On the Limit of Detection in Infrared Spectroscopic Imaging

被引:8
|
作者
Lux, Laurin [1 ]
Phal, Yamuna [1 ,2 ]
Hsieh, Pei-Hsuan [1 ,3 ]
Bhargava, Rohit [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, 405 N Mathews Ave, Urbana, IL 61801 USA
[2] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
[3] Univ Illinois, Dept Bioengn, Urbana, IL 61801 USA
[4] Univ Illinois, Dept Mech Sci & Engn Chem & Biomol Engn & Chem, Urbana, IL 61801 USA
[5] Univ Illinois, Canc Ctr Illinois, Urbana, IL 61801 USA
基金
美国国家卫生研究院;
关键词
Limit of detection; LOD; chemical imaging; Fourier transform-infrared spectroscopy; FT-IR; binary hypothesis testing; discrete frequency infrared; noise; DIGITAL HISTOPATHOLOGY; SYNCHROTRON-RADIATION; MICROSPECTROSCOPY; DEFINITION; ARRAY;
D O I
10.1177/00037028211050961
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Infrared (IR) spectroscopic imaging instruments' performance can be characterized and optimized by an analysis of their limit of detection (LOD). Here we report a systematic analysis of the LOD for Fourier transform IR (FT-IR) and discrete frequency IR (DFIR) imaging spectrometers. In addition to traditional measurements of sample and blank data, we propose a decision theory perspective to pose the determination of LOD as a binary classification problem under different assumptions of noise uniformity and correlation. We also examine three spectral analysis approaches, namely, absorbance at a single frequency, average of absorbance over selected frequencies and total spectral distance - to suit instruments that acquire discrete or contiguous spectral bandwidths. The analysis is validated by refining the fabrication of a bovine serum albumin protein microarray to provide eight uniform spots from similar to 2.8 nL of solution for each concentration over a wide range (0.05-10 mg/mL). Using scanning parameters that are typical for each instrument, we estimate a LOD of 0.16 mg/mL and 0.12 mg/mL for widefield and line scanning FT-IR imaging systems, respectively, using the spectral distance approach, and 0.22 mg/mL and 0.15 mg/mL using an optimal set of discrete frequencies. As expected, averaging and the use of post-processing techniques such as minimum noise fraction transformation results in LODs as low as similar to 0.075 mg/mL that correspond to a spotted protein mass of similar to 112 fg/pixel. We emphasize that these measurements were conducted at typical imaging parameters for each instrument and can be improved using the usual trading rules of IR spectroscopy. This systematic analysis and methodology for determining the LOD can allow for quantitative measures of confidence in imaging an analyte's concentration and a basis for further improving IR imaging technology.
引用
收藏
页码:105 / 117
页数:13
相关论文
共 50 条
  • [1] Infrared spectroscopic imaging for noninvasive detection of latent fingerprints
    Crane, Nicole J.
    Bartick, Edward G.
    Perlman, Rebecca Schwartz
    Huffman, Scott
    JOURNAL OF FORENSIC SCIENCES, 2007, 52 (01) : 48 - 53
  • [2] Detection and Avoidance of Atmospheric Aviation Hazards Using Infrared Spectroscopic Imaging
    Prata, Fred
    REMOTE SENSING, 2020, 12 (14)
  • [3] Infrared spectroscopic imaging of skin
    Moore, DJ
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2004, 50 (03) : P32 - P32
  • [4] Trends in Infrared Spectroscopic Imaging
    不详
    SPECTROSCOPY, 2013, 28 (11) : 42 - +
  • [5] Trends in Infrared Spectroscopic Imaging
    不详
    SPECTROSCOPY, 2014, : 33 - 34
  • [6] Integrated recognition and quantitative detection of starch in surimi by infrared spectroscopy and spectroscopic imaging
    Hou, Shi-Wei
    Wei, Wei
    Wang, Yang
    Gan, Jian-Hong
    Lu, Ying
    Tao, Ning-Ping
    Wang, Xi-Chang
    Liu, Yuan
    Xu, Chang-Hua
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 215 : 1 - 8
  • [7] Spectroscopic detection of bladder cancer using near-infrared imaging techniques
    Demos, SG
    Gandour-Edwards, R
    Ramsamooj, R
    White, RD
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (04) : 767 - 771
  • [8] Detection of amyloidosis in human tissues using mid-infrared spectroscopic imaging
    Marin, David Martinez
    Sreedhar, Hari
    Walsh, Michael J.
    Picken, Maria M.
    AMYLOID-JOURNAL OF PROTEIN FOLDING DISORDERS, 2019, 26 : 93 - 94
  • [9] Resolution Limit in Infrared Chemical Imaging
    Phal, Yamuna
    Pfister, Luke
    Carney, P. Scott
    Bhargava, Rohit
    JOURNAL OF PHYSICAL CHEMISTRY C, 2022, 126 (23): : 9777 - 9783
  • [10] INFRARED AND RAMAN-SPECTROSCOPIC IMAGING
    TREADO, PJ
    MORRIS, MD
    APPLIED SPECTROSCOPY REVIEWS, 1994, 29 (01) : 1 - 38