Reproducibility of macular thickness and volume using zeiss optical coherence tomography in patients with diabetic macular edema

被引:111
|
作者
Krzystolik, Magdalena G. [1 ]
Strauber, Samara F. [1 ]
Ai-ello, Lloyd Paul [1 ]
Beek, Roy W. [1 ]
Berger, Brian B. [1 ]
Bressler, Neil M. [1 ]
Browning, David J. [1 ]
Chambers, Robert B. [1 ]
Danis, Ronald P. [1 ]
Davis, Matthew D. [1 ]
Glassman, Adam R. [1 ]
Gonzalez, Victor H. [1 ]
Greenberg, Paul B. [1 ]
Gross, Jeffrey G. [1 ]
Kim, Judy E. [1 ]
Kollman, Craig [1 ]
机构
[1] Jaeb Ctr Hlth Res, Tampa, FL 33647 USA
关键词
D O I
10.1016/j.ophtha.2006.10.055
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate optical coherence tomography (OCT) reproducibility in patients with diabetic macular edema (DME). Design: Prospective 1-day observational study. Participants: Two hundred twelve eyes of 107 patients with DME involving the macular center by clinical examination and OCT central subfield thickness of >= 225 mu m. Methods: Retinal thickness was measured with the OCT3 system, and scans were evaluated by a reading center. Reproducibility of retinal thickness measurements was assessed, and 95% confidence intervals (CIs) for a change in thickness were estimated. Main Outcome Measures: Reproducibility of OCT-measured central subfield thickness. Results: Reproducibility was better for central subfield thickness than for center point thickness (half-width of the 95% CI for absolute change, 38 mu m vs. 50 mu m, and for relative change, 11 % vs. 17%, respectively; P<0.001). The median absolute difference between replicate measurements of the central subfield was 7 mu m (2%). Half-widths of the 95% CI for a change in central subfield thickness were 22, 23, 33, and 56 mu m for scans with central subfield thicknesses of <200, 200 to <250, 250 to <400, and >= 400 mu m, respectively. When expressed as percentage differences between 2 measurements, half-widths of the 95% CI for a change in central subfield thickness were 10%, 10%, 10%, and 13% for scans with central subfield thicknesses of <200, 200 to <250, 250 to <400, and >= 400 mu m, respectively. We were unable to identify an effect on reproducibility of central subfield measurements with respect to the presence of cystoid abnormalities, subretinal fluid, vitreomacular traction, or reduced visual acuity. Reproducibility was better when both scans had a standard deviation (SD) of the center point of <10.0% (half-width of the 95% CI for change, 33 mu m vs. 56 mu m; P<0.001). Conclusions: Reproducibility is better for central subfield thickness measurements than for center point measurements, and variability is less with retinal thickness when expressed as a percent change than when expressed as an absolute change. A change in central subfield thickness exceeding 11% is likely to be real. Scans with an SD of the center point of >= 10.0% are less reproducible and should be viewed with caution when assessing the validity of an observed change in retinal thickness inpatients with DME.
引用
收藏
页码:1520 / 1525
页数:6
相关论文
共 50 条
  • [31] Wide-Field Optical Coherence Tomography in Patients with Diabetic Macular Edema
    Kicinski, Krzysztof
    Gawecki, Maciej
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (14)
  • [32] Microvascular changes in patients with diabetic macular edema on optical coherence tomography angiography
    Domanian, A.
    Schreur, V.
    Liefers, B.
    Phan, M.
    Hoyng, C.
    Klevering, B. J.
    de Jong, E.
    Theelen, T.
    [J]. ACTA OPHTHALMOLOGICA, 2017, 95 : 20 - 21
  • [33] Diabetic Macular Edema Characterization and Visualization Using Optical Coherence Tomography Images
    Vidal, Placido L.
    de Moura, Joaquim
    Diaz, Macarena
    Novo, Jorge
    Ortega, Marcos
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (21): : 1 - 23
  • [34] Consistency of ocular coherence tomography fast macular thickness mapping in diabetic diffuse macular edema
    Saraiva, Fabio Petersen
    Costa, Patricia Grativol
    Inomata, Daniela Lumi
    Melo, Carlos Sergio Nascimento
    Helal, John, Jr.
    Nakashima, Yoshitaka
    [J]. CLINICS, 2007, 62 (06) : 721 - 724
  • [35] Reproducibility of macular thickness mapping on the commercial optical coherence tomography device
    MacNutt, JM
    Schuman, JS
    Guedes, VRF
    Miller, VM
    Pakter, HM
    Ghanta, RK
    Drexler, W
    Hertzmark, E
    Peiris, ID
    Puliafito, CA
    Fujimoto, JG
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S125 - S125
  • [36] Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography
    Bruce, Alison
    Pacey, Ian E.
    Dharni, Poonam
    Scally, Andy J.
    Barrett, Brendan T.
    [J]. OPEN OPHTHALMOLOGY JOURNAL, 2009, 3 : 10 - 14
  • [37] Quantitative evaluation of macular thickness in normal and diabetic patients using optical coherence tomography.
    Haouchine, B
    Massin, P
    Erginay, A
    Paques, M
    Gaudric, A
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S654 - S654
  • [38] Optical coherence tomography image for automatic classification of diabetic macular edema
    Wang, Ping
    Li, Jia-Li
    Ding, Hao
    [J]. OPTICA APPLICATA, 2020, 50 (04) : 567 - 577
  • [39] Clinical application of optical coherence tomography angiography in diabetic macular edema
    Lv, Meng
    Li, Tuo
    Li, Yin
    [J]. AFRICAN HEALTH SCIENCES, 2023, 23 (02) : 484 - 489
  • [40] Role of Inflammation in Classification of Diabetic Macular Edema by Optical Coherence Tomography
    Chung, Yoo-Ri
    Kim, Young Ho
    Ha, Seong Jung
    Byeon, Hye-Eun
    Cho, Chung-Hyun
    Kim, Jeong Hun
    Lee, Kihwang
    [J]. JOURNAL OF DIABETES RESEARCH, 2019, 2019