Energy expenditure in critically ill patients estimated by population-based equations, indirect calorimetry and CO2-based indirect calorimetry

被引:27
|
作者
Rousing, Mark Lillelund [1 ]
Hahn-Pedersen, Mie Hviid [1 ]
Andreassen, Steen [1 ]
Pielmeier, Ulrike [1 ]
Preiser, Jean-Charles [2 ]
机构
[1] Aalborg Univ, Ctr Model Based Med Decis Support MMDS, Dept Hlth Sci & Technol, Fredrik Bajers Vej 7E, DK-9220 Aalborg, Denmark
[2] Univ Libre Bruxelles, Dept Intens Care, Erasme Univ Hosp, 808 Route Lennik, B-1070 Brussels, Belgium
来源
关键词
Energy expenditure; Metabolic rate; Caloric intake; Nutritional support; Critically ill; Indirect calorimetry; Respiratory quotient; VCO2; RESTING METABOLIC-RATE; NUTRITION SUPPORT; ENTERAL NUTRITION; GUIDELINES; PROVISION; CONSENSUS; ACCURACY; ADULTS; TIME;
D O I
10.1186/s13613-016-0118-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Indirect calorimetry (IC) is the reference method for measurement of energy expenditure (EE) in mechanically ventilated critically ill patients. When IC is unavailable, EE can be calculated by predictive equations or by VCO2-based calorimetry. This study compares the bias, quality and accuracy of these methods. Methods: EE was determined by IC over a 30-min period in patients from a mixed medical/postsurgical intensive care unit and compared to seven predictive equations and to VCO2-based calorimetry. The bias was described by the mean difference between predicted EE and IC, the quality by the root mean square error (RMSE) of the difference and the accuracy by the number of patients with estimates within 10 % of IC. Errors of VCO2-based calorimetry due to choice of respiratory quotient (RQ) were determined by a sensitivity analysis, and errors due to fluctuations in ventilation were explored by a qualitative analysis. Results: In 18 patients (mean age 61 +/- 17 years, five women), EE averaged 2347 kcal/day. All predictive equations were accurate in less than 50 % of the patients with an RMSE >= 15 %. VCO2-based calorimetry was accurate in 89 % of patients, significantly better than all predictive equations, and remained better for any choice of RQ within published range (0.76-0.89). Errors due to fluctuations in ventilation are about equal in IC and VCO2-based calorimetry, and filtering reduced these errors. Conclusions: This study confirmed the inaccuracy of predictive equations and established VCO2-based calorimetry as a more accurate alternative. Both IC and VCO2-based calorimetry are sensitive to fluctuations in respiration.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [21] Indirect Calorimetry Better Identifies Energy Needs in Critically Ill Cardiothoracic Patients
    Ratzlaff, Robert
    Nowak, Diane
    Hata, J.
    Gordillo, Desiree
    Cresci, Gail
    Uhrin, Donna
    Putnam, James
    Faulhaber, Kevin
    CRITICAL CARE MEDICINE, 2013, 41 (12)
  • [22] WALKING AND RUNNING ENERGY-EXPENDITURE ESTIMATED BY CALTRAC AND INDIRECT CALORIMETRY
    HAYMES, EM
    BYRNES, WC
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1993, 25 (12): : 1365 - 1369
  • [23] The use of circulatory indirect calorimetry in critically ill patients.
    LaraCastro, C
    Heini, A
    Morgan, SL
    FASEB JOURNAL, 1996, 10 (03): : 4727 - 4727
  • [24] Comparison of indirect calorimetry, the Fick method, and prediction equations in estimating the energy requirements of critically ill patients
    Flancbaum, L
    Choban, PS
    Sambucco, S
    Verducci, J
    Burge, JC
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1999, 69 (03): : 461 - 466
  • [25] ENERGY EXPENDITURE IN MECHANICALLY VENTILATED PATIENTS: INDIRECT CALORIMETRY VS PREDICTIVE EQUATIONS
    Sungurtekin, H.
    Karakuzu, S.
    Serin, S.
    ANESTHESIA AND ANALGESIA, 2016, 123 : 169 - 169
  • [26] Energy Expenditure in Mechanically Ventilated Patients: Indirect Calorimetry vs Predictive Equations
    Sungurtekin, Hulya
    Karakuzu, Serdar
    Serin, Simay
    JOURNAL OF MEDICAL AND SURGICAL INTENSIVE CARE MEDICINE, 2019, 10 (01): : 7 - 12
  • [27] Comparing indirect respiratory (IRC) and indirect circulatory (ICC) calorimetry in critically ill patients
    Rocha, EM
    Abrahäo, V
    Ananias, M
    Rosenfeld, RS
    Cardoso, FP
    Carpenter, LF
    Miranda, FG
    Säo José, CS
    CRITICAL CARE MEDICINE, 1999, 27 (01) : A116 - A116
  • [28] Indirect Calorimetry Measurements Compared With Guideline Weight-Based Energy Calculations in Critically Ill Stroke Patients
    Smetana, Keaton S.
    Hannawi, Yousef
    May, Casey C.
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2021, 45 (07) : 1484 - 1490
  • [29] Erratum to: Can calculation of energy expenditure based on CO2 measurements replace indirect calorimetry?
    Taku Oshima
    Séverine Graf
    Claudia-Paula Heidegger
    Laurence Genton
    Jérôme Pugin
    Claude Pichard
    Critical Care, 21
  • [30] The thermodilution technique for measuring resting energy expenditure does not agree with indirect calorimetry for the critically ill patient
    Ogawa, AM
    Shikora, SA
    Burke, LM
    Heetderks-Cox, JE
    Bergren, CT
    Muskat, PC
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1998, 22 (06) : 347 - 351