Nonlinear rooftop tuned mass damper frame for the seismic retrofit of buildings

被引:16
|
作者
Johnson, Jerod G. [1 ]
Pantelides, Chris P. [1 ]
Reaveley, Lawrence D. [1 ]
机构
[1] Univ Utah, Dept Civil & Environm Engn, Salt Lake City, UT 84112 USA
来源
关键词
buckling restrained brace; damper; earthquakes; nonlinear; period shift; retrofit; rooftop;
D O I
10.1002/eqe.2473
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Numerical studies of existing buildings demonstrate the effectiveness of nonlinear/inelastic rooftop tuned mass damper frames (NRTMDF) used as a retrofit for reducing seismic response. The technique utilizes a rooftop penthouse as a tuned mass damper with mass incorporated as the roof deck of the penthouse while targeted nonlinearity and energy dissipation are introduced through buckling restrained braces (BRBs) linking the penthouse mass to the structure below. The writers summarize numerical studies of ten existing buildings modified with a specifically tuned NRTMDF. The studies demonstrate the effectiveness of the technique that stems from elastic and transient inelastic period shifts enabled by the damper coupled with targeted energy dissipation in the penthouse BRBs. Numerical simulations using response nonlinear time-history analysis techniques show that for many structures and sites, the NRTMDF decreases peak transient response and overall seismic demand of the original structure. The technique also reduces seismic demand on nonstructural elements and components, manifested as reductions in floor acceleration spectra. Energy methods show that the approach enables significant reductions in energy demand on the original structure through the complete earthquake acceleration history. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:299 / 316
页数:18
相关论文
共 50 条
  • [21] Adaptive Passive Negative Stiffness and Damping for Retrofit of Existing Tall Buildings with Tuned Mass Damper: TMD-NSD
    Wang, Meng
    Nagarajaiah, Satish
    Chen, Lin
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (11)
  • [22] Inerter-Connected Double Tuned Mass Damper for Passive Control of Buildings under Seismic Excitation
    Jalali, Himan Hojat
    Farzam, Maziar Fahimi
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2022, 66 (02): : 421 - 432
  • [23] Experimental investigation of vibration attenuation using nonlinear tuned mass damper and pendulum tuned mass damper in parallel
    Sun, C.
    Nagarajaiah, S.
    Dick, A. J.
    NONLINEAR DYNAMICS, 2014, 78 (04) : 2699 - 2715
  • [24] Experimental investigation of vibration attenuation using nonlinear tuned mass damper and pendulum tuned mass damper in parallel
    C. Sun
    S. Nagarajaiah
    A. J. Dick
    Nonlinear Dynamics, 2014, 78 : 2699 - 2715
  • [25] Comparative Studies on Nonlinear Structures with Multiple Tuned Mass Damper and Multiple Tuned Impact Damper
    Lu, Zheng
    Zhou, Mengyao
    Ma, Naiyin
    Du, Jiang
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2023, 23 (14)
  • [26] A bidirectional tuned liquid column damper for reducing the seismic response of buildings
    Rozas, Luis
    Boroschek, Ruben L.
    Tamburrino, Aldo
    Rojas, Matias
    STRUCTURAL CONTROL & HEALTH MONITORING, 2016, 23 (04): : 621 - 640
  • [27] Optimization of Tuned Mass Damper for Adjacent Buildings with Equal Properties
    Bekdas, Gebrail
    Nigdeli, Sinan Melih
    11TH INTERNATIONAL CONFERENCE OF NUMERICAL ANALYSIS AND APPLIED MATHEMATICS 2013, PTS 1 AND 2 (ICNAAM 2013), 2013, 1558 : 429 - 432
  • [28] Wind response control of tall buildings with a tuned mass damper
    Elias, Said
    Matsagar, Vasant
    JOURNAL OF BUILDING ENGINEERING, 2018, 15 : 51 - 60
  • [29] Control of Adjacent Buildings Using Shared Tuned Mass Damper
    Guenidi, Z.
    Abdeddaim, M.
    Ounis, A.
    Shrimali, M. K.
    Datta, T. K.
    X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 1568 - 1573
  • [30] Probabilistic seismic assessment and retrofit considerations for Italian RC frame buildings
    Gerard J. O’Reilly
    Timothy J. Sullivan
    Bulletin of Earthquake Engineering, 2018, 16 : 1447 - 1485