On-column concentration and separation of double-stranded DNA by gradient capillary electrophoresis

被引:23
|
作者
Kuo, IT [1 ]
Chiu, TC [1 ]
Chang, HT [1 ]
机构
[1] Natl Taiwan Univ, Dept Chem, Taipei 10764, Taiwan
关键词
DNA; gradient capillary electrophoresis; laser-induced fluorescence; polymer solutions;
D O I
10.1002/elps.200305603
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe the separation of dsDNA by capillary electrophoresis in the presence of electroosmotic flow (EOF) using poly(ethylene oxide) (PEO). Using 1.0% PEO, the separation of DNA fragments with sizes ranging from 51 bp to 23 kbp has been achieved in less than 12 min, which is better than conventional methods (in the absence of EOF) in terms of speed and resolution. In order to concentrate and separate the DNA sample, gradient changes in the concentrations of PEO and ethidium bromide (EtBr) have been conducted. Different concentrations of PEO solutions are injected to the polyethylene tubes by pressure, where they enter the capillary by EOF Because the large DNA fragments migrate faster towards the cathode end under counterflow conditions, the introduction sequence is from low to high concentrations of PEO solutions after sample injection. Using the gradient CE approach, the separations of the DNA sample injected at 30 cm height for times up to 120 s have been demonstrated. The linearity between injection time and peak height shows that the DNA fragments stacked during migration from the sample zone to PEO. We found that stacking efficiency is greater when the analysis was performed by simultaneously changing the PEO and EtBr concentration, compared to individual changes in PEO concentration.
引用
收藏
页码:3339 / 3347
页数:9
相关论文
共 50 条
  • [41] On-column electrochemical detection for microchip capillary electrophoresis
    Osbourn, DM
    Lunte, CE
    ANALYTICAL CHEMISTRY, 2003, 75 (11) : 2710 - 2714
  • [42] ON-COLUMN DOUBLE-BEAM LASER-ABSORPTION DETECTION FOR CAPILLARY ELECTROPHORESIS
    XUE, YJ
    YEUNG, ES
    ANALYTICAL CHEMISTRY, 1993, 65 (15) : 1988 - 1993
  • [43] ON-COLUMN CONDUCTIVITY DETECTOR FOR CAPILLARY ZONE ELECTROPHORESIS
    HUANG, XH
    PANG, TKJ
    GORDON, MJ
    ZARE, RN
    ANALYTICAL CHEMISTRY, 1987, 59 (23) : 2747 - 2749
  • [44] Analysis of double-stranded DNA fragments by capillary electrophoresis using entangle polymer solutions in uncoated fused silica capillary columns
    Lee, JJ
    Lee, KJ
    JOURNAL OF BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1998, 31 (04): : 384 - 390
  • [45] Force-Driven Separation of Short Double-Stranded DNA
    Ho, Dominik
    Zimmermann, Julia L.
    Dehmelt, Florian A.
    Steinbach, Uta
    Erdmann, Matthias
    Severin, Philip
    Falter, Katja
    Gaub, Hermann E.
    BIOPHYSICAL JOURNAL, 2009, 97 (12) : 3158 - 3167
  • [46] NEW CHROMATOGRAPHIC METHOD FOR SEPARATION OF SINGLE-STRANDED DNA, DOUBLE-STRANDED DNA AND RNA
    UDVARDY, A
    VENETIANER, P
    ACTA BIOCHIMICA AND BIOPHYSICA ACADEMIAE SCIENTARIUM HUNGARICA, 1971, 6 (01): : 27 - +
  • [47] Evaluation of different nucleic acid stains for sensitive double-stranded DNA analysis with capillary electrophoretic separation
    Yan, XM
    Hang, W
    Majidi, V
    Marrone, BL
    Yoshida, TM
    JOURNAL OF CHROMATOGRAPHY A, 2002, 943 (02) : 275 - 285
  • [48] Reduced viscosity polymer matrices for microchip electrophoresis of double-stranded DNA
    Xu, F
    Jabasini, M
    Liu, SQ
    Baba, Y
    ANALYST, 2003, 128 (06) : 589 - 592
  • [49] DETECTION OF MISMATCHED BASES IN DOUBLE-STRANDED DNA BY GEL-ELECTROPHORESIS
    GANGULY, A
    PROCKOP, DJ
    ELECTROPHORESIS, 1995, 16 (10) : 1830 - 1835
  • [50] Overstretching Double-Stranded RNA, Double-Stranded DNA, and RNA-DNA Duplexes
    Melkonyan, Lena
    Bercy, Mathilde
    Bizebard, Thierry
    Bockelmann, Ulrich
    BIOPHYSICAL JOURNAL, 2019, 117 (03) : 509 - 519