Sensorless Virtual Resistance Damping Method for Grid-Connected Three-Phase PWM Converter with LCL Filter

被引:0
|
作者
Koiwa, Kenta [1 ]
Rosyadi, Marwan [1 ]
Umemura, Atsusi [1 ]
Takahashi, Rion [1 ]
Tamura, Junji [1 ]
机构
[1] Kitami Inst Technol, Kitami, Hokkaido 090, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Three-phase PWM converter is commonly connected to utility grid through L or LCL filter to remove grid current harmonic components. LCL filter has many advantages compared with L filter. However, resonance at high frequency caused by the LCL filter may lead stability problem. Passive damping method (PD) or active damping method (AD) is used to solve this problem. PD brings the additional loss due to damping resistor. On the other hand, virtual resistance damping method of AD, in general, needs additional sensor. Therefore, this paper proposes sensorless virtual resistance damping method for grid-connected three-phase PWM converter with LCL filter.
引用
收藏
页码:1746 / 1749
页数:4
相关论文
共 50 条
  • [21] Simple and systematic LCL filter design for three-phase grid-connected power converters
    Ben Said-Romdhane, M.
    Naouar, M. W.
    Belkhodja, I. Slama
    Monmasson, E.
    [J]. MATHEMATICS AND COMPUTERS IN SIMULATION, 2016, 130 : 181 - 193
  • [22] A Virtual RC Active Damping Method in Weak Grid for Three-level Three-phase Grid-connected Inverters
    Yang Yong
    Fang Gang
    Lu Jinjun
    Jiang Feng
    Liu Tao
    [J]. 2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016, : 741 - 747
  • [23] LCL Filter Design for Grid Connected Three-Phase Inverter
    Dursun, Mustafa
    Dosoglu, M. Kenan
    [J]. 2018 2ND INTERNATIONAL SYMPOSIUM ON MULTIDISCIPLINARY STUDIES AND INNOVATIVE TECHNOLOGIES (ISMSIT), 2018, : 67 - 70
  • [24] A Full-Feedforward Scheme of Grid Voltages for a Three-Phase Grid-Connected Inverter With an LCL Filter
    Li, Weiwei
    Pan, Donghua
    Ruan, Xinbo
    Wang, Xuehua
    [J]. 2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 96 - 103
  • [25] Dc voltage sensorless control method for three-phase grid-connected inverters
    Wang, Z.
    Chang, L.
    Mao, M.
    [J]. IET POWER ELECTRONICS, 2010, 3 (04) : 552 - 558
  • [26] State Observer for Grid-Voltage Sensorless Control of a Grid-Connected Converter Equipped With an LCL Filter
    Kukkola, Jarno
    Hinkkanen, Marko
    [J]. 2014 16TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'14-ECCE EUROPE), 2014,
  • [27] State Observer for Grid-Voltage Sensorless Control of a Grid-Connected Converter Equipped With an LCL Filter
    Kukkola, Jarno
    Hinkkanen, Marko
    [J]. EPE JOURNAL, 2015, 25 (03) : 21 - 27
  • [28] Sensorless Active Damping Method for an LCL Filter in Grid-Connected Parallel Inverters for Battery Energy Storage Systems
    Sung, Won-Yong
    Ahn, Hyo Min
    Ahn, Jung-Hoon
    Lee, Byoung Kuk
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2018, 13 (01) : 280 - 286
  • [29] Interconnection and Damping Assignment Passivity-Based Current Control of Grid-Connected PWM Converter with LCL-Filter
    Boettcher, Matthias
    Dannehl, Joerg
    Fuchs, Friedrich W.
    [J]. PROCEEDINGS OF 14TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE-PEMC 2010), 2010,
  • [30] Design of three-phase LCL-filter for grid-connected PWM voltage source inverter using bacteria foraging optimization
    Bayoumi, Ehab H. E.
    [J]. Energy Systems, 2016, 0 : 199 - 229