Improved Interventional X-ray Appearance

被引:0
|
作者
Wang, Xiang [1 ]
Berge, Christian Schulte Zu [1 ]
Demirci, Stefanie [1 ]
Fallavollita, Pascal [1 ]
Navab, Nassir [1 ]
机构
[1] Tech Univ Munich, D-80290 Munich, Germany
关键词
Medical image visualization; depth perception; image-guided interventions; GPU ray casting; transfer function; C.1.2 [Computing Methodologies]: Computer Graphics; Graphics systems and interfaces; J.5.2 [Human Centered Computing]: Visualization; Visualization application domains; ENHANCING DEPTH-PERCEPTION; 2D-3D REGISTRATION; COLOR MAPS;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Depth cues are an essential part of navigation and device positioning tasks during clinical interventions. Yet, many minimally-invasive procedures, such as catheterizations, are usually performed under X-ray guidance only depicting a 2D projection of the anatomy, which lacks depth information. Previous attempts to integrate pre-operative 3D data of the patient by registering these to intra-operative data have led to virtual 3D renderings independent of the original X-ray appearance and planar 2D color overlays (e.g. roadmaps). A major drawback associated to these solutions is the trade-off between X-ray attenuation values that is completely neglected during 3D renderings, and depth perception not being incorporated into the 2D roadmaps. This paper presents a novel technique for enhancing depth perception of interventional X-ray images preserving the original attenuation appearance. Starting from patient-specific pre-operative 3D data, our method relies on GPU ray casting to compute a colored depth map, which assigns a predefined color to the first incidence of gradient magnitude value above a predefined threshold along the ray. The colored depth map values are carefully integrated into the X-Ray image while maintaining its original grey-scale intensities. The presented method was tested and analysed for three relevant clinical scenarios covering different anatomical aspects and targeting different levels of interventional expertise. Results demonstrate that improving depth perception of Xray images has the potential to lead to safer and more efficient clinical interventions.
引用
收藏
页码:237 / 242
页数:6
相关论文
共 50 条
  • [1] X-RAY EXAMINATION WITH AN IMPROVED X-RAY TELEVISION UNIT
    MATSUDA, H
    NAKAHORI, T
    NAKAI, A
    SOHMA, J
    NINOMIYA, K
    NAGAOKA, T
    TAKAI, G
    AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1963, 89 (02): : 432 - &
  • [2] AN IMPROVED X-RAY STAND
    KLEIN, I
    RADIOLOGY, 1955, 65 (03) : 420 - 421
  • [3] AN IMPROVED X-RAY PHOTOTIMER
    HODGES, PC
    JENKINS, RT
    WILLIAMS, SF
    RADIOLOGY, 1950, 54 (01) : 64 - 73
  • [4] IMPROVED X-RAY TOPOGRAPHY
    FITZPATR.RL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (09): : 1350 - &
  • [5] X-RAY APPEARANCE OF INTRAUTERINE CONTRACEPTIVE DEVICES
    LEHFELDT, H
    FERTILITY AND STERILITY, 1965, 16 (04) : 502 - &
  • [6] Sudden appearance of a mass on chest X-ray
    Ledrick, D
    Khalil, H
    Tita, J
    Mahajan, V
    POSTGRADUATE MEDICAL JOURNAL, 1998, 74 (870) : 245 - 246
  • [7] OPTICAL APPEARANCE OF BINARY X-RAY SOURCES
    PRINGLE, JE
    NATURE-PHYSICAL SCIENCE, 1973, 243 (128): : 90 - 94
  • [8] The appearance of atoms as determined by x-ray scattering
    Wollan, EO
    Compton, AH
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1934, 24 (09) : 229 - 233
  • [9] Wavelets, local tomography and interventional X-ray imaging
    Bilgot, A
    Perrier, V
    Desbat, L
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3505 - 3509
  • [10] Improved pyroelectric X-ray generator for planetary active X-ray spectroscopy
    Naito, Masayuki
    Hasebe, Nobuyuki
    Nagaoka, Hiroshi
    Oshima, Yusuke
    Mizone, Miho
    Shibamura, Eido
    Kuno, Haruyoshi
    Kim, Kyeong J.
    Matias-Lopes, Jose A.
    Martinez-Frias, Jesus
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XIX, 2017, 10392