Method to traceably determine the refractive index by measuring the angle of minimum deviation

被引:6
|
作者
Kuiper, Martine [1 ,2 ,3 ,4 ]
Koops, Richard [1 ]
Nieuwland, Rienk [2 ,3 ]
van der Pol, Edwin [2 ,3 ,4 ,5 ,6 ]
机构
[1] Natl Metrol Inst, VSL, Delft, Netherlands
[2] Univ Amsterdam, Amsterdam Univ Med Ctr, Lab Expt Clin Chem, Locat AMC, Amsterdam, Netherlands
[3] Univ Amsterdam, Amsterdam Univ Med Ctr, Vesicle Observat Ctr, Locat AMC, Amsterdam, Netherlands
[4] Univ Amsterdam, Amsterdam Univ Med Ctr, Locat AMC, Biomed Engn & Phys, Amsterdam, Netherlands
[5] Atherosclerosis & Ischem Syndromes, Amsterdam Cardiovasc Sci, Amsterdam, Netherlands
[6] Canc Ctr Amsterdam, Imaging & Biomarkers, Amsterdam, Netherlands
基金
欧盟地平线“2020”;
关键词
angle of minimum deviation; fused silica; measurement uncertainty; standardization; refractive index; traceable measurements; uncertainty budget; FUSED-SILICA; THERMOOPTICAL COEFFICIENTS; GLASS; DISPERSION;
D O I
10.1088/1681-7575/ac8991
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The refractive index (RI) of a solid depends on the illumination wavelength, temperature and material properties, such as the chemical composition, crystal structure, and isotropy. RI measurements, however, also depend on environmental conditions, such as the temperature, pressure, CO2 concentration and humidity of the surrounding air. As these environmental conditions are not always reported, reported values of the RI are often irreproducible. Here we describe a new optical set-up based on the angle of minimum deviation to traceably measure the RI at controlled temperature, pressure, humidity, and CO2 concentration of the surrounding air. Advantages of the reported method are that (I) we perform RI measurements without the need for an independent measurement of the prism angles, and (II) correlations in the uncertainty propagation reduce the sensitivity coefficients greatly. The absolute RI of fused silica at 20.00 degrees C is 1.470 091 at 404.66 nm, 1.467 169 at 435.83 nm, 1.460 459 at 546.07 nm, and 1.459 237 at 579.07 nm. The expanded uncertainty (k = 2) of the set-up and procedure is 1.4 x 10(-6) for 404.66 nm, 435.83 nm, and 546.07 nm and 1.7 x 10(-6) for 579.07 nm. The main factors affecting the expanded uncertainty are the calibration uncertainty of the rotary stage, and the repeatability of the measurement.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Improved retroreflection method for measuring the refractive index of liquids
    Shao, Duo
    Tian, Linghao
    Chen, Jingfei
    Chen, Xianfeng
    [J]. APPLIED OPTICS, 2010, 49 (16) : 3049 - 3052
  • [32] A method for measuring the complex refractive index of a turbid medium
    Jian, ZC
    Lin, JY
    Hsieh, PJ
    Chen, HW
    Su, DC
    [J]. Optical Measurement Systems for Industrial Inspection IV, Pts 1 and 2, 2005, 5856 : 1036 - 1043
  • [33] METHOD OF MEASURING THE REFRACTIVE-INDEX OF GLASS PLATES
    MISHCHENKO, YV
    [J]. MEASUREMENT TECHNIQUES USSR, 1990, 33 (08): : 803 - 808
  • [34] A NEW METHOD OF MEASURING SMALL REFRACTIVE INDEX DIFFERENCES
    SVENSSON, H
    ODENGRIM, K
    [J]. ACTA CHEMICA SCANDINAVICA, 1952, 6 (05): : 720 - 728
  • [35] New Method for Measuring the Refractive Index of Flowing Liquid
    Davydov, V. V.
    Moroz, A. V.
    Nikolaev, D. I.
    [J]. OPTICS AND SPECTROSCOPY, 2021, 129 (08) : 915 - 921
  • [36] Measuring refractive index using the focal displacement method
    Murray, Joel M.
    Wei, Jean
    Barnes, Jacob O.
    Slagle, Jonathan E.
    Guha, Shekhar
    [J]. APPLIED OPTICS, 2014, 53 (17) : 3748 - 3752
  • [37] Simple method for measuring refractive index of supercritical fluids
    Kirby, CF
    McHugh, MA
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (08): : 3150 - 3153
  • [38] Express method for measuring the refractive index of transparent fibres
    Kokodii, M.
    Natarova, A.
    Priz, I.
    Biesova, O.
    [J]. UKRAINIAN METROLOGICAL JOURNAL, 2022, (03): : 43 - 48
  • [39] METHOD FOR MEASURING THE REFRACTIVE-INDEX OF TRANSPARENT SOLIDS
    BASS, JD
    WEIDNER, DJ
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (10): : 1569 - 1573
  • [40] An improved method for measuring refractive-index of a medium
    Su, DC
    Lee, JY
    [J]. LASER INTERFEROMETRY IX: TECHNIQUES AND ANALYSIS, 1998, 3478 : 245 - 252