THE APPLICATION OF WIND TUNNEL STUDY AND VIBRATION CONTROL IN BUILDING DESIGN

被引:0
|
作者
Ng, C. L. [1 ]
Wong, K. C. [1 ]
Lee, David C. S. [1 ]
Lim, Brian
机构
[1] AECOM Asia Co Ltd, Hong Kong, Hong Kong, Peoples R China
关键词
application; building; control; design; seismic; serviceability; vibration; wind; MODE SHAPE CORRECTIONS;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Design of building structures has been increasingly challenging because height, appearance and function of the buildings are being pushed to achieve a higher limit to demonstrate their unique identity among the others. Reviewing past experience in building design, it has been, however, noted that conventional design method sometimes has limitation in satisfying all kinds of serviceability performances of building structures but increase of building stiffness by enlargement of structural members seems to be the only solution. This paper introduces the research studies and application of control technology blended in some building projects in the aspects of wind engineering and vibration control. An urban redevelopment project in Hong Kong will be one of the example projects discussed. A methodology, namely linear-mode-shape (LMS) method, in wind analysis to the conventional wind tunnel study has been conducted in this project to provide reasonable estimation towards wind-induced responses of building. The application of tuned liquid damper (TLD) to improve building performance in terms of occupant comfort is also highlight of this project being discussed. Other vibration issues related to seismic events in will be another focus of this paper. Control devices of viscous damper and high hardness visco-elastic damper for enhancement of seismic performance of building structures are the examples introduced.
引用
收藏
页码:785 / 793
页数:9
相关论文
共 50 条
  • [21] Design of an experimental wind tunnel system for control applications
    Bayrak, Alper
    INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING EDUCATION, 2019, 56 (03) : 265 - 281
  • [22] Wind-tunnel tests of a bridge model with active vibration control
    2000, Int. Assoc. for Bridge and Structural Eng. Eth-Honggerberg (10):
  • [23] WIND-TUNNEL INVESTIGATION OF ACTIVE VIBRATION CONTROL OF TALL BUILDINGS
    FACIONI, RJ
    KWOK, KCS
    SAMALI, B
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1995, 54 : 397 - 412
  • [24] Multidimensional Vibration Suppression Method with Piezoelectric Control for Wind Tunnel Models
    Zhou, Mengde
    Liu, Wei
    Tang, Linlin
    Yao, Zhuang
    Wen, Zhengquan
    Liang, Bing
    Jia, Zhenyuan
    SENSORS, 2019, 19 (18)
  • [25] Design of Tuned Mass Damper Fluid Inerter for Wind-Induced Vibration Control of a Tall Building
    Sarkar, Saptarshi
    Fitzgerald, Breiffni
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (03)
  • [26] Active Vibration Control of the Sting Used in Wind Tunnel: Comparison of Three Control Algorithms
    Shen, Xing
    Dai, Yuke
    Chen, Mingxuan
    Zhang, Lei
    Yu, Li
    SHOCK AND VIBRATION, 2018, 2018
  • [27] Performance-based study on wind-vibration control of a high-rise building
    Zhou, Yun
    Wang, Da-Yang
    Li, Qing-Xiang
    Zhendong yu Chongji/Journal of Vibration and Shock, 2011, 30 (11): : 203 - 208
  • [28] Vibration analysis of wind tunnel support
    张旭
    张家泰
    董国庆
    张国友
    刘德富
    Journal of Harbin Institute of Technology(New series), 2004, (05) : 510 - 512
  • [29] Wind tunnel study on wind-induced vibration of middle pylon of Taizhou Bridge
    Ma Rujin1
    2.Norma Civiltech Co. Ltd.
    Engineering Sciences, 2012, 10 (03) : 77 - 80
  • [30] AN APPLICATION OF A COMPUTER TO WIND-TUNNEL DESIGN .2.
    HOLLINGDALE, SH
    BARRITT, MM
    COMPUTER JOURNAL, 1958, 1 (02): : 64 - 68