Non-invasive measurement of bioelectric currents with a vibrating probe

被引:104
|
作者
Reid, Brian [1 ]
Nuccitelli, Richard [2 ]
Zhao, Min [1 ]
机构
[1] Univ Aberdeen, Sch Med Sci, Aberdeen AB25 2ZD, Scotland
[2] BioElectroMed Corp, Norfolk, VA 23510 USA
基金
英国惠康基金;
关键词
D O I
10.1038/nprot.2007.91
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Small d.c. electrical signals have been detected in many biological systems and often serve important functions in cells and organs. For example, we have recently found that they play a far more important role in directing cell migration in wound healing than previously thought. Here, we describe the manufacture and use of a simplified ultrasensitive vibrating probe system for measuring extracellular electrical currents. This vibrating probe is an insulated, sharpened metal wire with a small platinum-black tip (10-30 mu m), which can detect ionic currents in the mu A cm(-2) range in physiological saline. The probe is vibrated at about 300 Hz by a piezoelectric bender. In the presence of an ionic current, the probe detects a voltage difference between the extremes of its movement. The basic, low-cost system we describe is readily adaptable to most laboratories interested in measuring physiological electric currents associated with wounds, developing embryos and other biological systems.
引用
收藏
页码:661 / 669
页数:9
相关论文
共 50 条
  • [1] Non-invasive measurement of bioelectric currents with a vibrating probe
    Brian Reid
    Richard Nuccitelli
    Min Zhao
    Nature Protocols, 2007, 2 : 661 - 669
  • [2] Measurement of Bioelectric Current with a Vibrating Probe
    Reid, Brian
    Zhao, Min
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2011, (47):
  • [3] VIBRATING PROBE ELECTROMETER FOR THE MEASUREMENT OF BIOELECTRIC POTENTIALS
    BLUH, O
    SCOTT, BIH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1950, 21 (10): : 867 - 868
  • [4] Non-invasive measurement of chip currents in IGBT modules
    Palmer, PR
    Stark, BH
    Joyce, JC
    PESC'97: 28TH ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE - RECORD, VOLS I AND II, 1997, : 166 - 171
  • [5] Non-Invasive Integrated Light Probe
    Grillanda, S.
    Morichetti, F.
    Carminati, M.
    Ferrari, G.
    Strain, M. J.
    Sorel, M.
    Sampietro, M.
    Melloni, A.
    2014 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2014,
  • [6] NON-INVASIVE MEASUREMENT OF MATURITY
    ROCHE, AF
    TYLESHEVSKI, F
    ROGERS, E
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1983, 60 (02) : 246 - 246
  • [7] Non-Invasive Measurement of Stress
    Yildiz, Sedat
    ACTA PHYSIOLOGICA, 2015, 215 : 12 - 13
  • [8] Use of a laser beam probe for the non-invasive measurement of signals in silicon ICs
    DeVenuto, D
    Corsi, F
    JOINT CONFERENCE - 1996: IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE & IMEKO TECHNICAL COMMITTEE 7, CONFERENCE PROCEEDINGS, VOLS I AND II: QUALITY MEASUREMENTS: THE INDISPENSABLE BRIDGE BETWEEN THEORY AND REALITY (NO MEASUREMENTS? NO SCIENCE!), 1996, : 1050 - 1055
  • [9] NON-INVASIVE MEASUREMENT OF TISSUE BLOOD-FLOW WITH A DOPPLER-LASER PROBE
    TRICOT, P
    BENICHOUX, R
    ZEMZAMI, A
    BERGHEAU, JM
    GROLLIER, M
    EUROPEAN SURGICAL RESEARCH, 1982, 14 (02) : 142 - 142
  • [10] Non-invasive measurement of tumor oxygenation using embedded microparticulate EPR spin probe
    Ilangovan, G
    Bratasz, A
    Kuppusamy, P
    OXYGEN TRANSPORT TO TISSUE XXVI, 2005, 566 : 67 - 73