Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior

被引:13
|
作者
Vatansever, Cuneyt [1 ]
Kutsal, Kutay [1 ]
机构
[1] Istanbul Tech Univ, Dept Civil Engn, TR-34469 Istanbul, Turkey
来源
STEEL AND COMPOSITE STRUCTURES | 2018年 / 28卷 / 06期
关键词
steel moment frames; steel beam-to-column connections; column-tree connection; beam splice; plastic hinge; protected zone; finite element analysis; plastic equivalent strain; rupture index; TREE MOMENT CONNECTIONS; SEISMIC PERFORMANCE EVALUATION; CYCLIC BEHAVIOR; BRACED FRAMES;
D O I
10.12989/scs.2018.28.6.767
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The purpose of this study is to investigate how a fully restrained bolted beam splice affects the connection behavior as a column-tree connection in steel special moment frames under cyclic loading when located within the plastic hinge zone. The impacts of this attachment in protected zone are observed by using nonlinear finite element analyses. This type of splice connection is designed as slip-critical connection and thereby, the possible effects of slippage of the bolts due to a possible loss of pretension in the bolts are also investigated. The 3D models with solid elements that have been developed includes three types of connections which are the connection having fully restrained beam splice located in the plastic hinge location, the connection having fully restrained beam splice located out of the plastic hinge and the connection without beam splice. All connection models satisfied the requirement for the special moment frame connections providing sufficient flexural resistance, determined at column face stated in AISC 341-16. In the connection model having fully restrained beam splice located in the plastic hinge, due to the pretension loss in the bolts, the friction force on the contact surfaces is exceeded, resulting in a relative slip. The reduction in the energy dissipation capacity of the connection is observed to be insignificant. The possibility of the crack occurrence around the bolt holes closest to the column face is found to be higher for the splice connection within the protected zone.
引用
收藏
页码:767 / 778
页数:12
相关论文
共 50 条
  • [21] Seismic Behavior of Steel Moment Frames with Mechanical Hinge Beam-to-Column Connections
    Peng, Han
    Ou, Jinping
    Schellenberg, Andreas
    Mckenna, Frank
    Mahin, Stephen
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2020, 20 (06)
  • [22] PLASTIC BEHAVIOR OF UNSTIFFENED SYMMETRICAL BEAM-TO-COLUMN FLANGE CONNECTIONS
    ELGHAZALY, HA
    SHERBOURNE, AN
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1985, 12 (04) : 821 - 837
  • [23] BEAM-TO-COLUMN WEB CONNECTION DETAILS
    RENTSCHLER, GP
    CHEN, WF
    DRISCOLL, GC
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1982, 108 (02): : 393 - 409
  • [24] BEAM-TO-COLUMN CONNECTION RESEARCH IN JAPAN
    KATO, B
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1982, 108 (02): : 343 - 360
  • [25] Study on the progressive collapse behavior of fully bolted RCS beam-to-column connections
    Tang, Hongyuan
    Deng, Xuezhi
    Jia, Yigang
    Xiong, Jingang
    Peng, Chunmei
    ENGINEERING STRUCTURES, 2019, 199
  • [26] Flexural behavior of clad rack beam-to-column bolted connections at high temperatures
    Liao, Hui
    Jiang, Shou-Chao
    Wang, Yuan-Zuo
    Zhu, Shaojun
    Zhao, Xianzhong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 197
  • [27] Seismic behavior of bolted beam-to-column connections for concrete filled steel tube
    Wu, LY
    Chung, LL
    Tsai, SF
    Shen, TJ
    Huang, GL
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (10) : 1387 - 1410
  • [28] Behaviour of RHS beam-to-column bolted steel connections
    dos Santos, Gabriel Barros
    Batista, Eduardo de Miranda
    Mascarenhas de Araujo, Afonso Henrique
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2016, 9 (04): : 296 - 304
  • [29] TESTS OF BOLTED BEAM-TO-COLUMN FLANGE MOMENT CONNECTIONS
    STANDIG, KF
    RENTSCHLER, GP
    CHEN, WF
    WELDING RESEARCH COUNCIL BULLETIN, 1976, (218): : 1 - 17
  • [30] Cyclic behavior of a new mechanical beam-to-column connection for steel structures
    Iyama, J.
    Fukushima, Y.
    Araki, K.
    Piao, S.
    Hirosawa, K.
    Sato, N.
    Ohata, E.
    STESSA 2012: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2012, : 179 - 185