Nonlinear static and dynamic behaviors assessment of self-centering post-tensioned concrete wall with multiple-slit device

被引:6
|
作者
Moghaddam, Sina Heyrani [1 ]
Shooshtari, Ahmad [1 ]
机构
[1] Ferdowsi Univ Mashhad, Engn Fac, Dept Civil Engn, Mashhad, Razavi Khorasan, Iran
来源
关键词
Self-centering system; Post-tensioned concrete wall; Energy dissipators bars; Multiple-slit device; Nonlinear seismic analysis; OpenSees software; SEISMIC BEHAVIOR; DESIGN; PERFORMANCE;
D O I
10.1016/j.jobe.2021.102999
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Conventional seismic force-resisting systems usually experience significant structural damage, and repairing such buildings is not economical. A new type of seismic force-resisting system is self-centering Post-Tensioned Concrete Wall (PT-CW), in which vertical Post-Tensioned (PT) cables supply the return force of the structure to its initial state. This study is dedicated to investigate the seismic behavior of the self-centering PT-CW system using nonlinear static, cyclic, and response history analyses. The loading and design of the studied buildings are performed in the 3D model, then one of the frames is selected and the nonlinear analyses are done in OpenSees software. In order to increase the absorption energy of PT-CW, a Multi-Slit Device (MSD) is employed. For this purpose, three systems including PT-CW with Energy Dissipators (ED) bars, PT-CW with MSD, and traditional Concrete Shear Wall (CSW) are modeled in Opensees software. These seismic force-resisting systems are applied into three, six, and ten-story buildings. To validate the proposed models, the results of an experimental study are applied. Then, the nonlinear responses of the introduced models are numerically obtained as well. Accordingly, the PT-CW with MSD has more ductility and less strength drop than the other two systems. Finally, ten far-field earthquake records are selected and scaled with the ASCE spectrum to implement NRH analysis. As a result, it is observed that the story drift of the PT-CW with MSD under the applied earthquake records is almost uniform and less than the PT-CW with ED bars.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] ENERGY DISSIPATION IN POST-TENSIONED SELF-CENTERING PRECAST CONCRETE CONNECTIONS WITH A FRICTION DEVICE
    Koshikawa, Takeaki
    IMPLEMENTING INNOVATIVE IDEAS IN STRUCTURAL ENGINEERING AND PROJECT MANAGEMENT, 2015, : 31 - 36
  • [2] Self-Centering Behavior of Unbonded, Post-Tensioned Precast Concrete Shear Walls
    Erkmen, Bulent
    Schultz, Arturo E.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2009, 13 (07) : 1047 - 1064
  • [3] Performance-based earthquake engineering assessment of a self-centering, post-tensioned concrete bridge system
    Lee, Won K.
    Billington, Sarah L.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2011, 40 (08): : 887 - 902
  • [4] Modeling of force-displacement behavior of post-tensioned self-centering concrete connections
    Li, Lu-Xi
    Li, Hong-Nan
    Li, Chao
    Yang, Yeong-Bin
    Zhang, Cai-Yan
    ENGINEERING STRUCTURES, 2019, 198
  • [5] Self-centering links using post-tensioned composite tendons
    Xu, Xian
    Zheng, Yanfeng
    Luo, Yaozhi
    ADVANCES IN STRUCTURAL ENGINEERING, 2018, 21 (09) : 1302 - 1312
  • [6] Column restraint in post-tensioned self-centering moment frames
    Chou, Chung-Che
    Chen, Jun-Hen
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (07): : 751 - 774
  • [7] Numerical modeling to predict seismic performance of the post-tensioned self-centering concrete shear walls
    Liu, Yang
    Zhou, Wei
    BULLETIN OF EARTHQUAKE ENGINEERING, 2022, 20 (02) : 1057 - 1086
  • [8] Numerical modeling to predict seismic performance of the post-tensioned self-centering concrete shear walls
    Yang Liu
    Wei Zhou
    Bulletin of Earthquake Engineering, 2022, 20 : 1057 - 1086
  • [9] Seismic performance of self-centering connections with steel beams post-tensioned to a reinforced concrete column
    Department of Civil Engineering, National Chiao Tung University, Hsinchu, 30010, Taiwan
    Journal of the CICHE, 2007, 3 (425-437):
  • [10] Experimental study on behaviors of beam-column connections for self-centering post-tensioned precast frame
    Cai, Xiaoning
    Meng, Shaoping
    Sun, Weiwei
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2012, 45 (12): : 29 - 37