Registration Accuracy of CT/MRI Fusion for Localisation of Deep Brain Stimulation Electrode Position: An Imaging Study and Systematic Review

被引:51
|
作者
Geevarghese, Ruben [1 ,2 ]
Tuura, Ruth O'Gorman [6 ]
Lumsden, Daniel E. [4 ]
Samuel, Michael [3 ]
Ashkan, Keyoumars [2 ,5 ]
机构
[1] Kings Coll Hosp NHS Fdn Trust, Kings Hlth Partners, Dept Neurosurg, Charing Cross Hosp, London, England
[2] Kings Coll Hosp NHS Fdn Trust, Kings Hlth Partners, Dept Neurosurg, London, England
[3] Kings Coll Hosp NHS Fdn Trust, Kings Hlth Partners, Dept Neurol, London, England
[4] Guys & St Thomas NHS Fdn Trust, Evelina Childrens Hosp, Complex Motor Disorders Serv, London, England
[5] Inst Psychiat, Clin Neurosci, London, England
[6] Univ Childrens Hosp, Dept MR Res, Zurich, Switzerland
关键词
Accuracy; CT; Deep brain stimulation; Electrode; Image registration; MRI; Review; PARKINSONS-DISEASE; MRI; CT;
D O I
10.1159/000446609
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Postoperative imaging is essential for verifying electrode location in patients undergoing deep brain stimulation (DBS). MRI offers better visualisation of brain targets, but concerns about adverse events have limited its use. Preoperative stereotactic MRI fused with a postoperative stereotactic CT, demonstrating the electrode position, is now widely used. Objectives: The aims of this study were to: (1) evaluate the accuracy of image registration using Neuroinspire, and (2) undertake a systematic review of the literature on CT/MRI fusion techniques to ascertain the accuracy of other software packages. Methods: Twenty patients who underwent bilateral subthalamic nucleus DBS for Parkinson's disease were selected. The postoperative CT was registered and fused with the preoperative MRI using Neuroinspire. The position of each electrode tip was determined in stereotactic coordinates both in the (unfused) postoperative CT and the fused CT/MRI. The difference in tip position was used to evaluate the registration accuracy. Results: The mean error +/- SD of CT/MRI fusion using Neuroinspire was 0.25 +/- 0.15, 0.33 +/- 0.26 and 0.46 +/- 0.55 mm in lateral, anteroposterior and vertical axes. A systematic review suggested that CT/MRI registration with Neuroinspire is more accurate than that achieved with other tested CT/MRI fusion algorithms. Conclusion: CT/MRI fusion for localisation of electrode placement offers an accurate, reliable and safe modality for assessing electrode location. (C) 2016 S. Karger AG, Basel
引用
收藏
页码:159 / 163
页数:5
相关论文
共 50 条
  • [41] Neurohistopathological Findings at the Electrode-Tissue Interface in Long-Term Deep Brain Stimulation: Systematic Literature Review, Case Report, and Assessment of Stimulation Threshold Safety COMMENTS
    Arle, Jeff
    Machado, Andre
    [J]. NEUROMODULATION, 2014, 17 (05): : 418 - 418
  • [42] Review of the targeting accuracy of frameless and frame-based robot-assisted deep brain stimulation electrode implantation in pediatric patients using the Neurolocate module
    David, Raenette
    Scala, Maria Rosaria
    Ellenbogen, Jonathan
    [J]. JOURNAL OF NEUROSURGERY-PEDIATRICS, 2024, 33 (03) : 207 - 213
  • [43] Ultra-high magnetic resonance imaging (MRI): a potential examination for deep brain stimulation devices and the limitation study concerning MRI-related heating injury
    Chen, Ying-Chuan
    Li, Jun-Ju
    Zhu, Guan-Yu
    Shi, Lin
    Yang, An-Chao
    Jiang, Yin
    Zhang, Xin
    Zhang, Jian-Guo
    [J]. NEUROLOGICAL SCIENCES, 2017, 38 (03) : 485 - 488
  • [44] Ultra-high magnetic resonance imaging (MRI): a potential examination for deep brain stimulation devices and the limitation study concerning MRI-related heating injury
    Ying-Chuan Chen
    Jun-Ju Li
    Guan-Yu Zhu
    Lin Shi
    An-Chao Yang
    Yin Jiang
    Xin Zhang
    Jian-Guo Zhang
    [J]. Neurological Sciences, 2017, 38 : 485 - 488
  • [45] Comparison of Glucagon-Like-Peptide-1 (GLP-1) Receptor PET/CT, SPECT/CT and 3T MRI for the Localisation of Insulinomas: Evaluation of Accuracy in a Prospective Crossover Imaging Study
    Antwi, A.
    Heye, T.
    Fani, M.
    Nicolas, G.
    Merkle, E.
    Zech, C.
    Boll, D.
    Rottenburger, C.
    Kaul, F.
    Gloor, B.
    Christ, E.
    Wild, D.
    [J]. NEUROENDOCRINOLOGY, 2018, 106 : 167 - 167
  • [46] Comparison of clinical outcomes and accuracy of electrode placement between robot-assisted and conventional deep brain stimulation of the subthalamic nucleus: a single-center study
    Ribault, Shams
    Simon, Emile
    Berthiller, Julien
    Polo, Gustavo
    Nunes, Adelaide
    Brinzeu, Andrei
    Mertens, Patrick
    Danaila, Teodor
    Thobois, Stephane
    Laurencin, Chloe
    [J]. ACTA NEUROCHIRURGICA, 2021, 163 (05) : 1327 - 1333
  • [47] Comparison of clinical outcomes and accuracy of electrode placement between robot-assisted and conventional deep brain stimulation of the subthalamic nucleus: a single-center study
    Shams Ribault
    Emile Simon
    Julien Berthiller
    Gustavo Polo
    Adélaïde Nunes
    Andrei Brinzeu
    Patrick Mertens
    Teodor Danaila
    Stéphane Thobois
    Chloé Laurencin
    [J]. Acta Neurochirurgica, 2021, 163 : 1327 - 1333
  • [48] Novel imaging techniques to study postmortem human fetal anatomy: a systematic review on microfocus-CT and ultra-high-field MRI
    Y. Dawood
    G. J. Strijkers
    J. Limpens
    R. J. Oostra
    B. S. de Bakker
    [J]. European Radiology, 2020, 30 : 2280 - 2292
  • [49] Novel imaging techniques to study postmortem human fetal anatomy: a systematic review on microfocus-CT and ultra-high-field MRI
    Dawood, Y.
    Strijkers, G. J.
    Limpens, J.
    Oostra, R. J.
    de Bakker, B. S.
    [J]. EUROPEAN RADIOLOGY, 2020, 30 (04) : 2280 - 2292
  • [50] Comparison of Glucagon-like Peptide-1 (GLP-1) receptor PET/CT, SPECT/CT and 3T MRI for the localisation of occult Insulinomas: evaluation of diagnostic accuracy in a prospective crossover imaging study
    Antwi, K.
    Fani, M.
    Heye, T.
    Nicolas, G.
    Rottenburger, C.
    Kaul, F.
    Merkle, E.
    Zech, C.
    Boll, D.
    Vogt, D.
    Gloor, B.
    Christ, E.
    Wild, D.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S87 - S87