Validating BMS sensors for chiller condition monitoring

被引:0
|
作者
Wang, SW [1 ]
Wang, JB [1 ]
Burnett, J [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
chiller monitoring; diagnosis; evaluation; fault detection; sensor;
D O I
10.1191/014233101681274142
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A method based on energy balance is developed for diagnosing and validating the health states of the building management system (BMS) sensors (faults and biases) for monitoring chiller condition. A normalized energy balance residual is defined and used as the indices for fault detection. A characteristic quantity is derived for diagnosing flow meter faults without needing to know the temperature sensor biases. A robust algorithm is developed for estimating the magnitude of the flow meter biases. The sensor fault validation method, verification of the method using dynamic simulation programs and application to an existing chilling plant are presented.
引用
收藏
页码:201 / 225
页数:25
相关论文
共 50 条
  • [31] Monitoring chiller plant performance
    Gifford, Henry
    ASHRAE Journal, 2008, 50 (06)
  • [32] Condition monitoring opportunities using vehicle-based sensors
    Ward, C. P.
    Weston, P. F.
    Stewart, E. J. C.
    Li, H.
    Goodall, R. M.
    Roberts, C.
    Mei, T. X.
    Charles, G.
    Dixon, R.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART F-JOURNAL OF RAIL AND RAPID TRANSIT, 2011, 225 (F2) : 202 - 218
  • [33] Magnetoresistive sensors for the condition monitoring of high-frequency spindles
    Slatter, Rolf
    Holland, Lars
    Abele, Eberhard
    7TH HPC 2016 - CIRP CONFERENCE ON HIGH PERFORMANCE CUTTING, 2016, 46 : 177 - 180
  • [34] END-OF-CAR DEVICE CONDITION MONITORING WITH ONBOARD SENSORS
    Hopkins, Brad M.
    Seidel, Andrew
    Maraini, Dan
    Shahidi, Parham
    PROCEEDINGS OF THE ASME JOINT RAIL CONFERENCE, 2015, 2015,
  • [35] An investigation of rail Condition monitoring by Fibre Bragg Grating sensors
    Ho, T.K.
    Liu, S.Y.
    Lee, K.Y.
    Ho, Y.T.
    Ho, K.H.
    Mccusker, A.
    Kam, J.
    Tam, H.Y.
    Ho, S.L.
    HKIE Transactions Hong Kong Institution of Engineers, 2009, 16 (02): : 9 - 15
  • [36] Condition Monitoring of Electrolytic Capacitors in Boost Converters by Magnetic Sensors
    Miao, Wenchao
    Liu, Xuyang
    Lam, K. H.
    Pong, Philip W. T.
    IEEE SENSORS JOURNAL, 2019, 19 (22) : 10393 - 10402
  • [37] Hybrid energy harvesting for condition monitoring sensors in power grids
    Yang, Feng
    Du, Lin
    Chen, Weigen
    Li, Jian
    Wang, Youyuan
    Wang, Disheng
    ENERGY, 2017, 118 : 435 - 445
  • [38] Remote Condition Monitoring of Railway Track using FBG sensors
    Roveri, N.
    Carcaterra, A.
    Sestieri, A.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2014) AND INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2014), 2014, : 3527 - 3541
  • [39] Wireless smart sensors for monitoring the health condition of civil infrastructure
    Amezquita-Sanchez, J. P.
    Valtierra-Rodriguez, M.
    Adeli, H.
    SCIENTIA IRANICA, 2018, 25 (06) : 2913 - 2925
  • [40] Application of microacoustic viscosity sensors for online oil condition monitoring
    Agoston, A
    Ötsch, C
    Jakoby, B
    SENSORS AND MEASURING SYSTEMS 2004, 2004, 1829 : 833 - 836