Sequential Injection Vapor Generation Atomic Absorption Spectrometric Determination of Mercury and Arsenic

被引:0
|
作者
Ma, Hongbing [1 ]
Xu, Shukun [1 ]
Zhou, Huanying [1 ]
Wang, Shili [1 ]
Fang, Zhaolun [1 ]
机构
[1] Box 332, Res. Center for Analytical Sciences, Northeastern University, 110006 Shenyang, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A sequential injection vapor generation atomic absorption spectrometric (SI-VGAAS) method for the determination of mercury and arsenic was developed, characterized by reagent merging using a double-syringe pump and a multi-position selector valve. A sample throughput of 120 h-1 was achieved with 500 μL sample with a precision of 2.2% for mercury at 8.0 μg·L-1 ( n = 11 ) and 1.4% for arsenic at 6.0 μg·L-1 ( n = 11 ) levels and a detection limit of 0.15 μg·L-1 for mercury and 0.07 μg·L-1 for arsenic. The method was applied to the analysis of geochemical standard reference material GSS-5, and good agreement with the certified values were obtained.
引用
收藏
页码:531 / 532
相关论文
共 50 条
  • [1] Sequential injection vapor generation atomic absorption spectrometric determination of mercury and arsenic
    Ma, HB
    Xu, SK
    Zhou, HY
    Wang, SL
    Fang, ZL
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2000, 20 (04) : 529 - 532
  • [2] A sequential injection cold-vapor atomic absorption method for the determination of total mercury
    W. E. Doering
    R. R. James
    R. T. Echols
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 475 - 479
  • [3] A sequential injection cold-vapor atomic absorption method for the determination of total mercury
    Doering, WE
    James, RR
    Echols, RT
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (05): : 475 - 479
  • [4] Determination of mercury and arsenic in white beet sugar by vapor generation atomic absorption spectrometry
    Ronda, F
    Sancho, D
    Blanco, CA
    Gómez, M
    Caballero, PA
    ZUCKERINDUSTRIE, 2002, 127 (10): : 763 - 767
  • [5] Sequential injection analysis system for the determination of arsenic by hydride generation atomic absorption spectrometry
    Yin, XF
    Zhang, JJ
    Wang, XF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (10) : 1365 - 1367
  • [6] A low consumption air-segmented sequential injection vapor generation system for the determination of mercury by atomic absorption spectrometry
    Ma, HB
    Fang, ZL
    Wu, JF
    Liu, SS
    TALANTA, 1999, 49 (01) : 125 - 133
  • [7] Flow injection-hydride generation atomic absorption spectrometric determination of selenium, arsenic and bismuth
    Zhang, Yanlin
    Adeloju, Samuel B.
    TALANTA, 2008, 76 (04) : 724 - 730
  • [8] Sequential injection analysis system for determination of mercury by cold-vapor atomic absorption spectroscopy
    de Mirabó, FMB
    Thomas, AC
    Rubí, E
    Forteza, R
    Cerdà, V
    ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) : 203 - 210
  • [9] A novel sequential injection - Cold vapour atomic absorption spectrometric system for rapid and reliable determination of mercury
    Zhang, Yanlin
    Adeloju, Samuel B.
    TALANTA, 2008, 74 (04) : 951 - 957
  • [10] Flow injection hydride generation electrothermal atomic absorption spectrometric determination of toxicologically relevant arsenic in urine
    Petrov, Panayot K.
    Serafimovski, Ivan
    Stafilov, Trajice
    Tsalev, Dimiter L.
    TALANTA, 2006, 69 (05) : 1112 - 1117