Inhibiting the effect of 90Sr-90Y ophthalmic applicators on rat corneal neovascularization induced by sutures

被引:0
|
作者
Zhou, Hong-Yan [1 ]
Wang, Shuang [1 ]
Zhang, Hong [1 ]
Wang, Ling [1 ]
Zhang, Wen-Song [2 ]
机构
[1] Jilin Univ, China Japan Union Hosp, Dept Ophthalmol, Changchun 130033, Jilin Province, Peoples R China
[2] Jilin Univ, Hosp 2, Dept Ophthalmol, Changchun 130033, Jilin Province, Peoples R China
关键词
radiation; cornea; neovascularization; ENDOTHELIAL PROGENITOR CELLS; RADIATION-THERAPY; ANGIOGENESIS; BRACHYTHERAPY; RADIOTHERAPY; TISSUE;
D O I
10.18240/ijo.2016.09.02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To investigate a practical technique used to inhibit corneal angiogenesis with a Sr-90-Y-90 ophthalmic applicator. METHODS: A Sr-90-Y-90 ophthalmic applicator was detected with a radioactive nuclide application treatment healthy protection standard. The applicator used was produced through medical dosimetry research; it had a concave applicator add measured the applicator temperature, serviceable humidity range, applicator appearance status, applicator radiation homogeneity, radioautography, and radiological safety of the original applicator surface. A vessel model was established using newborn rats, with sutures around the corneal limbus. Corneal neovascularization (CNV) were observed with a slit lamp. The new vessel length and response area were measured. RESULTS: Low-dose radiation can inhibit CNV after corneal sutures. The absorbed dose of the applicator (0.046 Gy/s) was safe for the treatment of it. The lengths of new vessels and the areas of new vessels were lower than the new born vessel rat group (P<0.01). CONCLUSION: The optimal radiation dose emitting from the applicator can be safe and potentially used in humans.
引用
收藏
页码:1251 / 1254
页数:4
相关论文
共 50 条
  • [41] Determination of 90Sr-90Y activity in urine samples by using Cherenkov counting
    Tsroya, S.
    German, U.
    Pelled, O.
    Katorza, E.
    Alfassi, Z. B.
    APPLIED RADIATION AND ISOTOPES, 2013, 73 : 12 - 16
  • [42] Results on Sr-90+Y-90 applicators dosimetry using extrapolation chambers
    Dias, SK
    Caldas, LV
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D227 - D229
  • [43] 90Sr-90Y放射性活度的绝对测量
    吕峰
    陈国安
    贺先运
    种培基
    原子能科学技术, 1984, (04) : 488 - 490
  • [44] 90Sr-90Y敷贴治疗跖疣62例临床观察
    靳情
    邹志勇
    蚌埠医学院学报, 2007, (05) : 599 - 600
  • [45] 90Sr-90Y敷贴治疗增生性瘢痕的疗效观察
    徐燕红
    杨吉生
    王强
    云南医药, 2007, (02) : 119 - 120
  • [46] MOS器件90Sr-90Y源电离辐射效应研究
    罗尹虹
    张正选
    吴国荣
    彭宏论
    微电子学, 2000, (01) : 32 - 35
  • [47] BIOLOGICAL BEHAVIOUR OF MOTHER AND DAUGHTER SUBSTANCES AFTER INCORPORATION OF 90SR-90Y IN RATS
    STEINBAC.KH
    ATOMPRAXIS, 1966, 12 (12): : 599 - &
  • [48] 90Sr-90Y敷贴治疗鸡眼23例临床疗效观察
    刘秦元
    刘惊涛
    林世修
    张维娥
    实用医技杂志, 2004, (17) : 2306 - 2306
  • [49] 90Sr-90Y放射性活度的绝对测量
    吕峰
    陈国安
    贺先运
    种培基
    中国核科技报告, 1986, (00)
  • [50] 90Sr-90Y敷贴治疗疤痕疙瘩60例分析
    林春燕,梁爱武,吴晓红
    福建医药杂志, 1996, (03) : 60 - 61