Microstructural analysis of CdTe radiation detectors with indium electrodes

被引:0
|
作者
Moriyama, M
Kunisu, M
Kiyamu, A
Ohno, R
Murakami, M
机构
[1] Toyoda Gosei Co Ltd, Div Optoelect, Aichi 4901312, Japan
[2] Kyoto Univ, Dept Mat Sci & Engn, Kyoto 6068501, Japan
[3] ACRORAD, Okinawa 9042234, Japan
关键词
p-i-n diode; radiation detectors; cadmium telluride; heterojunction; indium telluride;
D O I
10.2320/matertrans.46.1991
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to understand the formation mechanisms of indium contacts which were previously developed for CdTe radiation detectors with p-i-n structure, microstructure of the indium contacts which were deposited at various substrate temperatures on the p-CdTe substrates and subsequently annealed at temperature ranging from 200 to 400 degrees C were analyzed by X-ray diffraction and transmission electron microscopy. The microstructural analysis revealed that reactions between CdTe and In were enhanced by the substrate heating during deposition and growth of In4Te3 or InTe compounds on the CdTe surface was observed. Current leakage and stability of the CdTe radiation detectors were strongly correlated with the microstructure of CdTe/contact interfaces. The indium contacts, which were deposited at substrate temperature of 400 or 350 degrees C and subsequently annealed at 350 degrees C for I h in vacuum, displayed rectifying I-V behaviors and satisfied the device requirement. In addition, the excellent thermal stability of these contacts was observed. We found that the formation of the InTe compounds was essential for production of the p-i-n CdTe detector devices which require highly reliable rectifying contacts.
引用
收藏
页码:1991 / 1995
页数:5
相关论文
共 50 条
  • [41] Simulation of CdTe:Ge crystal properties for nuclear radiation detectors
    Sochinskii, N. V.
    Lozano, M.
    Pellegrini, G.
    Ullan, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01): : 451 - 454
  • [42] Gamma-radiation dosimetry with semiconductor CdTe and CdZnTe detectors
    Rybka, AV
    Davydov, LN
    Shlyakhov, IN
    Kutny, VE
    Prokhoretz, IM
    Kutny, DV
    Orobinsky, AN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2): : 147 - 156
  • [43] HIGH-QUALITY CDTE AND ITS APPLICATION TO RADIATION DETECTORS
    OHMORI, M
    IWASE, Y
    OHNO, R
    MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY, 1993, 16 (1-3): : 283 - 290
  • [44] Temporal and temperature evolution of electric field in CdTe:In radiation detectors
    Dedic, V.
    Zazvorka, J.
    Rejhon, M.
    Franc, J.
    Grill, R.
    Sellin, P. J.
    JOURNAL OF APPLIED PHYSICS, 2014, 116 (05)
  • [45] ON CDTE DETECTORS
    ARKADEVA, EN
    MASLOVA, LV
    MATVEEV, OA
    RYVKIN, SM
    RUD, YV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1968, NS15 (03) : 258 - +
  • [46] Indium Kα radiation from a MetalJet X-ray source: comparison of the Eiger2 CdTe and Photon III detectors
    Ruth, Paul Niklas
    Graw, Nico
    Ernemann, Tobias
    Herbst-Irmer, Regine
    Stalke, Dietmar
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2023, 56 : 1322 - 1329
  • [47] Synthesis and structural analysis of indium iodide polycrystal for room-temperature nuclear radiation detectors
    School of Information Science and Engineering, The Key Laboratory for Special Fiber and Fiber Sensor of Hebei Province, Yanshan University, Qinhuangdao, China
    Rengong Jingti Xuebao, 6 (1460-1464):
  • [48] Comparison of the radiation damage induced by thermal neutrons in CdTe and CdZnTe detectors
    Chirco, P
    Morigi, MP
    Zanarini, M
    Cavallini, A
    Fraboni, B
    Auricchio, N
    Caroli, E
    Dusi, W
    Fougeres, P
    Hage-Ali, M
    Siffert, P
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 : 424 - 432
  • [49] Frontal IBICC study of the induced proton radiation damage in CdTe detectors
    Pastuovic, Z
    Jaksic, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 : 344 - 348
  • [50] Influence of fast neutron irradiation on signal response of CdTe radiation detectors
    Miyamaru, H
    Fujii, K
    Iida, T
    Takahashi, A
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1996, 33 (09) : 744 - 746