Nanostructured Cuprous-Oxide-Based Screen-Printed Electrode for Electrochemical Sensing of Picric Acid

被引:13
|
作者
James, Soorya [1 ]
Chishti, Benazir [1 ]
Ansari, Sajid Ali [2 ]
Alothman, Othman Y. [3 ,4 ]
Fouad, H. [5 ,6 ]
Ansari, Z. A. [1 ]
Ansari, S. G. [1 ]
机构
[1] Jamia Millia Islamia, Ctr Interdisciplinary Res Basic Sci, New Delhi 110025, India
[2] King Faisal Univ, Dept Phys, Coll Sci, Al Hasa 31982, Saudi Arabia
[3] King Saud Univ, Dept Chem Engn, Riyadh 11421, Saudi Arabia
[4] Saudi Elect Univ, Grad Studies, Riyadh 13316, Saudi Arabia
[5] King Saud Univ, Dept Appl Sci Med, Community Coll, Riyadh 11437, Saudi Arabia
[6] Helwan Univ, Dept Biomed Engn, Fac Engn, Helwan 11792, Egypt
关键词
Nanostructured metal oxides; picric acid; electrochemical sensor; Cu2O morphologies; REDUCED GRAPHENE OXIDE; SELECTIVE DETECTION; CHEMICAL SENSOR; BIOSENSORS; NANOPARTICLES; PHOTOCATHODES; NANOMATERIALS;
D O I
10.1007/s11664-018-6692-9
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The sensitive and selective electrochemical detection of picric acid (PA), a toxic, harmful environmental pollutant and an explosive, using different morphologies of cuprous oxide (Cu2O) is reported. The different Cu2O morphologies, synthesized by a hydrothermal method for 8h, 10h, and 12h, were characterized using various techniques to confirm their morphological, optical, compositional, and structural properties. Sensors, fabricated in the form of screen-printed electrodes using these different morphologies of Cu2O, were used to study the electrochemical sensing capabilities of the nanomaterials for PA (7.8 mu M to 10.0 mM). Cyclic voltammetry studies revealed a distinct change in the redox peak current as a function of PA concentration, which was further confirmed by electrochemical impedance spectroscopy studies, as the charge-transfer resistance increased with an increase in PA concentration. Scan rate studies showed that the electrochemical sensing of PA is a surface-controlled process, involving rapid electron transfer. Among the different morphologies, Cu2O synthesized for 8h showed a reproducible and reliable sensitivity of 130.4 mu A mM(-1)cm(-2) with a limit of detection of 39 mu M and good linearity over a wide range of PA concentrations. Interference studies with other phenolic compounds revealed the presence of distinct peaks corresponding to PA, indicating that the fabricated sensor shows specificity and selectivity for PA.
引用
收藏
页码:7505 / 7513
页数:9
相关论文
共 50 条
  • [1] Nanostructured Cuprous-Oxide-Based Screen-Printed Electrode for Electrochemical Sensing of Picric Acid
    Soorya James
    Benazir Chishti
    Sajid Ali Ansari
    Othman Y. Alothman
    H. Fouad
    Z. A. Ansari
    S. G. Ansari
    Journal of Electronic Materials, 2018, 47 : 7505 - 7513
  • [2] Study on electrochemical biosensor based on screen-printed electrode
    Zou, Quan
    Cheng, Gong
    Zhang, Yu
    MODERN PHYSICS LETTERS B, 2018, 32 (34-36):
  • [3] Chemically-Treated Screen-Printed Graphene Electrode for Electrochemical Sensing
    Huang, Yu-Ming
    Settu, Kalpana
    Tsai, Jang-Zern
    2020 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - TAIWAN (ICCE-TAIWAN), 2020,
  • [4] Glycated Hemoglobin Electrochemical Immunosensor Based on Screen-Printed Electrode
    Zhao, Yuliang
    Zhang, Hongyu
    Li, Yang
    Wang, Xiaoai
    Zhao, Liang
    Xu, Jianghong
    Zhan, Zhikun
    Zhang, Guanglie
    Li, Wen Jung
    Biosensors, 2022, 12 (10):
  • [5] Glycated Hemoglobin Electrochemical Immunosensor Based on Screen-Printed Electrode
    Zhao, Yuliang
    Zhang, Hongyu
    Li, Yang
    Wang, Xiaoai
    Zhao, Liang
    Xu, Jianghong
    Zhan, Zhikun
    Zhang, Guanglie
    Li, Wen Jung
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [6] Conductive disposable screen-printed graphene oxide-molybdenum disulfide electrode for electrochemical sensing applications
    Pasakon, Patiya
    Primpray, Vitsarut
    Thangphatthanarungruang, Jeerakit
    Kamsong, Wichayaporn
    Wisitsoraat, Anurat
    Laiwattanapaisal, Wanida
    Intasanta, Varol
    Karuwan, Chanpen
    ELECTROCHEMISTRY COMMUNICATIONS, 2024, 166
  • [7] Nanostructured Cerium-Oxide-Based Screen Printed Electrode for Electrochemical Detection of Melamine via Ascorbic Acid
    Mishra, Sapna
    Chishti, Benazir
    Fouad, H.
    Seo, H. K.
    Ansari, Z. A.
    SCIENCE OF ADVANCED MATERIALS, 2020, 12 (02) : 220 - 227
  • [8] Novel electrochemical sensing platform for detection of hydrazine based on modified screen-printed graphite electrode
    Mousazadeh, Farideh
    Mohammadi, Sayed Zia
    Mohammadhasani-Pour, Maryam
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2024, 14 (01): : 107 - 118
  • [9] Electrochemical sensing of Sudan I using the modified graphite screen-printed electrode
    Tajik, Somayeh
    Beitollahi, Hadi
    Nejad, Fariba Garkani
    Safaei, Mohadeseh
    Jahani, Peyman Mohammadzadeh
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (07) : 1477 - 1490
  • [10] Screen-printed diamond electrode: A disposable sensitive electrochemical electrode
    Kondo, Takeshi
    Sakamoto, Hironori
    Kato, Takayoshi
    Horitani, Masaru
    Shitanda, Isao
    Itagaki, Masayuki
    Yuasa, Makoto
    ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (12) : 1546 - 1549