On the Limit of Detection in Infrared Spectroscopic Imaging

被引:8
|
作者
Lux, Laurin [1 ]
Phal, Yamuna [1 ,2 ]
Hsieh, Pei-Hsuan [1 ,3 ]
Bhargava, Rohit [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, 405 N Mathews Ave, Urbana, IL 61801 USA
[2] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
[3] Univ Illinois, Dept Bioengn, Urbana, IL 61801 USA
[4] Univ Illinois, Dept Mech Sci & Engn Chem & Biomol Engn & Chem, Urbana, IL 61801 USA
[5] Univ Illinois, Canc Ctr Illinois, Urbana, IL 61801 USA
基金
美国国家卫生研究院;
关键词
Limit of detection; LOD; chemical imaging; Fourier transform-infrared spectroscopy; FT-IR; binary hypothesis testing; discrete frequency infrared; noise; DIGITAL HISTOPATHOLOGY; SYNCHROTRON-RADIATION; MICROSPECTROSCOPY; DEFINITION; ARRAY;
D O I
10.1177/00037028211050961
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Infrared (IR) spectroscopic imaging instruments' performance can be characterized and optimized by an analysis of their limit of detection (LOD). Here we report a systematic analysis of the LOD for Fourier transform IR (FT-IR) and discrete frequency IR (DFIR) imaging spectrometers. In addition to traditional measurements of sample and blank data, we propose a decision theory perspective to pose the determination of LOD as a binary classification problem under different assumptions of noise uniformity and correlation. We also examine three spectral analysis approaches, namely, absorbance at a single frequency, average of absorbance over selected frequencies and total spectral distance - to suit instruments that acquire discrete or contiguous spectral bandwidths. The analysis is validated by refining the fabrication of a bovine serum albumin protein microarray to provide eight uniform spots from similar to 2.8 nL of solution for each concentration over a wide range (0.05-10 mg/mL). Using scanning parameters that are typical for each instrument, we estimate a LOD of 0.16 mg/mL and 0.12 mg/mL for widefield and line scanning FT-IR imaging systems, respectively, using the spectral distance approach, and 0.22 mg/mL and 0.15 mg/mL using an optimal set of discrete frequencies. As expected, averaging and the use of post-processing techniques such as minimum noise fraction transformation results in LODs as low as similar to 0.075 mg/mL that correspond to a spotted protein mass of similar to 112 fg/pixel. We emphasize that these measurements were conducted at typical imaging parameters for each instrument and can be improved using the usual trading rules of IR spectroscopy. This systematic analysis and methodology for determining the LOD can allow for quantitative measures of confidence in imaging an analyte's concentration and a basis for further improving IR imaging technology.
引用
收藏
页码:105 / 117
页数:13
相关论文
共 50 条
  • [21] Infrared spectroscopic imaging: a label free approach for the detection of amyloidosis in human tissue biopsies
    Martinez-Marin, David
    Sreedhar, Hari
    Walsh, Michael J.
    Picken, Maria M.
    AMYLOID-JOURNAL OF PROTEIN FOLDING DISORDERS, 2017, 24 : 163 - 164
  • [22] The limit of detection for explosives in spectroscopic differential reflectometry
    Dubroca, Thierry
    Vishwanathan, Karthik
    Hummel, Rolf. E.
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XII, 2011, 8018
  • [23] Infrared Imaging and Spectroscopy Beyond the Diffraction Limit
    Centrone, Andrea
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 8, 2015, 8 : 101 - 126
  • [24] Next-Generation Infrared Spectroscopic Imaging
    不详
    SPECTROSCOPY, 2015, 30 (01) : 32 - 35
  • [25] Investigation of the Limit of Detection of an Infrared Passive Remote Sensing and Scanning Imaging System for Pollution Gas
    Jiao Yang
    Xu Liang
    Gao Min-guang
    Jin Ling
    Tong Jing-jing
    Li Sheng
    Wei Xiu-li
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (10) : 2617 - 2620
  • [26] Multicolor Discrete Frequency Infrared Spectroscopic Imaging
    Yeh, Kevin
    Lee, Dongkwan
    Bhargava, Rohit
    ANALYTICAL CHEMISTRY, 2019, 91 (03) : 2177 - 2185
  • [27] Trends in Fourier transform infrared spectroscopic imaging
    Gerald Steiner
    Edmund Koch
    Analytical and Bioanalytical Chemistry, 2009, 394 : 671 - 678
  • [28] High-Definition Infrared Spectroscopic Imaging
    Reddy, Rohith K.
    Walsh, Michael J.
    Schulmerich, Matthew V.
    Carney, P. Scott
    Bhargava, Rohit
    APPLIED SPECTROSCOPY, 2013, 67 (01) : 93 - 105
  • [29] Infrared Emission Spectroscopic Imaging of a Combustion Flame
    Morita, Shigeaki
    Yatsuhashi, Ai
    Kitagawa, Kuniyuki
    BUNSEKI KAGAKU, 2012, 61 (04) : 275 - 279
  • [30] Infrared spectroscopy and spectroscopic imaging in forensic science
    Ewing, Andrew V.
    Kazarian, Sergei G.
    ANALYST, 2017, 142 (02) : 257 - 272