Chilled Coil Performance Control and Application to Turbine Inlet Air Cooling

被引:1
|
作者
Anand, Gopalakrishnan [1 ]
Makar, Ellen [1 ]
机构
[1] Energy Concepts Co, 627 Ridgely Ave, Annapolis, MD 21401 USA
关键词
Turbine inlet air cooling; chilling coil; TIAC; ammonia water absorption; absorption chilling; controls; OPTIMIZING DESIGN;
D O I
10.1142/S2010132521500164
中图分类号
O414.1 [热力学];
学科分类号
摘要
The Absorption Refrigeration Cycle Turbine Inlet Conditioning (ARCTIC) system can chill the inlet air of the turbine to maintain optimum turbine performance at all ambient temperatures. However, turbine characteristics and bell-mouth icing concerns impose a minimum temperature limitation on the chilled air. Performance guarantees may also require maintaining the inlet air temperature within a narrow range throughout the year. These considerations require accurate prediction of the chilling coil performance over a wide range of operating conditions and the development of a robust controls strategy. A modified wet-surface model is used to model the chilling coil performance. The application of the model to a 2110kW (600 RT) ARCTIC providing inlet air chilling for a MARS 100 turbine is considered. A control strategy is developed to maintain the inlet air temperature at the desired set point with varying ambient temperatures and chilling loads. The TIAC controls help maintain the inlet air temperature at 7.22(degrees)C to maximize turbine capacity and efficiency during most of the hot/warm days and accommodates 100% turndown. Additional safety measures are incorporated to prevent bell-mouth icing.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Thermodynamic assessment of impact of inlet air cooling techniques on gas turbine and combined cycle performance
    Mohapatra, Alok Ku
    Sanjay
    ENERGY, 2014, 68 : 191 - 203
  • [32] Augmentation of gas turbine performance using integrated EAHE and Fogging Inlet Air Cooling System
    Barakat, S.
    Ramzy, Ahmed
    Hamed, A. M.
    El-Emam, S. H.
    ENERGY, 2019, 189
  • [33] A simplified explicit model for determining the performance of a chilled water cooling coil
    Lee, C. K.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 43 : 167 - 175
  • [34] Design of a Heat Exchanger for Gas Turbine Inlet Air using Chilled Water System
    Karim, Z. A. Abdul
    Azmi, M. N. H. Mohd
    Abdullah, A. S.
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 1689 - 1694
  • [35] Performance Analysis of Gas Turbine Inlet Air Cooling Plant with Hybrid Indirect Evaporative Cooling and Absorption Chiller System
    Hamedani, Amir Moradi
    Salehi, Gholamreza
    Masoomi, Mina
    Manesh, Mohammad Hasan Khoshgoftar
    INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2021, 24 (03) : 248 - 259
  • [36] Benefits of compressor inlet air cooling for gas turbine cogeneration plants
    DeLucia, M
    Lanfranchi, C
    Boggio, V
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 598 - 603
  • [37] Inlet air cooling methods for gas turbine based power plants
    Kakaras, E
    Doukelis, A
    Prelipceanu, A
    Karellas, S
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2006, 128 (02): : 312 - 317
  • [38] Combustion turbine inlet air cooling - Check your design point
    Kraft, JE
    POWER ENGINEERING, 2004, 108 (05) : 40 - +
  • [39] Two-Stage Evaporative Inlet Air Gas Turbine Cooling
    Zeitoun, Obida
    ENERGIES, 2021, 14 (05)
  • [40] Systematic assessment of combustion turbine inlet air-cooling techniques
    Al-Amiri, AM
    Zamzam, MM
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2005, 127 (01): : 159 - 169