The Utility of Multidetector-Row Computed Tomography Angiography for Evaluating Perforators of Fibular Osteocutaneous Flaps

被引:6
|
作者
Satoh, Takashi [1 ]
Kimata, Yoshihiro [2 ]
Hasegawa, Kenjiro [2 ]
Namba, Yuzaburo [2 ]
机构
[1] Kyorin Univ, Sch Med, Dept Plast & Reconstruct Surg, Tokyo 1818611, Japan
[2] Okayama Univ, Dept Plast Reconstruct Surg, Okayama, Japan
关键词
Fibular osteocutaneous flap; perforator; MDCT angiography; preoperative imaging; PREOPERATIVE LEG ANGIOGRAPHY; ANTEROLATERAL THIGH FLAP; CT ANGIOGRAPHY; RECONSTRUCTION; DOPPLER; NEED;
D O I
10.1055/s-0030-1267380
中图分类号
R61 [外科手术学];
学科分类号
摘要
Multidetector-row computed tomography angiography (MDCTA) can be used to visualize small vessels and has been used to search for perforators in deep inferior epigastric artery perforator flaps and anterolateral thigh flaps. Fibula osteocutaneous flaps are often used for mandibular reconstruction, but questions remain about the reliability of these flaps and the variety of their perforators. Eight patients who were candidates for mandibular or pedal reconstruction with a fibula osteocutaneous flap were prospectively evaluated with MDCTA and Doppler sonography. We evaluated the number, position, and course of perforators with MDCTA. The perforators were classified, and intraoperative findings were compared with those of Doppler sonography and MDCTA. MDCTA accurately identified the perforators and showed a satisfactory concordance with intraoperative findings. The high spatial resolution of MDCTA allows the perforators' origin, course, and type to be precisely described. Eighteen vessels were identified with MDCTA, and on average, 2.3 vessels were identified in the leg of each patient. The rate of concordance with operative findings was 87.5% for MDCTA. With MDCTA, flap perforators can be accurately evaluated before surgery in a manner not possible with traditional angiography or Doppler sonography. Reliable perforators can be chosen, and detailed operative plans can be made.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 50 条
  • [41] Occlusion of coronary aneurysms demonstrated by multidetector-row computed tomography
    Sei Komatsu
    Stephan Achenbach
    Dieter Ropers
    Werner G. Daniel
    Yasunori Ueda
    Tobias Pflederer
    Alexander Kuhlmann
    Martin Wechsel
    Atsushi Hirayama
    Kazuhisa Kodama
    Clinical Research in Cardiology, 2007, 96 : 575 - 578
  • [42] Cardiac multidetector-row computed tomography in patients with unstable angina
    Dirksen, MS
    Jukema, JW
    Bax, JJ
    Lamb, HJ
    Boersma, E
    Tuinenburg, JC
    Geleijns, J
    van der Wall, EE
    de Roos, A
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (04): : 457 - 461
  • [43] Multidetector-row computed tomography in suspected pulmonary embolism - Reply
    Perrier, A
    Roy, PM
    Meyer, G
    NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (06): : 630 - 631
  • [44] Multidetector-row computed tomography management of acute pulmonary embolism
    Yasui, Takahiro
    Tanabe, Nobuhiro
    Terada, Jiro
    Yanagawa, Noriyuki
    Shimizu, Hidefumi
    Matsubara, Hiroshi
    Hoshino, Susumu
    Fujikawa, Ayako
    Mizuno, Satoko
    Yatomi, Mari
    Sakao, Seiichiro
    Uruma, Takahiro
    Kasahara, Yasunori
    Takiguchi, Yuichi
    Tatsumi, Koichiro
    Kuriyama, Takayuki
    CIRCULATION JOURNAL, 2007, 71 (12) : 1948 - 1954
  • [45] Clinical significance of multidetector-row computed tomography in breast surgery
    Doihara, Hiroyoshi
    Fujita, Takeo
    Takabatake, Daisuke
    Takahashi, Hirotoshi
    Ogasawara, Yutaka
    Shimizu, Nobuyoshi
    BREAST JOURNAL, 2006, 12 (05): : S204 - S209
  • [46] Application of Multidetector-Row Computed Tomography in Propeller Flap Planning
    Ono, Shimpei
    Chung, Kevin C.
    Hayashi, Hiromitsu
    Ogawa, Rei
    Takami, Yoshihiro
    Hyakusoku, Hiko
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2011, 127 (02) : 703 - 711
  • [47] Visualization of the azygos arch valves on multidetector-row computed tomography
    Tamaki Ichikawa
    Jun Endo
    Jun Koizumi
    Ayako Ro
    Makiko Kobayashi
    Midori Saito
    Shuichi Kawada
    Takeshi Hashimoto
    Yutaka Imai
    Heart and Vessels, 2008, 23 : 118 - 123
  • [48] The Value of Multidetector Row Computed Tomography Angiography for Preoperative Planning of Freestyle Pedicled Perforator Flaps
    Yang, Si-Fen
    Wang, Chun-Mei
    Ono, Shimpei
    Xu, Wei
    Xu, Kai-Yuan
    Pu, Lee L. Q.
    ANNALS OF PLASTIC SURGERY, 2016, 77 (06) : 669 - 673
  • [49] Multidetector-row computed tomography diagnostic accuracy in the real world of cardiology: a comparison with invasive coronary angiography
    Sirol, M.
    Sanz, J. S.
    Dellagrotaglie, S.
    Poon, M.
    Fuster, V.
    Rajagopalan, S.
    Leber, A. W.
    EUROPEAN HEART JOURNAL, 2006, 27 : 428 - 429
  • [50] Multidetector-row computed tomography coronary angiography - Optimization of image reconstruction phase according to the heart rate
    Nagatani, Yukihiro
    Takahashi, Masashi
    Takazakura, Ryutaro
    Nitta, Norihisa
    Murata, Kiyoshi
    Ushio, Noritoshi
    Matsuo, Shinto
    Yamamoto, Takashi
    Horie, Minoru
    CIRCULATION JOURNAL, 2007, 71 (01) : 112 - 121