Better Performance With Bone-Anchored Hearing Aid Than Acoustic Devices in Patients With Severe Air-Bone Gap

被引:34
|
作者
de Wolf, Maarten J. F. [1 ]
Hendrix, Sander [1 ]
Cremers, Cor W. R. J. [1 ]
Snik, Ad F. M. [1 ]
机构
[1] Radboud Univ Nijmegen, Dept Otorhinolaryngol, Donders Ctr Neurosci, Nijmegen Med Ctr,UMC St Radboud, NL-6500 HB Nijmegen, Netherlands
来源
LARYNGOSCOPE | 2011年 / 121卷 / 03期
关键词
BAHA; APHAB; speach recognition; BTE; mixed hearing loss; NOISE;
D O I
10.1002/lary.21167
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis: A study performed in the 1990s with analogue linear hearing aids showed that in patients with mixed hearing loss and an air-bone gap that exceeded 25 to 30 dB, speech perception was better with a bone-anchored hearing aid (Baha) than with a conventional behind-the-ear (BTE) device. The objective of the present study was to investigate whether this conclusion applies to today's digital BTEs with feedback cancellation and whether the crossover point still occurs at an air-bone gap of 25 to 30 dB. Study Design: Case control. Methods: Experienced unilateral Baha users with the latest digital Baha processors were fitted with a powerful BTE with feedback cancellation. After an acclimatization period of 4 weeks, aided thresholds and speech recognition scores were determined and compared to those recorded previously with the Baha. To obtain patients' opinions, a disability-specific questionnaire was used. Participants comprised 16 subjects with bilateral mixed hearing loss participated. Results: Audiometric and speech recognition data showed similar trends to those described previously, but the crossover point had shifted to an air-bone gap of 30 to 35 dB. In the questionnaire, the BTE was rated higher than the Baha, except by the patients with an air-bone gap that exceeded an average of 45 dB. Conclusions: In patients with mixed hearing loss whose air-bone gap exceeded 35 dB, speech recognition is likely to be better with a Baha than with a BTE. Therefore, the Baha should receive greater consideration when mixed hearing loss is combined with a significant air-bone gap, even when there are no contraindications for BTEs.
引用
收藏
页码:613 / 616
页数:4
相关论文
共 50 条
  • [31] Bone-anchored hearing aid modified with directional microphone: do patients benefit?
    Blackmore, K. J.
    Kernohan, M. D.
    Davison, T.
    Johnson, I. J. M.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2007, 121 (09): : 822 - 825
  • [32] Tissue Preservation Techniques for Bone-Anchored Hearing Aid Surgery
    Holmes, Sean
    Hamiter, Mickie
    Berry, Camille
    Mankekar, Gauri
    OTOLOGY & NEUROTOLOGY, 2021, 42 (07) : 1044 - 1050
  • [33] Imaging procedures after bone-anchored hearing aid implantation
    Arndt, Susan
    Kromeier, Jan
    Berlis, Ansgar
    Maier, Wolfgang
    Laszig, Roland
    Aschendorff, Antje
    LARYNGOSCOPE, 2007, 117 (10): : 1815 - 1818
  • [34] Results and complications of the Baha system (bone-anchored hearing aid)
    Ricci, G.
    Della Volpe, A.
    Faralli, M.
    Longari, F.
    Gulla, M.
    Mansi, N.
    Frenguelli, A.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2010, 267 (10) : 1539 - 1545
  • [35] Bone-anchored hearing aid: Comparison of benefit by patient subgroups
    McLarnon, CM
    Davison, T
    Johnson, IJM
    LARYNGOSCOPE, 2004, 114 (05): : 942 - 944
  • [36] Bone-Anchored Hearing Aid: Patient Satisfaction With the Cordelle Device
    Ho, Eu Chin
    Monksfield, Peter
    Egan, Elizabeth
    Reid, Andrew
    Proops, David
    OTOLOGY & NEUROTOLOGY, 2009, 30 (06) : 793 - 799
  • [37] The bone-anchored hearing aid: Reference quantities and functional gain
    Carlsson, PU
    Hakansson, BEV
    EAR AND HEARING, 1997, 18 (01): : 34 - 41
  • [38] The bone-anchored hearing aid - Quality-of-life assessment
    Hol, MKS
    Spath, MA
    Krabbe, PFM
    van der Pouw, CTM
    Snik, AFM
    Cremers, CWRJ
    Mylanus, EAM
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2004, 130 (04) : 394 - 399
  • [39] Bone-Anchored Hearing Aid Subjective Benefit for Unilateral Deafness
    House, John W.
    Kutz, Joe Walter, Jr.
    Chung, Janice
    Fisher, Laurel M.
    LARYNGOSCOPE, 2010, 120 (03): : 601 - 607
  • [40] Insufficient cranial thickness in bone-anchored hearing aid placement
    Brenner, Michael J.
    Goebel, Joel A.
    Wippold, Franz J., II
    OTOLOGY & NEUROTOLOGY, 2007, 28 (06) : 865 - 866