Fixed mounted infrared 2D and line cameras for industrial non-contact temperature measurement

被引:0
|
作者
Drögmöller, P
Budzier, H
Hofmann, G
Krause, V
Reichardt, T
Vollheim, B
Vollheim, J
Gerlach, G
机构
来源
THERMOSENSE XXV | 2003年 / 5073卷
关键词
IR 2D cameras; IR line cameras; uncooled IR arrays; pyroelectric arrays; microbolometer arrays; InGaAs arrays; non-contact temperature measurement;
D O I
10.1117/12.485875
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
New uniform camera electronics were developed for different stationary line and 2D infrared cameras for non-contact temperature measurement. The 16bit analog/digital converter used enables a maximum pixel rate of 10 MHz. The electronics are based on a System Of Programmable Chip (SOPC) solution using a PLD with an embedded processor. The ability to reprogram the PLD allows an inexpensive adaptation to different sensor types and various industrial applications. The embedded processor executes the signal processing. In addition, the embedded processor controls and monitors the camera head, monitors the operation of the chopper/shutter motor and internal temperature sensors, and can be used to control a number of functions such as triggering or frame rate. The PC communicates with the microcontroller via an asynchronous interface. The other essential components of the digital signal-processing unit include a serializer, a flash memory and a SRAM. The new 16bit camera electronics have been incorporated into the 2D infrared cameras PYROVIEW 256 with a pyroelectric array (256 x 128 pixel) and PYROVIEW 320 with a microbolometer array (320 x 240 pixel). In addition the newly developed 16bit camera electronics also provide the basis for faster line cameras PYROLINE 256 with pyroelectric arrays of 256 x 1 and HZK 256 with an InGaAs linear array of 256 x 1.
引用
收藏
页码:41 / 50
页数:10
相关论文
共 50 条
  • [21] OPTIMUM ALGORITHM OF INFRARED DEFECTOSCOPY IN CASE OF NON-CONTACT TEMPERATURE-MEASUREMENT
    TIKHOMIROV, VA
    TROITSKII, IN
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1977, 13 (01): : 55 - 59
  • [22] Performance characterization of non-contact infrared thermometers (NCITs) for forehead temperature measurement
    Sullivan, Stacey J. L.
    Seay, Nathanael
    Zhu, Liang
    Rinaldi, Jean E.
    Hariharan, Prasanna
    Vesnovsky, Oleg
    Topoleski, L. D. Timmie
    MEDICAL ENGINEERING & PHYSICS, 2021, 93 : 93 - 99
  • [23] A micro sensor for non-contact temperature measurement
    Li, XP
    Chan, WF
    MICROMACHINING AND MICROFABRICATION, 2000, 4230 : 66 - 75
  • [24] Non-contact measurement of pulse wave velocity using RGB cameras
    Nakano, Kazuya
    Aoki, Yuta
    Satoh, Ryota
    Hoshi, Akira
    Suzuki, Hiroyuki
    Nishidate, Izumi
    OPTICAL DIAGNOSTICS AND SENSING XVI: TOWARD POINT-OF-CARE DIAGNOSTICS, 2016, 9715
  • [25] Non-contact high temperature strain measurement
    Wang, Shurong
    Li, Zhigang
    Guangxue Xuebao/Acta Optica Sinica, 1998, 18 (12): : 1760 - 1764
  • [26] Reduction of uncertainty with non-contact measurement of temperature
    Zakharenko, V. A.
    Veprikova, Ya R.
    Ponomarev, D. B.
    XII INTERNATIONAL SCIENTIFIC AND TECHNICAL CONFERENCE APPLIED MECHANICS AND SYSTEMS DYNAMICS, 2019, 1210
  • [27] Non-contact temperature measurement by laser technology
    Huang, Fang
    Liu, Xiangxin
    Han, Junfeng
    Wang, Jing
    Li, Hui
    Wang, Wenjing
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2013, 33 (07): : 642 - 646
  • [28] Non-contact temperature measurement in embedded applications
    Ibrahim, Dogan
    ELECTRONICS WORLD, 2017, 123 (1971): : 14 - 16
  • [29] Comparison of Non-contact Infrared Temperature with Digital Axillary Temperature
    Varghese Abraham
    Elizabeth Johnson
    Khristina Deep
    Indian Pediatrics, 2018, 55 : 609 - 610
  • [30] Comparison of Non-contact Infrared Temperature with Digital Axillary Temperature
    Abraham, Varghese
    Johnson, Elizabeth
    Deep, Khristina
    INDIAN PEDIATRICS, 2018, 55 (07) : 609 - 610