Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior

被引:13
|
作者
Vatansever, Cuneyt [1 ]
Kutsal, Kutay [1 ]
机构
[1] Istanbul Tech Univ, Dept Civil Engn, TR-34469 Istanbul, Turkey
来源
STEEL AND COMPOSITE STRUCTURES | 2018年 / 28卷 / 06期
关键词
steel moment frames; steel beam-to-column connections; column-tree connection; beam splice; plastic hinge; protected zone; finite element analysis; plastic equivalent strain; rupture index; TREE MOMENT CONNECTIONS; SEISMIC PERFORMANCE EVALUATION; CYCLIC BEHAVIOR; BRACED FRAMES;
D O I
10.12989/scs.2018.28.6.767
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The purpose of this study is to investigate how a fully restrained bolted beam splice affects the connection behavior as a column-tree connection in steel special moment frames under cyclic loading when located within the plastic hinge zone. The impacts of this attachment in protected zone are observed by using nonlinear finite element analyses. This type of splice connection is designed as slip-critical connection and thereby, the possible effects of slippage of the bolts due to a possible loss of pretension in the bolts are also investigated. The 3D models with solid elements that have been developed includes three types of connections which are the connection having fully restrained beam splice located in the plastic hinge location, the connection having fully restrained beam splice located out of the plastic hinge and the connection without beam splice. All connection models satisfied the requirement for the special moment frame connections providing sufficient flexural resistance, determined at column face stated in AISC 341-16. In the connection model having fully restrained beam splice located in the plastic hinge, due to the pretension loss in the bolts, the friction force on the contact surfaces is exceeded, resulting in a relative slip. The reduction in the energy dissipation capacity of the connection is observed to be insignificant. The possibility of the crack occurrence around the bolt holes closest to the column face is found to be higher for the splice connection within the protected zone.
引用
收藏
页码:767 / 778
页数:12
相关论文
共 50 条
  • [1] Mechanical behavior of bolted beam-to-column connections with panel zone yielding
    Suita, K
    Inoue, K
    Kanoh, N
    STESSA 2003: BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2003, : 363 - 368
  • [2] Experimental study of beam-to-column connection with bolted joints
    Koyama, Y.
    Sato, A.
    Idota, H.
    Sato, Y.
    Yagi, S.
    Takaki, S.
    Kamada, M.
    STABILITY AND DUCTILITY OF STEEL STRUCTURES 2019, 2019, : 638 - 645
  • [3] Seismic behavior of precast concrete beam-to-column connection with double box bolted couplers
    Zhang, Hao
    Huang, Wei
    Li, Jiashen
    Quan, Wenli
    ENGINEERING STRUCTURES, 2025, 326
  • [4] Experimental study on beam-to-column clip angle bolted connection
    Natesan, Vijayakumar
    Madhavan, Mahendrakumar
    THIN-WALLED STRUCTURES, 2019, 141 : 540 - 553
  • [5] Cyclic behavior of bolted and welded beam-to-column joints
    Yang, Cheol Min
    Kim, Young Moon
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2007, 49 (05) : 635 - 649
  • [7] Numerical analysis of a prefabricated concrete beam-to-column connection with bolted end plates
    Zhang, Hao
    Huang, Wei
    Liu, Bolong
    Li, Shufeng
    Li, Qingning
    Mao, Lu
    STRUCTURES, 2024, 59
  • [8] A new form of high moment capacity bolted steel beam-to-column connection
    Yeung, KW
    STRUCTURES IN THE NEW MILLENNIUM, 1997, : 311 - 318
  • [9] ANALYSIS OF THE STAINLESS STEEL BEAM-TO-COLUMN CONNECTION PANEL ZONE
    Lin, Zihong
    Shi, Gang
    Fundamental Research in Structural Engineering: Retrospective and Prospective, Vols 1 and 2, 2016, : 481 - 484
  • [10] Comparative experimental studies on the web cleat bolted CFS beam-to-column connection
    Natesan, Vijayakumar
    Shanmugasundaram, Bharath
    Madhavan, Mahendrakumar
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 170