Analysis of Electromagnetic Stresses and Structural Integrity on the Winding of a Transformer Under Inrush Currents Conditions

被引:0
|
作者
Fonseca, W. S. [1 ,2 ]
Lima, D. S. [1 ,2 ]
Nunes, M. V. A. [1 ,2 ]
Soeiro, N. S. [1 ,2 ]
Lima, A. K. F. [1 ]
机构
[1] Fed Univ Para, Univ Campus Tucurui, Tucurui, Para, Brazil
[2] Technol Inst, Belem, Para, Brazil
关键词
Transformers; Electromagnetic Stresses; Inrush Currents;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The objective of this paper is to assist in the investigation of electromagnetic forces during faults inside the transformers as a result of transient states. The methodology is based on modeling a single-phase 50 MVA transformer subjected to inrush currents through finite element method (FEM). In this perspective, the conditions of inrush currents are used to estimate the magnetic field density dispersion in the transformer and to find the values of forces in axial and radial directions. These components are distributed along the energized windings for observing the loads in high-voltage windings. Thus, this article will present investigations of electromagnetic forces, structural deformation, stresses, and safety factor on the winding of transformers when subjected to inrush current.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Study on Electromagnetic-Mechanical Coupling Effect of Transformer Winding under Short Circuit
    Ma, Cheng
    Zhang, Fan
    Zhan, Jiangyang
    Jin, Lingfeng
    Yang, Zhi
    Liang, Suning
    2022 9TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2022, : 736 - 741
  • [22] Electric stresses on transformer winding insulation under standard and non-standard impulse voltages
    Bhuyan, Kaveri
    Chatterjee, Saibal
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 123 : 40 - 47
  • [23] Winding vibration analysis of unbalanced transformer based on electromagnetic-mechanical coupling
    Pan, Chao
    Wang, Chengjian
    Liu, Ziming
    Chen, Xiang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 134
  • [24] Modeling and analysis of a single-phase core-type transformer under inrush current and nonlinear load conditions
    Hüseyin Altun
    Sedat Sünter
    Ömür Aydoğmuş
    Electrical Engineering, 2021, 103 : 2961 - 2972
  • [25] Analysis of internal winding stresses in EHV generator step-up transformer failures
    Morched, AS
    Marti, L
    Brierley, RH
    Lackney, JG
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (02) : 888 - 894
  • [26] Modeling and analysis of a single-phase core-type transformer under inrush current and nonlinear load conditions
    Altun, Huseyin
    Sunter, Sedat
    Aydogmus, Omur
    ELECTRICAL ENGINEERING, 2021, 103 (06) : 2961 - 2972
  • [27] Applicability Analysis of Traditional T-equivalent Leakage Inductance of Three-winding Transformer in Inrush Process
    Cao W.
    Yin X.
    Zhang Z.
    Pan Y.
    Chen Y.
    Wang Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (08): : 2680 - 2690
  • [28] STUDIES ON STRUCTURAL INTEGRITY FOR SEPARATE-COOLING SHEET-WINDING GAS-INSULATED TRANSFORMER
    GOTO, K
    YAMAZAKI, T
    HIROSE, H
    MURAKAMI, T
    IKEDA, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (02) : 1079 - 1086
  • [29] Low Second-Harmonic Content in Transformer Inrush Currents - Analysis and Practical Solutions for Protection Security
    Hodder, Steven
    Kasztenny, Bogdan
    Fischer, Nonnann
    Xia, Yu
    2014 67TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2014, : 705 - 722
  • [30] Computer-Aided Electromagnetic Analysis of a Multi-Winding Transformer for SST Applications
    Quevedo, Richard
    Sanchez, Alberto
    2019 IEEE CHILEAN CONFERENCE ON ELECTRICAL, ELECTRONICS ENGINEERING, INFORMATION AND COMMUNICATION TECHNOLOGIES (CHILECON), 2019,