Effect of pulsatile perfusion during cardiopulmonary bypass in terms of radial artery sphygmogram

被引:2
|
作者
Zhang, Zhifeng [1 ]
Xu, Jiatuo [1 ]
Zhu, Enyuan [1 ]
Zhang, Qi [2 ]
Yu, Lu [2 ]
Qiu, Yongbing [1 ]
Tang, Jianguo [1 ]
Fei, Zhaofu [1 ]
Li, Xin [3 ]
Tu, Liping [1 ]
Han, Chouping [1 ]
Liu, Ying [1 ]
Guo, Zhen [3 ]
Zhou, Changle [1 ]
Shi, Meiyu [1 ]
Qian, Yingxin [1 ]
Bao, Yimin [1 ]
Ji, Xinming [2 ]
机构
[1] Shanghai Univ Tradit Chinese Med, Basic Med Sci Sch, Shanghai 201203, Peoples R China
[2] Fudan Univ, Dept Microelect, Shanghai 200433, Peoples R China
[3] Shanghai Jiao Tong Univ, Dept Cardiopulmonary Bypass, Shanghai Chest Hosp, Shanghai 200030, Peoples R China
基金
中国国家自然科学基金;
关键词
Cardiopulmonary bypass; Pulsatile flow; Radial artery; Pulse waveforms; Sphygmogram; OXYGEN-SATURATION; BLOOD-FLOW; PRESERVATION; SURGERY; PUMP;
D O I
10.1016/S0254-6272(15)30081-9
中图分类号
R [医药、卫生];
学科分类号
10 ;
摘要
OBJECTIVE: To investigate a quantitative method for using radial artery pulse waveforms to assess the effect of pulsatile flow during cardiopulmonary bypass (CPB). METHODS: A total of 34 adults with heart disease who underwent open-heart surgery between April 2010 and January 2011 were randomized into a pulsatile perfusion group (n=17) and a non-pulsatile perfusion group (n=17). Radial arterial pulse waveforms of pulsatile and non-pulsatile perfusion patients were observed and compared before and during CPB. RESULTS: No pulse waveform could be detected at patients' radial artery in both groups when the aorta was cross-clamped. Pulse waveforms could be detected at pulsatile perfusion patients' radial artery, but could not be detected at non-pulsatile perfusion patients' radial artery during CPB. Additionally, patients' pulse waveforms during pulsatile perfusion were lower than those before the operation. CONCLUSION: Our findings indicate that radial artery sphygmogram can be used as a valid indicator to evaluate the effectiveness of pulsatile perfusion during CPB. (C) 2014 JTCM. All rights reserved.
引用
收藏
页码:673 / 677
页数:5
相关论文
共 50 条
  • [11] Pulmonary artery perfusion versus no pulmonary perfusion during cardiopulmonary bypass
    Buggeskov, Katrine Bredahl
    DANISH MEDICAL JOURNAL, 2018, 65 (03):
  • [12] Direct Observation of the Human Microcirculation During Cardiopulmonary Bypass: Effects of Pulsatile Perfusion
    Elbers, Paul W. G.
    Wijbenga, Jeroen
    Solinger, Frank
    Yilmaz, Aladdin
    van Iterson, Mat
    van Dongen, Eric P. A.
    Ince, Can
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (02) : 250 - 255
  • [13] Clinical Application of Pulsatile Perfusion During Cardiopulmonary Bypass In Pediatric Heart Surgery
    Zhao, Ju
    Liu, Jin-Ping
    Feng, Zheng-Yi
    Liu, Ying-Long
    Li, Shou-Jun
    Long, Cun
    ASAIO JOURNAL, 2009, 55 (03) : 300 - 303
  • [14] Comparison of six pediatric cardiopulmonary bypass pumps during pulsatile and nonpulsatile perfusion
    Ündar, A
    Eichstaedt, HC
    Masai, T
    Yang, SQ
    Bigley, JE
    McGarry, MC
    Mueller, M
    Vaughn, WK
    Fraser, CD
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (04): : 827 - 829
  • [15] Pulsatile perfusion during cardiopulmonary bypass procedures in neonates, infants, and small children
    Rider, Alan R.
    Schreiner, Robert S.
    Uendar, Akif
    ASAIO JOURNAL, 2007, 53 (06) : 706 - 709
  • [16] Pulsatile pulmonary perfusion during cardiopulmonary bypass reduces the pulmonary inflammatory response
    Siepe, Matthias
    Goebel, Ulrich
    Mecklenburg, Anne
    Doenst, Torsten
    Benk, Christoph
    Stein, Philipp
    Beyersdorf, Friedhelm
    Loop, Torsten
    Schlensak, Christian
    ANNALS OF THORACIC SURGERY, 2008, 86 (01): : 115 - 122
  • [17] PULSATILE PERFUSION DURING HYPOTHERMIC CARDIOPULMONARY BYPASS SIGNIFICANTLY INFLUENCES MORBIDITY AND MORTALITY AFTER CORONARY-ARTERY BYPASS-SURGERY
    MURKIN, JM
    MARTZKE, JS
    BUCHAN, AM
    SHARMA, DS
    CAMPBELL, P
    BENTLEY, CA
    ANESTHESIA AND ANALGESIA, 1993, 76 (02): : S280 - S280
  • [18] Effective Pulmonary Artery Perfusion Mode during Cardiopulmonary Bypass
    Zhang, Renteng
    Wang, Zengwei
    Wang, Huishan
    Song, Hengchang
    Zhang, Nanbin
    Fang, Minhua
    HEART SURGERY FORUM, 2011, 14 (01): : E18 - E21
  • [19] THE EFFECT OF PULSATILE CARDIOPULMONARY BYPASS ON LIMB BLOOD-FLOW AND TISSUE PERFUSION
    FARACI, PA
    DAVIS, JP
    DALY, BDT
    CLEVELAND, RJ
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1983, 29 : 511 - 515
  • [20] Optimal pulmonary artery perfusion mode and perfusion pressure during cardiopulmonary bypass
    Zhang, R.
    Wang, Z.
    Wang, H.
    Song, H.
    Zhang, N.
    Fang, M.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2010, 51 (03): : 435 - 442