Impedance monitoring during catheter ablation of atrial fibrillation

被引:16
|
作者
Vaseghi, M [1 ]
Cesario, DA [1 ]
Valderrabano, M [1 ]
Boyle, NG [1 ]
Ratib, O [1 ]
Finn, JP [1 ]
Wiener, I [1 ]
Shivkumar, K [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Cardiac Arrhythmia Ctr, Dept Med,Div Cardiol, Los Angeles, CA 90095 USA
关键词
impedance; pulmonary vein stenosis; catheter ablation;
D O I
10.1016/j.hrthm.2005.06.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Delivery of radiofrequency energy in proximity of a pulmonary vein can cause vein stenosis. A sudden decrease in impedance as the catheter is moved from the vein into the left atrium (LA) has been used to define the pulmonary vein-LA transition during ablation procedures. OBJECTIVES The purpose of this study was to define the variables affecting impedance measurement. METHODS In vitro analysis of impedance was performed in a saline bath using sheaths and a plastic stereolithographic model of the LA. Impedance was continuously monitored during a calibrated pullback from the pulmonary vein into the LA in 37 veins of 10 patients referred for catheter ablation. Location of the catheter was confirmed by the following imaging modalities: intracardiac echocardiography, contrast venography, electroanatomic mapping, and computed tomography/magnetic resonance imaging (offline) in all patients. RESULTS Larger cross-sectional areas containing the catheter correlated with lower impedance in an exponential manner both with respect to sheath size (R-2 = 0.99) and in the stereolithographic model (R-2 = 0.91). In vivo, the impedance in the pulmonary veins decreased in an exponential manner as the catheter was pulled back into the LA. However, impedance at the vein orifice was not significantly higher than the LA. A defined cutoff value for defining the pulmonary vein-LA transition could not be identified. CONCLUSION The primary determinant of impedance is the cross-sectional area of the space containing the catheter. Impedance monitoring alone does not guarantee a catheter tip position outside the pulmonary vein. Intraprocedural imaging confirmation should be considered to avoid radiofrequency application within pulmonary veins.
引用
收藏
页码:914 / 920
页数:7
相关论文
共 50 条
  • [1] Limitations of impedance monitoring during catheter ablation of atrial fibrillation
    Shivkumar, K
    Swerdlow, CD
    Finn, P
    Ratib, O
    Cesario, D
    Valderrabano, M
    Ji, S
    Shannon, KM
    Weiss, JN
    Wiener, I
    [J]. CIRCULATION, 2003, 108 (17) : 618 - 618
  • [2] Esophageal temperature monitoring during left atrial catheter ablation for atrial fibrillation
    Cesario, D
    Shivkumar, K
    Valderrabano, M
    Wiener, I
    Swerdlow, C
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 114A - 115A
  • [3] Esophageal pressure monitoring for airway management during catheter ablation of atrial fibrillation
    Iwasaki, Yu-Ki
    Fujimoto, Yuhi
    Oka, Eiichiro
    Hagiwara, Kanako Ito
    Takahashi, Kenta
    Tsuboi, Ippei
    Hayashi, Hiroshi
    Yodogawa, Kenji
    Hayashi, Meiso
    Miyauchi, Yasushi
    Shimizu, Wataru
    [J]. IJC HEART & VASCULATURE, 2021, 33
  • [4] ABLATION CATHETER IMPEDANCE DECREASES IN THE PULMONARY VEIN AND LEFT ATRIUM DURING AN ATRIAL FIBRILLATION ABLATION PROCEDURE
    Cromie, N. A.
    Sultan, O.
    Agarwal, S.
    Ayou, R.
    Chen, L.
    Novak, P.
    Sterns, L. D.
    Leather, R.
    Tang, A. S.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 : 89D - 90D
  • [5] The Effectiveness and Safety of the Esophageal Temperature Monitoring During Catheter Ablation of Atrial Fibrillation
    Ito, Miwa
    Kanazawa, Hisanori
    Hoshiyama, Tadashi
    Kawahara, Yusei
    Tsujita, Kenichi
    [J]. CIRCULATION, 2020, 142
  • [6] Combined contact force and local impedance dynamics during repeat atrial fibrillation catheter ablation
    Alken, Fares-Alexander
    Scherschel, Katharina
    Kahle, Ann-Kathrin
    Masjedi, Mustafa
    Meyer, Christian
    [J]. FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [7] Visualization of the Esophagus During Catheter Ablation of Atrial Fibrillation
    Burr Hall
    Abrar Shah
    David Huang
    Spencer Rosero
    James Daubert
    [J]. Journal of Interventional Cardiac Electrophysiology, 2005, 13 : 135 - 137
  • [8] Visualization of the esophagus during catheter ablation of atrial fibrillation
    Hall, B
    Shah, A
    Huang, D
    Rosero, S
    Daubert, J
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2005, 13 (02) : 135 - 137
  • [9] Radiation exposure during catheter ablation of atrial fibrillation
    Lickfett, L
    Mahesh, M
    Vasamreddy, C
    Bradley, D
    Jayam, V
    Eldadah, Z
    Dickfeld, T
    Kearney, D
    Dalal, D
    Lüderitz, B
    Berger, R
    Calkins, H
    [J]. CIRCULATION, 2004, 110 (19) : 3003 - 3010
  • [10] Protection of the esophagus during catheter ablation of atrial fibrillation
    Houmsse, Mahmoud
    Daoud, Emile G.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (10) : 2824 - 2829