Calculation of the external quality factor of the high power input coupler for the BEPC II superconducting cavity

被引:2
|
作者
Huang Tong-Ming [1 ]
Pan Wei-Min [1 ]
Wang Guang-Wei [1 ]
Furuya, T. [2 ]
Mitsunobu, S. [2 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[2] KEK, Tsukuba, Ibaraki 3050801, Japan
关键词
high power input coupler; external quality factor; superconducting cavity;
D O I
10.1088/1674-1137/32/1/016
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
It is very important to predict the coupling between the cavity and the high power input source in the coupler design. In this paper, a time domain method is used to calculate the external quality factor Q(ext) for the BEPC II superconducting cavity. A comparison between simulation results and experimental results is presented. The results of simulation and measurement of Q(ext) have a good agreement within an error of 10%. The geometry parameters related with Q(ext) are also studied.
引用
收藏
页码:72 / 74
页数:3
相关论文
共 50 条
  • [21] A tunable waveguide to cavity coupler for high power accelerator cavities
    Kumar, Rajesh
    Singh, P.
    Unnikrishnan, Divya
    Kumar, Girish
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 664 (01): : 203 - 213
  • [22] Thermal analysis for fundamental power coupler of HALF 499.8MHz superconducting cavity
    Tang, Y.
    Wu, C-F
    Wang, L.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (06)
  • [23] Coupler conditioning and high power testing of ADS Spoke cavity
    陈旭
    孟繁博
    马强
    黄彤明
    林海英
    潘卫民
    Chinese Physics C, 2014, (02) : 73 - 75
  • [24] Mitigation of multipacting, enhanced by gas condensation on the high power input coupler of a superconducting RF module, by comprehensive warm aging
    Wang, Chaoen
    Chang, Lung-Hai
    Chang, Mei-Hsia
    Chen, Ling-Jhen
    Chung, Fu-Tsai
    Lin, Ming-Chyuan
    Liu, Zong-Kai
    Lo, Chih-Hung
    Tsai, Chi-Lin
    Yeh, Meng-Shu
    Yu, Tsung-Chi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 872 : 150 - 159
  • [25] Coupler conditioning and high power testing of ADS Spoke cavity
    Chen Xu
    Meng Fan-Bo
    Ma Qiang
    Huang Tong-Ming
    Lin Hai-Ying
    Pan Wei-Min
    CHINESE PHYSICS C, 2014, 38 (02)
  • [26] Coupler conditioning and high power testing of ADS Spoke cavity
    陈旭
    孟繁博
    马强
    黄彤明
    林海英
    潘卫民
    Chinese Physics C, 2014, 38 (02) : 73 - 75
  • [27] Development of high power waveguide valve for BEPC II-Linac
    Zhao, Feng-Li
    Liu, Jin-Tong
    Zhou, Yao-Xiang
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2006, 18 (02): : 297 - 299
  • [28] High power external cavity semiconductor laser
    Dong, Qiming
    Pan, Zhongqi
    Zhang, Hanyi
    Yang, Jinqiang
    Zhou, Bingkun
    Zhongguo Jiguang/Chinese Journal of Lasers, 1998, 25 (07): : 584 - 586
  • [29] Development and Integration Testing of a Power Coupler for a 3.9-GHz Superconducting Multicell Cavity Resonator
    Li, Jianjian
    Harms, Elvin R., Jr.
    Hocker, Andy
    Khabiboulline, Timergali N.
    Solyak, Nikolay
    Wong, Thomas T. Y.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (01) : 21 - 26
  • [30] A coaxial HOM coupler for a superconducting RF cavity and its low-power measurement results
    Sun An
    Tang Ya-Zhe
    Zhang Li-Ping
    Li Ying-Min
    Kim, Han-Sung
    CHINESE PHYSICS C, 2011, 35 (03) : 301 - 307