Improved Interventional X-ray Appearance

被引:0
|
作者
Wang, Xiang [1 ]
Berge, Christian Schulte Zu [1 ]
Demirci, Stefanie [1 ]
Fallavollita, Pascal [1 ]
Navab, Nassir [1 ]
机构
[1] Tech Univ Munich, D-80290 Munich, Germany
关键词
Medical image visualization; depth perception; image-guided interventions; GPU ray casting; transfer function; C.1.2 [Computing Methodologies]: Computer Graphics; Graphics systems and interfaces; J.5.2 [Human Centered Computing]: Visualization; Visualization application domains; ENHANCING DEPTH-PERCEPTION; 2D-3D REGISTRATION; COLOR MAPS;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Depth cues are an essential part of navigation and device positioning tasks during clinical interventions. Yet, many minimally-invasive procedures, such as catheterizations, are usually performed under X-ray guidance only depicting a 2D projection of the anatomy, which lacks depth information. Previous attempts to integrate pre-operative 3D data of the patient by registering these to intra-operative data have led to virtual 3D renderings independent of the original X-ray appearance and planar 2D color overlays (e.g. roadmaps). A major drawback associated to these solutions is the trade-off between X-ray attenuation values that is completely neglected during 3D renderings, and depth perception not being incorporated into the 2D roadmaps. This paper presents a novel technique for enhancing depth perception of interventional X-ray images preserving the original attenuation appearance. Starting from patient-specific pre-operative 3D data, our method relies on GPU ray casting to compute a colored depth map, which assigns a predefined color to the first incidence of gradient magnitude value above a predefined threshold along the ray. The colored depth map values are carefully integrated into the X-Ray image while maintaining its original grey-scale intensities. The presented method was tested and analysed for three relevant clinical scenarios covering different anatomical aspects and targeting different levels of interventional expertise. Results demonstrate that improving depth perception of Xray images has the potential to lead to safer and more efficient clinical interventions.
引用
收藏
页码:237 / 242
页数:6
相关论文
共 50 条
  • [41] An improved method for inspection of solder joints using X-ray laminography and X-ray microtomography
    Kalukin, AR
    Sankaran, V
    Chartrand, B
    Millard, DL
    Kraft, RP
    Embrechts, MJ
    NINETEENTH IEEE/CPMT INTERNATIONAL ELECTRONICS MANUFACTURING TECHNOLOGY SYMPOSIUM - PROCEEDINGS, 1996 IEMT SYMPOSIUM, 1996, : 438 - 445
  • [42] AN IMPROVED LIGHT LOCALIZER FOR X-RAY THERAPY
    GRIMMETT, LG
    FLETCHER, GH
    MOORE, EB
    RADIOLOGY, 1954, 62 (04) : 589 - 593
  • [43] IMPROVED X-RAY SERVICE FOR LARGE HOSPITALS
    CLIFTON, VK
    AUSTRALASIAN RADIOLOGY, 1972, 16 (01): : 35 - &
  • [44] Improved x-ray switched XeCl laser
    van Goor, F.A., 1600, (75):
  • [45] IMPROVED RESOLUTION X-RAY PHOTOGRAPHS OF SUN
    RUSSELL, PC
    POUNDS, KA
    NATURE, 1966, 209 (5022) : 490 - &
  • [46] An improved X-ray detector for use at synchrotrons
    Thoms, M
    Bauchau, S
    Hausermann, D
    Kunz, M
    Le Bihan, T
    Mezouar, M
    Strawbridge, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 413 (01): : 175 - 184
  • [47] AN IMPROVED X-RAY SHADOW PROJECTION MICROSCOPE
    COSSLETT, VE
    PEARSON, HE
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1954, 31 (07): : 255 - 257
  • [48] Improved radiography with polycapillary x-ray optics
    MacDonald, CA
    Sugiro, FR
    Gibson, WM
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS II, 2001, 4502 : 10 - 18
  • [49] IMPROVED X-RAY SWITCHED XECL LASER
    VANGOOR, FA
    TRENTELMAN, M
    TIMMERMANS, JCM
    WITTEMAN, WJ
    JOURNAL OF APPLIED PHYSICS, 1994, 75 (01) : 621 - 623
  • [50] An improved X-ray tube for diffraction analysis
    Machlett, RR
    JOURNAL OF APPLIED PHYSICS, 1942, 13 (06) : 398 - 401