Quantitative Analysis of Indoor Gaseous Semi-Volatile Organic Compounds Using Solid-Phase Microextraction: Active Sampling and Calibration

被引:4
|
作者
Cao, Jianping [1 ,2 ]
Zhang, Li [1 ]
Cheng, Zhibin [1 ]
Xie, Siqi [1 ]
Li, Runze [1 ]
Xu, Ying [3 ]
Huang, Haibao [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Sch Environm Sci & Engn, Guangzhou 510006, Peoples R China
[2] Guangdong Prov Key Lab Environm Pollut Control &, Guangzhou 510006, Peoples R China
[3] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
关键词
indoor air quality; semi-volatile organic compounds; solid-phase microextraction; active sampling; gas-phase concentration; chemical analysis; AIR; SPME; EMISSIONS; EXPOSURE;
D O I
10.3390/atmos13050693
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Semi-volatile organic compounds (SVOCs) are important pollutants in indoor environments. Quantification of gaseous SVOC concentrations is essential to assess the pollution levels. Solid-phase microextraction (SPME) is considered to be an attractive sampling technique with merits, including simplicity of use, rapid sampling, and solvent free. However, the applications of SPME for sampling gaseous SVOCs are often limited by the fluctuating velocity of indoor air (leading to an unstable sampling rate) and the uncertainties associated with the traditional calibration of SPME. Therefore, we established an SPME-based active sampler to ensure the stable sampling of SVOCs in fluctuating air and developed a two-step calibration method based on the sampling principle of SPME. The presented method and a traditional method (sorbent tubes packed with Tenax TA) were simultaneously used to measure SVOC concentrations in an airstream generated in experiments. Three typical indoor SVOCs, diisobutyl phthalate (DiBP), tris (1-chloro-2-propyl) phosphate (TCPP), and benzyl butyl phthalate (BBzP) were chosen as the analytes. Mean concentrations measured by SPME agreed well with the sorbent tubes (relative deviations <12%), supporting the feasibility of the presented method. Further studies are expected to facilitate the application of the presented method (especially the problem associated with the sampling-tube loss of low volatile SVOCs).
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Dynamic versus static sampling for the quantitative analysis of volatile organic compounds in air with polydimethylsiloxane - Carboxen solid-phase microextraction fibers
    Tuduri, L
    Desauziers, V
    Fanlo, JL
    JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) : 49 - 56
  • [22] Sampling Dynamics for Volatile Organic Compounds Using Headspace Solid-Phase Microextraction Arrow for Microbiological Samples
    Eckert, Kevin E.
    Carter, David O.
    Perrault, Katelynn A.
    SEPARATIONS, 2018, 5 (03)
  • [23] Understanding semi-volatile organic compounds in indoor dust
    Liu, Xiaoyu
    INDOOR AND BUILT ENVIRONMENT, 2022, 31 (02) : 291 - 298
  • [24] Dynamic air sampling of volatile organic compounds using solid phase microextraction
    Razote, E
    Jeon, I
    Maghirang, R
    Chobpattana, W
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2002, 37 (04) : 365 - 378
  • [25] Sampling volatile organic compounds using a modified solid phase microextraction device
    Zhang, ZY
    Pawliszyn, J
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1996, 19 (03): : 155 - 160
  • [26] Sampling volatile organic compounds using a modified solid phase microextraction device
    Zhang, Zhouyao
    Pawliszyn, J.
    Journal of High Resolution Chromatography, 1996, 19 (03):
  • [27] Solid-phase microextraction of volatile organic compounds in environmental applications
    Dewulf, J
    Van Langenhove, H
    AMERICAN LABORATORY, 2001, 33 (04) : 18 - +
  • [28] Simultaneous Extraction and Determination of Volatile Organic Compounds and Semi-volatile Organic Compounds in Indoor Air Using Multi-bed Solid Phase Extraction Device
    Ikuo Ueta
    Risa Takenaka
    Koji Fujimura
    Tomotaka Yoshimura
    Shoji Narukami
    Suguru Mochizuki
    Tsuneaki Maeda
    Analytical Sciences, 2020, 36 : 1071 - 1074
  • [29] Potential of solid-phase microextraction fibers for the analysis of volatile organic compounds in air
    Tuduri, L
    Desauziers, V
    Fanlo, JL
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2001, 39 (12) : 521 - 529
  • [30] Simultaneous Extraction and Determination of Volatile Organic Compounds and Semi-volatile Organic Compounds in Indoor Air Using Multi-bed Solid Phase Extraction Device
    Ueta, Ikuo
    Takenaka, Risa
    Fujimura, Koji
    Yoshimura, Tomotaka
    Narukami, Shoji
    Mochizuki, Suguru
    Maeda, Tsuneaki
    ANALYTICAL SCIENCES, 2020, 36 (09) : 1071 - 1074