Impedance monitoring during catheter ablation of atrial fibrillation

被引:16
|
作者
Vaseghi, M [1 ]
Cesario, DA [1 ]
Valderrabano, M [1 ]
Boyle, NG [1 ]
Ratib, O [1 ]
Finn, JP [1 ]
Wiener, I [1 ]
Shivkumar, K [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Cardiac Arrhythmia Ctr, Dept Med,Div Cardiol, Los Angeles, CA 90095 USA
关键词
impedance; pulmonary vein stenosis; catheter ablation;
D O I
10.1016/j.hrthm.2005.06.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Delivery of radiofrequency energy in proximity of a pulmonary vein can cause vein stenosis. A sudden decrease in impedance as the catheter is moved from the vein into the left atrium (LA) has been used to define the pulmonary vein-LA transition during ablation procedures. OBJECTIVES The purpose of this study was to define the variables affecting impedance measurement. METHODS In vitro analysis of impedance was performed in a saline bath using sheaths and a plastic stereolithographic model of the LA. Impedance was continuously monitored during a calibrated pullback from the pulmonary vein into the LA in 37 veins of 10 patients referred for catheter ablation. Location of the catheter was confirmed by the following imaging modalities: intracardiac echocardiography, contrast venography, electroanatomic mapping, and computed tomography/magnetic resonance imaging (offline) in all patients. RESULTS Larger cross-sectional areas containing the catheter correlated with lower impedance in an exponential manner both with respect to sheath size (R-2 = 0.99) and in the stereolithographic model (R-2 = 0.91). In vivo, the impedance in the pulmonary veins decreased in an exponential manner as the catheter was pulled back into the LA. However, impedance at the vein orifice was not significantly higher than the LA. A defined cutoff value for defining the pulmonary vein-LA transition could not be identified. CONCLUSION The primary determinant of impedance is the cross-sectional area of the space containing the catheter. Impedance monitoring alone does not guarantee a catheter tip position outside the pulmonary vein. Intraprocedural imaging confirmation should be considered to avoid radiofrequency application within pulmonary veins.
引用
收藏
页码:914 / 920
页数:7
相关论文
共 50 条
  • [31] Catheter Ablation for atrial fibrillation
    De Bortoli, Alessandro
    [J]. TIDSSKRIFT FOR DEN NORSKE LAEGEFORENING, 2015, 135 (16) : 1485 - 1485
  • [32] Catheter ablation for atrial fibrillation
    Jais, P
    Sanders, P
    Hsu, LF
    Hocini, M
    Haissaguerre, M
    [J]. HEART, 2005, 91 (01) : 7 - 9
  • [33] Catheter ablation of atrial fibrillation
    Li-Wei Lo
    Shih-Ann Chen
    [J]. 中华医学杂志(英文版), 2013, 126 (14) : 2753 - 2761
  • [34] Catheter Ablation of Atrial Fibrillation
    Ching, Chi Keong
    Patel, Dimpi
    Natale, Andrea
    [J]. JOURNAL OF ARRHYTHMIA, 2007, 23 (02) : 85 - 101
  • [35] Catheter Ablation of Atrial Fibrillation
    Kim, Young-Hoon
    [J]. JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2006, 49 (09): : 837 - 845
  • [36] Catheter Ablation for Atrial Fibrillation
    Wazni, Oussama
    Wilkoff, Bruce
    Saliba, Walid
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (24): : 2296 - 2304
  • [37] Catheter ablation of atrial fibrillation
    Callahan, Thomas D.
    Natale, Andrea
    [J]. MEDICAL CLINICS OF NORTH AMERICA, 2008, 92 (01) : 179 - +
  • [38] Catheter Ablation for Atrial Fibrillation
    Kumagai, Koichiro
    [J]. JOURNAL OF ARRHYTHMIA, 2005, 21 (05) : 510 - 517
  • [39] Catheter ablation for atrial fibrillation
    O'Neill, Mark D.
    Jais, Pierre
    Hocini, Meleze
    Sacher, Frederic
    Klein, George J.
    Clementy, Jacques
    Haissaguerre, Michel
    [J]. CIRCULATION, 2007, 116 (13) : 1515 - 1523
  • [40] Movement of the esophagus during left atrial catheter ablation for atrial fibrillation
    Good, E
    Oral, H
    Lemola, K
    Han, J
    Tamirisa, K
    Igic, P
    Elmouchi, D
    Tschopp, D
    Reich, S
    Chugh, A
    Bogun, F
    Pelosi, F
    Morady, F
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (11) : 2107 - 2110