Out-of-plane performance of a brick veneer steel-framed house subjected to seismic loads

被引:11
|
作者
Paton-Cole, Vidal P. [1 ]
Gad, Emad F. [2 ]
Clifton, Charles [3 ]
Lam, Nelson T. K. [1 ]
Davies, Carl
Hicks, Stephen
机构
[1] Univ Melbourne, Dept Infrastruct Engn, Parkville, Vic 3010, Australia
[2] Swinburne Univ Technol, Hawthorn, Vic 3122, Australia
[3] Univ Auckland, Dept Civil & Environm Engn, Auckland 1, New Zealand
关键词
Steel-framed; Brick veneer house; Out-of-plane; Seismic performance; Brick ties; Shaking table;
D O I
10.1016/j.conbuildmat.2011.10.033
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper summarises results of an experimental shaking table test program conducted on a single room steel-framed brick veneer house. The Test House was constructed of full scale components and represents current building practices in New Zealand. The primary objective of the test program was to assess the performance of the brick veneer walls when subjected to out-of-plane earthquake loading, having been previously subjected to in-plane loading which has the potential to weaken the veneer/tie/stud system for subsequent out-of-plane loading. The veneer walls of the Test House incorporated typical geometric features in different directions. The Test House was subjected to varying levels of the El-Centro (ElC) earthquake ranging from moderate Serviceability Limit State (SLS) ground motion to excitation well beyond the design Maximum Considered Earthquake (MCE) for New Zealand. These levels of excitation were selected in order to ascertain the response for specific limit states and compare against minimum performance requirements specified in the New Zealand Earthquake Standard, NZS 1170.5 (2004). Results presented are based on comprehensive measurements including acceleration, drift and differential movements between the structural steel frame and veneer. The Test House performed very well, with no brick loss up to 2.6 times ElC earthquake which is well in excess of all performance requirements. The results from the Test House under the onerous testing program reveal that such form of construction would be expected to exhibit good performance under both serviceability and ultimate conditions in New Zealand. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:779 / 790
页数:12
相关论文
共 50 条
  • [21] Nonlinear Dynamic Behavior of Unreinforced Masonry Walls Subjected to Out-of-Plane Loads
    Hamed, E.
    Rabinovitch, O.
    JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (11) : 1743 - 1753
  • [22] Flexural performance of composite walls under out-of-plane loads
    Sabouri-Ghomi, Saeid
    Nasri, Arman
    Jahani, Younes
    Bhowmick, Anjan K.
    STEEL AND COMPOSITE STRUCTURES, 2020, 34 (04): : 525 - 545
  • [23] THE INFLUENCE OF MORTAR HEAD JOINTS ON THE IN-PLANE AND OUT-OF-PLANE SEISMIC STRENGTH OF BRICK MASONRY WALLS
    Maheri, M. R.
    Najafgholipour, M. A.
    Rajabi, A. R.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2011, 35 (C1) : 63 - 79
  • [24] Out-of-plane seismic behavior and CFRP retrofitting of RC frames infilled with brick walls
    Chen, Wei-Wen
    Yeh, Yeong-Kae
    Hwang, Shyh-Jiann
    Lu, Ching-Hsien
    Chen, Cheng-Cheng
    ENGINEERING STRUCTURES, 2012, 34 : 213 - 224
  • [25] Seismic behaviour of Taiwanese timber complex brackets subjected to out-of-plane loading
    Yeo, Sok-Yee
    Chung, Yu-Lin
    Huang, Yu-Chih
    Yeh, Yu-Hsiang
    Hsu, Min-Fu
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-ENGINEERING HISTORY AND HERITAGE, 2021, 174 (01) : 15 - 31
  • [26] Evaluation of out-of-plane stability of unreinforced masonry walls subjected to seismic excitation
    Griffith, MC
    Magenes, G
    Melis, G
    Picchi, L
    JOURNAL OF EARTHQUAKE ENGINEERING, 2003, 7 : 141 - 169
  • [27] REQUIRED OUT-OF-PLANE RIGIDITIES OF STEEL ARCH BRIDGES WITH TWO MAIN RIBS SUBJECTED TO VERTICAL AND LATERAL LOADS.
    Kuranishi, Shigeru
    Yabuki, Tetsuya
    Technology Reports of the Tohoku University, 1981, 46 (01): : 47 - 72
  • [28] Analytical Model for the Seismic Performance of Cold-Formed Steel-Framed Gypsum Partition Walls
    Rahmanishamsi, E.
    Soroushian, S.
    Maragakis, E. M.
    Structures Congress 2015, 2015, : 1707 - 1718
  • [29] Confined masonry walls subjected to combined axial loads and out-of-plane uniform pressures
    Varela-Rivera, Jorge
    Polanco-May, Manuel
    Fernandez-Baqueiro, Luis
    Moreno, Eric I.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2012, 39 (04) : 439 - 447
  • [30] Numerical Study on the In-Plane and Out-of-Plane Resistance of Brick Masonry Infill Panels in Steel Frames
    Bahreini, Vahid
    Mahdi, Tariq
    Najafizadeh, MohammadMahdi
    SHOCK AND VIBRATION, 2017, 2017