Modelling tri-cortical pedicle screw fixation in thoracic vertebrae under osteoporotic condition: A finite element analysis based on computed tomography

被引:13
|
作者
Zhang, Wencan [1 ]
Zhao, Junyong [2 ]
Li, Le [1 ]
Yu, Chenxiao [1 ]
Zhao, Yuefeng [2 ]
Si, Haipeng [1 ]
机构
[1] Shandong Univ, Qilu Hosp, Jinan 250012, Peoples R China
[2] Shandong Normal Univ, Coll Phys & Elect Sci, Jinan 250000, Peoples R China
基金
中国博士后科学基金;
关键词
Tri-cortical pedicle screw; Biomechanics; Finite element analysis; 3D medical image reconstruction; Computed tomography; SPINE; COMPLICATIONS; BIOMECHANICS; PLACEMENT; FRACTURE; SEGMENT;
D O I
10.1016/j.cmpb.2019.105035
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: The technique of tri-cortical pedicle screw (TCPS) has been used to improve the anchoring strength in the sacral vertebrae. However, no studies have reported their application in the thoracic vertebrae. Our research is aimed to assess the stability and strength of the TCPS in thoracic vertebrae under osteoporotic condition by three dimensional (3D) finite element method on the basis of medical image reconstruction using computed tomography (CT), and verifying its effectiveness in clinical application. Materials and methods: The 3D finite element models were constructed using Mimcs to transfer two dimensional CT images into 3D models by marching cubes algorithm of six-partition. Six physiological activities were simulated in 3D finite element models. Compared with the strength and stability of the uni-cortical pedicle screw (UCPS) and bi-cortical pedicle screw (BCPS), the effectiveness of TCPS was assessed. The stress distribution and maximum stress were measured to evaluate the strength. The maximum displacement and the range of motion were analysed to assessed the stability. Experimental results: Four geometrically accurate and nonlinear T7-T9 finite element models were constructed successfully by 3D finite element method based on the CT images. Three kinds of internal fixation methods in the osteoporotic thoracic vertebral body can improved the maximum stress, decrease the maximum displacement and range of motion in six physiological activities. The range of motion and maximum displacement of TCPS decreased more significantly than that of UCPS and BCPS. The maximum von Mises stress of TCPS was minimum and UCPS was maximum under the condition of extension, right lateral bending, left rotation and right rotation. Conclusions: Effectively, TCPS can provide better stability and strength than that of UCPS and BCPS techniques in the osteoporotic thoracic vertebrae. In practice, the technique of TCPS can be applied in the osteoporotic thoracic vertebral body to enhance the griping strength of the screws and reduce the risk of pedicle screw loosening. However, further cadaver experiments and more biomechanical analysis are necessary to confirmed our findings. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 15 条
  • [1] Impact of Screw Diameter and Length on Pedicle Screw Fixation Strength in Osteoporotic Vertebrae: A Finite Element Analysis
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Imabayashi, Hideaki
    ASIAN SPINE JOURNAL, 2021, 15 (05) : 566 - 574
  • [2] The benefits of cement augmentation of pedicle screw fixation are increased in Osteoporotic bone: A finite element analysis
    Wang W.
    Baran G.R.
    Garg H.
    Betz R.R.
    Moumene M.
    Cahill P.J.
    Spine Deformity, 2014, 2 (4) : 248 - 259
  • [3] Stent-Screw Assisted Internal Fixation of Osteoporotic Vertebrae: A Comparative Finite Element Analysis on SAIF Technique
    La Barbera, Luigi
    Cianfoni, Alessandro
    Ferrari, Andrea
    Distefano, Daniela
    Bonaldi, Giuseppe
    Villa, Tomaso
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2019, 7 (OCT):
  • [4] Thoracic vertebra fixation with a novel screw-plate system based on computed tomography imaging and finite element method
    Zhang, Wencan
    Zhao, Junyong
    Jiang, Xiujuan
    Li, Le
    Yu, Chenxiao
    Zhao, Yuefeng
    Si, Haipeng
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 187
  • [5] Biomechanical investigation of the hybrid modified cortical bone screw-pedicle screw fixation technique: Finite-element analysis
    Kahaer, Alafate
    Maimaiti, Xieraili
    Maitirouzi, Julaiti
    Wang, Shuiquan
    Shi, Wenjie
    Abuduwaili, Nueraihemaiti
    Zhou, Zhihao
    Liu, Dongshan
    Maimaiti, Abulikemu
    Rexiti, Paerhati
    FRONTIERS IN SURGERY, 2022, 9
  • [6] FINITE ELEMENT ANALYSIS OF L3-L4 VERTEBRAE AT VARIOUS BODY POSTURES UNDER OSTEOPOROTIC CONDITION
    Resmi, S. L.
    Mohan, Ananthu
    Firoz, N.
    Hashim, V
    Dileep, P. N.
    INTERNATIONAL CONFERENCE ON AEROSPACE AND MECHANICAL ENGINEERING, 2019, 1355
  • [7] A Finite Element Analysis Based Sensitivity Studies on Pull Out Strength of Pedicle Screw in Synthetic Osteoporotic Bone Models
    Varghese, Vicky
    Kumar, G. Saravana
    Venkatesh, K.
    2016 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2016, : 382 - 387
  • [8] Translaminar Screw Fixation in the Upper Thoracic Spine: Computed Tomography-Based Quantitative Laminar Analysis and Feasibility Study of Translaminar Virtual Screw Placement
    Qing-Feng Hu
    Rong-Ming Xu
    Hao Pan
    Hui Zhou
    Wei Lei
    Cell Biochemistry and Biophysics, 2015, 73 : 191 - 198
  • [9] Translaminar Screw Fixation in the Upper Thoracic Spine: Computed Tomography-Based Quantitative Laminar Analysis and Feasibility Study of Translaminar Virtual Screw Placement
    Hu, Qing-Feng
    Xu, Rong-Ming
    Pan, Hao
    Zhou, Hui
    Lei, Wei
    CELL BIOCHEMISTRY AND BIOPHYSICS, 2015, 73 (01) : 191 - 198
  • [10] Computed tomography-based reconstruction and finite element modelling of honeycomb sandwiches under low-velocity impacts
    Crupi, Vincenzo
    Epasto, Gabriella
    Guglielmino, Eugenio
    Mozafari, Hozhabr
    Najafian, Sarah
    JOURNAL OF SANDWICH STRUCTURES & MATERIALS, 2014, 16 (04) : 377 - 397