEMG
    Li, C.
    He, Haiyan
    Yin, Shiyi
    Deng, Huiyin
    Zhu, Yanfei
    IEEE INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN SYSTEMS SCIENCE AND ENGINEERING (IEEE RASSE 2021), 2021,
  • [35] Application of a High-Reduction Motion Unit for Slight Joint Actuator of Lower Limb Brace
    Yamamoto, K. L.
    Genda, E.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2844 - +
  • [36] Effects of toe-out and toe-in gait with varying walking speeds on knee joint mechanics and lower limb energetics
    Khan, Soobia Saad
    Khan, Saad Jawaid
    Usman, Juliana
    GAIT & POSTURE, 2017, 53 : 185 - 192
  • [37] A functional knee brace alters joint torque and power patterns during walking and running
    DeVita, P
    Torry, M
    Glover, KL
    Speroni, DL
    JOURNAL OF BIOMECHANICS, 1996, 29 (05) : 583 - 588
  • [38] The effect of knee joint rotation in the sagittal and axial plane on the measurement accuracy of coronal alignment of the lower limb
    Hyun-Soo Moon
    Chong-Hyuk Choi
    Min Jung
    Dae-Young Lee
    Jung-Hwan Kim
    Sung-Hwan Kim
    BMC Musculoskeletal Disorders, 21
  • [39] The effect of knee joint rotation in the sagittal and axial plane on the measurement accuracy of coronal alignment of the lower limb
    Moon, Hyun-Soo
    Choi, Chong-Hyuk
    Jung, Min
    Lee, Dae-Young
    Kim, Jung-Hwan
    Kim, Sung-Hwan
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [40] Design and analysis of a novel prosthetic limb for lower knee amputee
    A A.K.
    T P.
    V V.
    R M.
    P S.
    Research on Biomedical Engineering, 2024, 40 (3-4) : 563 - 577