Fundus imaging in newborn children with wide-field scanning laser ophthalmoscope

被引:8
|
作者
Magnusdottir, Vigdis [1 ,2 ]
Vehmeijer, Wouter B. [3 ]
Eliasdottir, Thorunn S. [1 ]
Hardarson, Sveinn H. [1 ]
Schalij-Delfos, Nicoline E. [3 ]
Stefansson, Einar [1 ]
机构
[1] Univ Iceland, Landspitali Univ Hosp, Dept Ophthalmol, Reykjavik, Iceland
[2] Oslo Univ Hosp, Dept Ophthalmol, Oslo, Norway
[3] Leiden Univ, Leiden Univ Med Ctr, Dept Ophthalmol, Leiden, Netherlands
关键词
eye speculum; infants; mydriatics; retina; scanning laser ophthalmoscope; wide-field images; DIABETIC-RETINOPATHY; PREMATURITY; ANGIOGRAPHY; OPTOMAP;
D O I
10.1111/aos.13453
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeCurrent fundus imaging in newborn babies requires mydriatics, eye specula and corneal contact. We propose that a scanning laser ophthalmoscope (SLO) allows ultra wide-field imaging with reduced stress for the child. MethodsThis prospective observational single centre study was conducted in Landspitali, University Hospital, Reykjavik, Iceland. In this study, a noncontact wide-field SLO (Optomap 200Tx) was used to image the retina in healthy full-term newborns without the use of mydriatics or eye specula. The child was held by one of the parents, while one of the researchers supported the child's head in front of the SLO camera for alignment and opened the eye with either a finger or a cotton tip. ResultsFifty-nine participants were recruited (34 females). The mean age was 16days, and the mean gestational age was 401weeks at the time of imaging. Ultra-wide-field (200 degrees) images were obtained of 44 participants. Twenty-seven participants (61%) had at least one ultra wide-field image with the optic disc and vessel segments in all quadrants of the fundus visible and in focus. No retinal pathology was found in the participants with the exception of one participant with small retinal haemorrhages. ConclusionScanning laser ophthalmoscope (SLO) ultra-wide-field fundus imaging is feasible in healthy full-term newborns without corneal contact, eye speculum or mydriatics. This approach could be an improvement for retinal imaging in newborn infants. Eye movement of the infant, whether asleep or awake, influenced which part of the fundus was captured, but focus and image quality were generally good.
引用
收藏
页码:842 / 844
页数:3
相关论文
共 50 条
  • [1] Wide-field scanning laser ophthalmoscope imaging in newborn children
    Magnusdottir, Vigdis
    Vehmeijer, Wouter
    Hardarson, Sveinn Hakon
    Eliasdottir, Thorunn Scheving
    Schalij-Delfos, Nicoline E.
    Stefansson, Einar
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [2] Wide-field retinal hemodynamic imaging with the tracking scanning laser ophthalmoscope
    Ferguson, RD
    Hammer, DX
    Elsner, AE
    Webb, RH
    Burns, SA
    OPTICS EXPRESS, 2004, 12 (21): : 5198 - 5208
  • [3] Evaluation of fundus autofluorescence in retinitis pigmentosa using ultra wide-field scanning laser ophthalmoscope
    Shimoda, Yukitoshi
    Kishi, Shoji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [4] Adaptive optics scanning laser ophthalmoscope with integrated wide-field retinal imaging and tracking
    Ferguson, R. Daniel
    Zhong, Zhangyi
    Hammer, Daniel X.
    Mujat, Mircea
    Patel, Ankit H.
    Deng, Cong
    Zou, Weiyao
    Burns, Stephen A.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2010, 27 (11) : A265 - A277
  • [5] Wide-Field Scanning Laser Ophthalmoscope Imaging and Angiography of Central Retinal Vein Occlusion
    Kernt, Marcus
    Ulbig, Michael W.
    CIRCULATION, 2010, 121 (12) : 1459 - 1460
  • [6] Wide-field stabilized Doppler flowmetry with the tracking scanning laser ophthalmoscope (TSLO)
    Ferguson, RD
    Hammer, DX
    Elsner, AE
    Burns, SA
    Webb, RH
    Weiter, JJ
    OPHTHALMIC TECHNOLOGIES XIV, 2004, 5314 : 170 - 178
  • [7] Quantification of the Image Obtained With a Wide-Field Scanning Ophthalmoscope
    Oishi, Akio
    Hidaka, Jiro
    Yoshimura, Nagahisa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (04) : 2424 - 2431
  • [8] Quantification of the image obtained with wide-field scanning ophthalmoscope
    Oishi, Akio
    Hidaka, Jiro
    Yoshimura, Nagahisa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [9] DIGITAL FUNDUS IMAGING USING A SCANNING LASER OPHTHALMOSCOPE
    MANIVANNAN, A
    SHARP, PF
    PHILLIPS, RP
    FORRESTER, JV
    PHYSIOLOGICAL MEASUREMENT, 1993, 14 (01) : 43 - 56
  • [10] CONFOCAL IMAGING OF THE FUNDUS USING A SCANNING LASER OPHTHALMOSCOPE
    WOON, WH
    FITZKE, FW
    BIRD, AC
    MARSHALL, J
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (08) : 470 - 474