Post-tensioned timber structures: New perspectives

被引:6
|
作者
D'Aveni, Antonino [1 ]
D'Agata, Giuseppe [1 ]
机构
[1] Univ Catania, Dept Civil Engn & Architecture, Via Santa Sofia 64, I-95123 Catania, Italy
关键词
Glued laminated timber; Post-tensioning; Footbridge; Carbon fiber composite cable; WOOD MEMBERS; REINFORCEMENT;
D O I
10.1016/j.conbuildmat.2017.07.031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The structural behaviour of both glued laminated timber (GL) and laminated veneer lumber (LVL) is well described by the strength effectiveness ratio f/rho (resistance over unit weight) and the deformation effectiveness ratio E/rho (elastic modulus over unit weight). They are comparable to those provided by steel, together with the buckling effectiveness ratio E-0.5/rho which is higher than that provided by other structural materials. Current GL and LVL technologies, which give their best in covering wide spans, have probably reached their maximum capabilities and new ideas are growing up in order to improve this field of application. In the present paper, a new technology, which uses post-tensioning of timber beams, based on an Italian patent, is described. The structural behaviour, here analysed, shows a considerable improvement respect to the traditional technology, in terms of both strength and deformation. In particular, after the theoretical considerations that lie at the base of the idea, a case study is presented in which the behaviour of a post tensioned GL main girder of a footbridge is compared with a traditional timber and steel ones. The prestress is applied by means of a set of tendons made of carbon fiber composite cable (CFCC). (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:216 / 224
页数:9
相关论文
共 50 条
  • [21] Fragility functions for low-damage post-tensioned timber frames
    Matteoni, Michele
    Ciurlanti, Jonathan
    Bianchi, Simona
    Pampanin, Stefano
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2024, : 4741 - 4762
  • [22] FRP tendon anchorage in post-tensioned concrete structures
    Schmidt, J. W.
    Taljsten, B.
    Bennitz, A.
    Pedersen, H.
    [J]. CONCRETE REPAIR, REHABILITATION AND RETROFITTING II, 2009, : 419 - 420
  • [23] Post-tensioned ceramic structures: design, analysis and prototyping
    Martin Bechthold
    Zach Seibold
    Saurabh Mhatre
    [J]. Architecture, Structures and Construction, 2022, 2 (1): : 165 - 182
  • [24] Dynamic response of post-tensioned rocking structures with inerters
    Thiers-Moggia, R.
    Malaga-Chuquitaype, C.
    [J]. INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2020, 187
  • [25] Post-tensioned rocking dissipative timber wall systems: Numerical prediction
    Tomei, Valentina
    Zucconi, Maria
    Ferracuti, Barbara
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 66
  • [26] Design Approach to Predict Post-Tensioning Losses in Post-Tensioned Timber Frames
    Granello, Gabriele
    Leyder, Claude
    Palermo, Alessandro
    Frangi, Andrea
    Pampanin, Stefano
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (08)
  • [27] POST-TENSIONED TRANSPORTATION
    GARBER, G
    [J]. CIVIL ENGINEERING, 1989, 59 (10): : 67 - 69
  • [28] Numerical modelling and analysis of post-tensioned timber beam-column joint
    Rahmzadeh, Ahmad
    Iqbal, Asif
    [J]. ENGINEERING STRUCTURES, 2021, 245
  • [29] Experimental and analytical analysis of a post-tensioned timber connection under gravity loads
    Wanninger, F.
    Frangi, A.
    [J]. ENGINEERING STRUCTURES, 2014, 70 : 117 - 129
  • [30] Determination of the seismic performance factors for post-tensioned rocking timber wall systems
    Sarti, Francesco
    Palermo, Alessandro
    Pampanin, Stefano
    Berman, Jeffrey