Triamine-bonded stationary phase for open tubular capillary electrochromatography

被引:11
|
作者
Zhang, Xiaowei [1 ]
Lin, Xucong [1 ]
Chen, Zhenbin [1 ]
Wang, Xiaochun [1 ]
Wu, Xiaoping [1 ]
Xie, Zenghong [1 ,2 ]
机构
[1] Fuzhou Univ, Inst Food Safety & Environm Monitoring, Fuzhou 350108, Fujian, Peoples R China
[2] Xiamen Huaxia Vocat Coll, Xiamen, Peoples R China
关键词
Anodic EOF; Open tubular capillary electrochromatography; Triamine-bonded; TENTACLE-TYPE POLYMER; LIQUID-CHROMATOGRAPHY; ELECTROOSMOTIC FLOW; RECENT PROGRESS; BASIC-PROTEINS; SEPARATION; ELECTROPHORESIS; COLUMNS; CEC; NANOPARTICLES;
D O I
10.1002/jssc.201000174
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multi functional separation column modified with 3 [2 (2 aminoethylamino)ethyl amino] propyl trimethoxysilane was developed for open tubular capillary electrochromatography This functional hydrophilic triamine bonded open tubular column could generate both anodic and cathodic EOF When the pH of the running buffer was below 5 3 (30% 3 [2 (2 aminoethylamino)ethylamino] propyl trimethoxysilane v/v) the anodic EOF was exhibited which greatly prevented the undesired adsorptions of basic proteins on the capillary inner wall Favorable separation of four basic proteins (viz trypsin ribonuclease A lysozyme and cytochrome c) was successfully achieved at pH 3 5 of 10 mmol/L phosphate buffer The column efficiencies of proteins were in the range from 87 000 to 110 000 plates/m and the RSD values for migration time of four proteins were less than 1 2% (run to run n = 5) The ionic analytes were also separated efficiently in the co electroosmotic mode The average efficiencies ranged from 81 000 to 190 000 plates/m for seven aromatic acids and 186 000-245 000 plates/m for four nucleoside mono phosphates respectively and good capillary column repeatability was gained with RSD of the migration time not more than 3 0% The triamine bonded open tubular capillary column is favorable to be an alternative functional medium for the further analysis of basic proteins and anionic analytes
引用
收藏
页码:3184 / 3193
页数:10
相关论文
共 50 条
  • [31] Polymer-brush stationary phases for open-tubular capillary electrochromatography
    Miller, MD
    Baker, GL
    Bruening, ML
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) : 323 - 330
  • [32] Sol-gel technique for the preparation of β-cyclodextrin derivative stationary phase in open-tubular capillary electrochromatography
    Wang, YC
    Zeng, ZR
    Guan, N
    Cheng, JK
    ELECTROPHORESIS, 2001, 22 (11) : 2167 - 2172
  • [33] Room-temperature growth of covalent organic frameworks as the stationary phase for open-tubular capillary electrochromatography
    Li, Qiaoyan
    Li, Zhentao
    Fu, Yuanyuan
    Clarot, Igor
    Boudier, Ariane
    Chen, Zilin
    ANALYST, 2021, 146 (21) : 6643 - 6649
  • [34] Enantioselective open-tubular capillary electrochromatography using cyclodextrin-modified gold nanoparticles as stationary phase
    Li, Min
    Liu, Xi
    Jiang, Fengyi
    Guo, Liping
    Yang, Li
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (23) : 3725 - 3729
  • [35] Synthesis of carbon dots-based covalent organic nanomaterial as stationary phase for open tubular capillary electrochromatography
    Fu, Yuanyuan
    Li, Zhentao
    Hu, Changjun
    Li, Qiaoyan
    Chen, Zilin
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1678
  • [36] Chiral zeolite beta used as stationary phase for enantioseparation in miniaturized open tubular capillary electrochromatography with amperometric detection
    Yang, Li
    Liu, Ru
    Li, Chaodan
    Gu, Boning
    Ye, Jiannong
    Chen, Li
    Chu, Qingcui
    ANALYTICA CHIMICA ACTA, 2024, 1292
  • [37] Separation of monoclonal antibody charge state variants by open tubular capillary electrochromatography with immobilised protein as stationary phase
    Zhang, Yamin
    Wang, Wentao
    Xiao, Xue
    Jia, Li
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1466 : 180 - 188
  • [38] Polystyrene monolithic column functionalized with copper-iminodiacetate complex as a stationary phase for open tubular capillary electrochromatography
    Chuang, SC
    Chang, CY
    Liu, CY
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) : 229 - 236
  • [39] Investigation of factors influencing the performance open-tubular stationary phases in capillary electrochromatography
    Freitag, R
    Constantin, S
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (9-10) : 835 - 843
  • [40] Polymer-brush stationary phases for open-tubular capillary electrochromatography.
    Miller, MD
    Bruening, ML
    Baker, GL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 227 : U118 - U118