Non-invasive measurement of bioelectric currents with a vibrating probe

被引:104
|
作者
Reid, Brian [1 ]
Nuccitelli, Richard [2 ]
Zhao, Min [1 ]
机构
[1] Univ Aberdeen, Sch Med Sci, Aberdeen AB25 2ZD, Scotland
[2] BioElectroMed Corp, Norfolk, VA 23510 USA
基金
英国惠康基金;
关键词
D O I
10.1038/nprot.2007.91
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Small d.c. electrical signals have been detected in many biological systems and often serve important functions in cells and organs. For example, we have recently found that they play a far more important role in directing cell migration in wound healing than previously thought. Here, we describe the manufacture and use of a simplified ultrasensitive vibrating probe system for measuring extracellular electrical currents. This vibrating probe is an insulated, sharpened metal wire with a small platinum-black tip (10-30 mu m), which can detect ionic currents in the mu A cm(-2) range in physiological saline. The probe is vibrated at about 300 Hz by a piezoelectric bender. In the presence of an ionic current, the probe detects a voltage difference between the extremes of its movement. The basic, low-cost system we describe is readily adaptable to most laboratories interested in measuring physiological electric currents associated with wounds, developing embryos and other biological systems.
引用
收藏
页码:661 / 669
页数:9
相关论文
共 50 条
  • [31] Invasive and non-invasive measurement in medicine and biology: calibration issues
    Rolfe, P.
    Zhang, Yan
    Sun, Jinwei
    Scopesi, F.
    Serra, G.
    Yamakoshi, K.
    Tanaka, S.
    Yamakoshi, T.
    Yamakoshi, Y.
    Ogawa, M.
    6TH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2010, 7544
  • [32] Non-Invasive Measurement of Trust in Group Interactions
    Spitzley, Lee A.
    Wang, Xinran
    Chen, Xunyu
    Pentland, Steven J.
    Nunamaker, Jay F.
    Burgoon, Judee K.
    Dunbar, Norah E.
    IEEE TRANSACTIONS ON AFFECTIVE COMPUTING, 2023, 14 (03) : 2389 - 2401
  • [33] Non-invasive Measurement of Hemoglobin Content in Blood
    Nirupa, Lourdes Albina J.
    Kumar, Jagadeesh, V
    2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 638 - 642
  • [34] NON-INVASIVE MEASUREMENT OF STATIC LUNG COMPLIANCE
    TOBIN, MJ
    JENOURI, G
    WATSON, H
    SACKNER, MA
    FEDERATION PROCEEDINGS, 1982, 41 (05) : 1625 - 1625
  • [35] NON-INVASIVE MEASUREMENT OF TEMPERATURE IN ULTRASONIC HYPERTHERMIA
    SINGH, VR
    YADAV, S
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 850 - 851
  • [36] Non-invasive prenatal measurement of the fetal genome
    Fan, H. Christina
    Gu, Wei
    Wang, Jianbin
    Blumenfeld, Yair J.
    El-Sayed, Yasser Y.
    Quake, Stephen R.
    NATURE, 2012, 487 (7407) : 320 - +
  • [37] Non-invasive measurement of airway inflammation in asthma
    Menzies, Daniel
    Nair, Arun
    Lipworth, Brian J.
    JOURNAL OF ASTHMA, 2006, 43 (06) : 407 - 415
  • [38] Non-invasive measurement of the human core temperature
    Steck, Luke N.
    Sparrow, Ephraim M.
    Abraham, John P.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (04) : 975 - 982
  • [39] Non-invasive measurement of proppant pack deformation
    Walsh, Stuart D. C.
    Smith, Megan
    Carroll, Susan A.
    Crandall, Dustin
    INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 2016, 87 : 39 - 47
  • [40] Non-invasive prenatal measurement of the fetal genome
    H. Christina Fan
    Wei Gu
    Jianbin Wang
    Yair J. Blumenfeld
    Yasser Y. El-Sayed
    Stephen R. Quake
    Nature, 2012, 487 : 320 - 324