Flow-through amperometric determination of ampicillin using a copper electrode in a batch injection analysis system

被引:21
|
作者
Veloso, William Barros [1 ]
Correa Ribeiro, Geyse Adriana [1 ]
da Rocha, Claudia Quintino [1 ]
Tanaka, Auro Atsushi [1 ,3 ]
da Silva, Iranaldo Santos [2 ]
Ferreira Dantas, Luiza Maria [2 ]
机构
[1] Univ Fed Maranhao, Ctr Ciencias Exatas & Tecnol, Dept Quim, BR-65080805 Sao Luis, Maranhao, Brazil
[2] Univ Fed Maranhao, Ctr Ciencias Exatas & Tecnol, Dept Tecnol Quim, BR-65080805 Sao Luis, Maranhao, Brazil
[3] Inst Nacl Ciencia & Tecnol Bioanalit, Caixa Postal 6154, BR-13083970 Campinas, SP, Brazil
关键词
Ampicillin; Batch injection analysis; Copper electrode; Rapid determination; LACTAM ANTIBIOTICS; ACID; PENICILLINS; AMOXICILLIN; SAMPLES;
D O I
10.1016/j.measurement.2020.107516
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents, for the first time, an amperometric electroanalytical method for ampicillin determination using a copper electrode in a batch injection analysis (BIA) system. Initial voltammetric measurements were performed to establish the working potential in the amperometric assays and to optimize parameters such as the supporting electrolyte and the pH of the medium. The method was shown to be precise (RSD = 3.5%, n = 18), reliable (confirmed by an application using a drug sample), sensitive (LOD = 7.11 mu mol L-1; LOQ = 23.7 mu mol L-1), and fast (86 injections h(-1)). The proposed method was successfully applied for the determination of ampicillin in commercial drug samples. The results were compared with those obtained using HPLC-UV/Vis and UV-Vis spectrophotometry. There were no significant differences, indicating that the new technique could be used in routine analyses. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Modelling dynamics of amperometric biosensors in batch and flow injection analysis
    Baronas, R
    Ivanauskas, F
    Kulys, J
    JOURNAL OF MATHEMATICAL CHEMISTRY, 2002, 32 (02) : 225 - 237
  • [32] Modelling Dynamics of Amperometric Biosensors in Batch and Flow Injection Analysis
    R. Baronas
    F. Ivanauskas
    J. Kulys
    Journal of Mathematical Chemistry, 2002, 32 : 225 - 237
  • [33] FLOW-THROUGH SANDWICH PVC MATRIX MEMBRANE-ELECTRODE FOR FLOW-INJECTION ANALYSIS
    ALEGRET, S
    ALONSO, J
    BARTROLI, J
    LIMA, JLFC
    MACHADO, AASC
    PAULIS, JM
    ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (18): : 2291 - 2303
  • [34] FLOW-INJECTION ANALYSIS OF TRACE FREE CYANIDE IN SURFACE GROUND WATERS WITH AN AMPEROMETRIC FLOW-THROUGH DETECTOR
    MA, HC
    JIN, L
    YAN, HY
    KEXUE TONGBAO, 1983, 28 (08): : 1145 - 1145
  • [35] Amperometric determination of omeprazole on screen-printed electrodes using batch injection analysis
    Stefano, Jessica S.
    Tormin, Thiago F.
    da Silva, Jamilia P.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    MICROCHEMICAL JOURNAL, 2017, 133 : 398 - 403
  • [36] Potentiometric Determination of Sibutramine Using Batch and Flow Injection Analysis
    El Gohary, Nesrine A.
    El Nashar, Rasha M.
    Aboul-Enien, Hassan Y.
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 241 - 257
  • [37] CHARACTERISTICS OF AN AMPEROMETRIC FLOW-THROUGH DETECTOR WITH A RENEWABLE STATIONARY MERCURY-ELECTRODE
    BALTENSPERGER, U
    EGGLI, R
    ANALYTICA CHIMICA ACTA, 1981, 123 (JAN) : 107 - 114
  • [38] Voltammetric and flow injection amperometric determination of cysteine at a glassy carbon electrode in the presence of Copper(II) ions
    Dursun, Z
    Sahbaz, I
    Ertas, FN
    Nisli, G
    TURKISH JOURNAL OF CHEMISTRY, 2003, 27 (04) : 513 - 519
  • [39] DETERMINATION OF MITOXANTRONE BY FLOW-INJECTION ANALYSIS USING AN AMPEROMETRIC DETECTOR
    VILLAR, JCC
    GARCIA, AC
    BLANCO, PT
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (04) : 263 - 267
  • [40] FAST AND SIMULTANEOUS DETERMINATION OF SULFAMETHOXAZOLE AND TRIMETHOPRIM USING BATCH INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION AND BORON-DOPED DIAMOND ELECTRODE
    Pereira, Polyana Fernandes
    da Silva, Weberson Pereira
    Abarza Munoz, Rodrigo Alejandro
    Richter, Eduardo Mathias
    QUIMICA NOVA, 2015, 38 (05): : 663 - 668