Capillary extrusion viscometer for the viscosity measurement of fish protein paste

被引:0
|
作者
Kim, Byung Y. [1 ]
Park, Jae W. [2 ,3 ]
机构
[1] Kyung Hee Univ, Dept Food Sci, Yongin, South Korea
[2] Oregon State Univ, Dept Food Sci & Technol, Astoria, OR 97103 USA
[3] Oregon State Univ, Seafood Lab, Astoria, OR 97103 USA
关键词
D O I
10.1111/j.1745-4557.2007.00162.x
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
To overcome various limitations of conventional viscometers in measuring salted or unsalted surimi paste, a capillary extrusion viscometer was developed. The viscosity of surimi paste was measured as a function of moisture content (MC) (75-80%), salt content (2-4%) and liquid egg white (LEW) content (2-4%). As moisture, salt and LEW contents increased, viscosity gradually decreased. The viscosity values, as affected by MCs, showed a highly negative relationship with fracture properties of surimi gel, especially shear stress from the torsion test, indicating that MC is linearly correlated to the strength of gels at fracture. This easy and quick viscosity measurement can effectively facilitate the production control of comminuted muscle foods, including surimi paste.
引用
收藏
页码:536 / 548
页数:13
相关论文
共 50 条
  • [31] A MODIFIED UBBELOHDE VISCOMETER FOR MEASUREMENT OF VISCOSITY OF POLYMER SOLUTIONS
    HUGHES, J
    RHODEN, F
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (12): : 1134 - &
  • [32] AN ULTRASONIC VISCOMETER FOR THE MEASUREMENT OF DYNAMIC SHEAR VISCOSITY OF LIQUIDS
    BINDAL, VN
    CHANDRA, M
    SOM, JN
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1983, 21 (03) : 176 - 179
  • [33] VISCOSITY MEASUREMENT - THE KINETIC ENERGY CORRECTION AND A NEW VISCOMETER
    CANNON, MR
    MANNING, RE
    BELL, JD
    ANALYTICAL CHEMISTRY, 1960, 32 (03) : 355 - 358
  • [34] MEASUREMENT OF VISCOSITY OF BIOLOGIC FLUIDS BYCONE PLATE VISCOMETER
    WELLS, RE
    MERRILL, EW
    DENTON, R
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1961, 57 (04): : 646 - &
  • [35] EFFECT OF SHEAR TEMPERATURE ON VISCOSITY IN A ROTATIONAL VISCOMETER MEASUREMENT
    WELTMANN, RN
    KUHNS, PW
    JOURNAL OF COLLOID SCIENCE, 1952, 7 (03): : 218 - 226
  • [36] Experimental study on factors affecting the end effect in gas viscosity measurement using capillary-tube viscometer
    Fang, Xin
    Yue, Xiang'an
    Fu, Joseph Y.
    An, Weiqing
    Zou, Jirui
    Feng, Xuegang
    Tian, Wenhao
    An, Weijie
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (07):
  • [37] TIME DEPENDENCE OF VISCOSITY IN CAPILLARY EXTRUSION OF POLYETHYLENE
    RUDIN, A
    SCHREIBER, HP
    JOURNAL OF POLYMER SCIENCE, 1960, 44 (143): : 261 - 264
  • [38] Blood viscosity measurements using a pressure-scanning capillary viscometer
    Sehyun Shin
    Do-Young Keum
    Yun Hee Ku
    KSME International Journal, 2002, 16 : 1719 - 1724
  • [39] Capillary rheometry for studying slip flow in paste extrusion
    Graczyk, J
    Buggisch, H
    APPLIED MECHANICS AND ENGINEERING, VOL 4, SPECIAL ISSUE: "ICER '99", 1999: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON ENGINEERING RHEOLOGY ICER '99, 1999, : 45 - 50
  • [40] Reducing measurement uncertainty of a high pressure capillary viscometer
    Senkung der Messunsicherheit eines Hochdruck-Kapillarviskosimeters
    Boese, Norbert, 1995, Vincentz Verlag, Hannover, Germany (05):