Elastic flexural buckling of non-uniform members: Closed-form expression and equivalent load approach

被引:19
|
作者
Serna, M. A. [1 ]
Ibanez, J. R. [1 ]
Lopez, A. [2 ]
机构
[1] Univ Cantabria, Dept Struct Engn, E-39005 Santander, Spain
[2] Univ Navarra, Tecnun, San Sebastian 20018, Spain
关键词
Flexural buckling; Non-uniform members; COLUMNS; COMPUTATION; STIFFNESS; LENGTH;
D O I
10.1016/j.jcsr.2011.01.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Experienced structural engineers have an intuitive understanding of the buckling behavior of uniform members subjected to compressive loads. The Euler critical load and the concept of buckling length are extensively used in this context. Unfortunately, the extension of this intuitive approach to cases with non-uniform load or non-uniform members is not straightforward. Based on an extensive numerical parametric study, the paper first presents a closed-form expression for the buckling load of constant cross-section members with non-uniform axial loading. Consequently, an equivalent load approach for non-uniform members subjected to non-uniform axial load distribution is proposed and validated. The combination of both procedures has the power of transforming the general complex case of a non-uniform member under non-uniform load into an equivalent simple case of a uniform member subjected to uniform load. The new methodology is simple and direct, and produces more than acceptable approximate results. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1078 / 1085
页数:8
相关论文
共 50 条
  • [21] Closed-form methodology for stress analysis of composite plates with cutouts and non-uniform lay-up
    Pastorino, D.
    Blazquez, A.
    Lopez-Romano, B.
    Paris, F.
    COMPOSITE STRUCTURES, 2019, 212 : 389 - 397
  • [22] Closed-Form Critical Buckling Load of Simply Supported Orthotropic Plates and Verification
    Jing, Zhao
    Sun, Qin
    Liang, Ke
    Chen, Jianqiao
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2019, 19 (12)
  • [23] Buckling length of non-uniform members under stepped axial loads
    Civil Engineering Department, Lab. Metal Struct., Natl. Tech. U., Athens, Greece
    Comput Struct, 6 (573-582):
  • [24] Buckling length of non-uniform members under stepped axial loads
    Ermopoulos, JC
    COMPUTERS & STRUCTURES, 1999, 73 (06) : 573 - 582
  • [25] A Non-Closed-Form Mathematical Model for Uniform and Non-Uniform Distributed Amplifiers
    El Chaar, Mohamad
    de Souza, Antonio Lisboa
    Barragan, Manuel
    Podevin, Florence
    Bourdel, Sylvain
    2020 IEEE MTT-S INTERNATIONAL CONFERENCE ON MICROWAVES FOR INTELLIGENT MOBILITY (ICMIM), 2020,
  • [26] Branched flows of flexural elastic waves in non-uniform cylindrical shells
    Jose, Kevin
    Ferguson, Neil
    Bhaskar, Atul
    PLOS ONE, 2023, 18 (05):
  • [27] An exact closed-form explicit solution of free transverse vibration for non-uniform multi-cracked beam
    Jazi, Shahram Hadian
    Hadian, Mostafa
    Torabi, Keivan
    JOURNAL OF SOUND AND VIBRATION, 2024, 570
  • [28] Closed-form methodology for the structural analysis of stiffened composite plates with cutouts and non-uniform lay-up
    Blazquez, A.
    Pastorino, D.
    Lopez-Romano, B.
    Paris, F.
    COMPOSITE STRUCTURES, 2024, 343
  • [29] The closed-form solution for the forced vibration of non-uniform plates with distributed time-dependent boundary conditions
    Lin, SM
    JOURNAL OF SOUND AND VIBRATION, 2000, 232 (03) : 493 - 509
  • [30] Closed-Form Capacity Expression for Low Complexity BICM with Uniform Inputs
    Nissel, Ronald
    Caban, Sebastian
    Rupp, Markus
    2015 IEEE 26TH ANNUAL INTERNATIONAL SYMPOSIUM ON PERSONAL, INDOOR, AND MOBILE RADIO COMMUNICATIONS (PIMRC), 2015, : 678 - 682