The use of emulsions for the determination of methylmercury and inorganic mercury in fish-eggs oil by cold vapor generation in a flow injection system with atomic absorption spectrometric detection

被引:23
|
作者
Burguera, JL
Quintana, IA
Salager, JL
Burguera, M
Rondón, C
Carrero, P
de Salager, RA
de Peña, YP
机构
[1] Univ Los Andes, Fac Sci, Venezuela Andean Inst Chem Res, IVAIQUIM, Merida 5101A, Venezuela
[2] Univ Havana, IMRE, Havana, Cuba
[3] Univ Los Andes, Fac Engn, FIRP, Merida 5101, Venezuela
关键词
D O I
10.1039/a809024f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line time based injection system used in conjunction with cold vapor generation atomic absorption spectrometry and microwave-aided oxidation with potassium persulfate has been developed for the determination of the different mercury species in fish-eggs oil samples. A three-phase surfactant-oil-water emulsion produced an advantageous flow when a peristaltic pump was used to introduce the highly viscous sample into the system. The optimum proportion of the oil-water mixture ratio was 2:3 v/v with a Tween 20 surfactant concentration in the emulsion of 0.008% v/v. Inorganic mercury was determined after reduction with sodium borohydride while total mercury was determined after an oxidation step with persulfate prior to the reduction step to elemental mercury with the same reducing agent. The difference between total and inorganic mercury determined the organomercury content in samples. A linear calibration graph was obtained in the range 0.1-20 mu g 1(-1) of Hg2+ by injecting 0.7 mi of samples. The detection limits based on 3 sigma of the blank signals were 0.11 and 0.12 mu g 1(-1) for total and inorganic mercury, respectively. The relative standard deviation of ten independent measurements were 2.8 and 2.2% for 10 mu g 1(-1) and 8.8 and 9.0% for 0.1 mu g 1(-1) amounts of total and inorganic mercury, respectively. The recoveries of 0.3, 0.6 and 8 mu g 1(-1) of inorganic and organic mercury added to fish-eggs oil samples ranged from 93.0 to 94.8% and from 100 to 106%, respectively. Good agreement with those values obtained for total mercury content in real samples by electrothermal atomic absorption spectrometry was also obtained, differences between mean values were <7%. With the proposed procedure, 22 proteropterous catfish-eggs oil samples from the northwestern coast of Venezuela were measured; while the organic mercury lay in the range 2.0 and 3.3 mu g 1(-1), inorganic mercury was not detected.
引用
收藏
页码:593 / 599
页数:7
相关论文
共 50 条
  • [1] Methylmercury and inorganic mercury determination in fish by cold vapour generation atomic absorption spectrometry
    Ubillús, F
    Alegría, A
    Barberá, R
    Farré, R
    Lagarda, MJ
    FOOD CHEMISTRY, 2000, 71 (04) : 529 - 533
  • [2] Determination of mercury in fish by cold vapor atomic absorption spectrophotometry using a multicommuted flow injection analysis system
    Escola Superior de Biotecnologia, Universidade Católica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto, Portugal
    Anal. Sci., 6 (861-864):
  • [3] Determination of mercury in fish by cold vapor atomic absorption spectrophotometry using a multicommuted flow injection analysis system
    Silva, M. Fatima
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    ANALYTICAL SCIENCES, 2006, 22 (06) : 861 - 864
  • [4] Sequential Injection Vapor Generation Atomic Absorption Spectrometric Determination of Mercury and Arsenic
    Ma, Hongbing
    Xu, Shukun
    Zhou, Huanying
    Wang, Shili
    Fang, Zhaolun
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2000, 20 (04): : 531 - 532
  • [5] Determination of Mercury in Fish by Cold Vapor Atomic Absorption Spectrophotometry Using a Multicommuted Flow Injection Analysis System
    M. Fátima Silva
    Ildikó V. Tóth
    António O. S. S. Rangel
    Analytical Sciences, 2006, 22 : 861 - 864
  • [6] Sequential injection vapor generation atomic absorption spectrometric determination of mercury and arsenic
    Ma, HB
    Xu, SK
    Zhou, HY
    Wang, SL
    Fang, ZL
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2000, 20 (04) : 529 - 532
  • [7] ION-CHROMATOGRAPHIC SEPARATION AND ONLINE COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF METHYLMERCURY, ETHYLMERCURY AND INORGANIC MERCURY
    SARZANINI, C
    SACCHERO, G
    ACETO, M
    ABOLLINO, O
    MENTASTI, E
    ANALYTICA CHIMICA ACTA, 1994, 284 (03) : 661 - 667
  • [8] DETERMINATION OF SUBMICROGRAM QUANTITIES OF MERCURY IN FISH AND EGGS BY COLD VAPOR ATOMIC ABSORPTION PHOTOMETRY
    PAPPAS, EG
    ROSENBER.LA
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1966, 49 (04): : 792 - &
  • [9] SELECTIVE DETERMINATION OF INORGANIC MERCURY AND METHYLMERCURY IN TISSUES BY CONTINUOUS-FLOW AND COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY
    ATALLAH, RH
    KALMAN, DA
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (02) : 87 - 92
  • [10] Determination of mercury by multisyringe flow injection system with cold-vapor atomic absorption spectrometry
    Leal, L. O.
    Elsholz, O.
    Forteza, R.
    Cerda, V.
    ANALYTICA CHIMICA ACTA, 2006, 573 : 399 - 405