Parallelized multi-layered Monte Carlo Model for Evaluation of a Proximal Phalanx Photoplethysmograph

被引:2
|
作者
Fine, Jesse [1 ]
Boonya-ananta, Tananant [2 ]
Rodriguez, Andres [2 ]
Ramella-Roman, Jessica [2 ]
McShane, Mike [1 ,3 ]
Cote, Gerard L. [1 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] Florida Int Univ, Dept Biomed Engn, Miami, FL 33199 USA
[3] Texas A&M Univ, Dept Mat Sci & Engn, College Stn, TX 77843 USA
基金
美国国家科学基金会;
关键词
Monte Carlo Method; Photon Transport; Continuous Monitoring; Photoplethysmogram; Remote Health; Computational Modeling; PULSE TRANSIT-TIME; DIFFERENT BODY SITES; SKIN; HYPERTENSION; THICKNESS; ECG;
D O I
10.1117/12.2543590
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Blood pressure is a primary candidate to be remotely characterized by continuous monitoring devices, as high blood pressure is frequently a symptom of chronic conditions such as diabetes, obesity, and cardiovascular disease while also leading to morbidity itself. Much work has been done to characterize an electrocardiogram (EKG)-photoplethysmogram (PPG) continuous monitor, however a dual PPG continuous monitor may yield more accurate results due to the lack of the inherent pre-ejection period. To predict the anticipated signal of a remote dual-photoplethysmogram (PPG) blood pressure monitor, we utilized parallelized multi-layer Monte Carlo modelling to estimate light transport through the index finger at the proximal phalange. Monte Carlo models of the digital artery and surrounding tissue were created that represent various skin tones as well as the presence of arterioles. Additionally, the signal contribution by arteriole and artery was also determined. By varying incident wavelength, source-detector separation, skin tone, and arterial diameter as a function of pulse propagation; the feasibility of a proximal phalange PPG can be estimated and further optimized to aid development of a dual-PPG blood pressure monitor. The modelling results indicate that at a separation of 3.0mm, 700nm wavelength provides signal resolution that is indicative of contribution from the artery and not the arterioles, which could be beneficial for estimating pulse transit time toward calculating blood pressure. Further work should be completed to optimize source-detector separation for arterial contribution to signal and explore various locations on the body, as much optical property variation exists within literature.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] A multi-layered general agent model
    Costantini, Stefania
    Tocchio, Arianna
    Toni, Francesca
    Tsintza, Panagiota
    AI(ASTERISK)IA 2007: ARTIFICIAL INTELLIGENCE AND HUMAN-ORIENTED COMPUTING, 2007, 4733 : 121 - +
  • [22] Comparison of an accelerated weighted fluorescence Monte Carlo simulation method with reference methods in multi-layered turbid media
    Hennig, Georg
    Stepp, Herbert
    Sroka, Ronald
    Beyer, Wolfgang
    APPLIED OPTICS, 2013, 52 (05) : 1066 - 1075
  • [23] Optical properties of blueberry flesh and skin and Monte Carlo multi-layered simulation of light interaction with fruit tissues
    Zhang, Mengyun
    Li, Changying
    Yang, Fuzeng
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2019, 150 : 28 - 41
  • [24] Comparison between finite element method and Monte Carlo results in spectroscopy studies for multi-layered biomedical tissues
    Kervella, Marine
    L'Huillier, Jean-Pierre
    Humeau, Anne
    BIOPHOTONICS AND NEW THERAPY FRONTIERS, 2006, 6191
  • [25] Monte Carlo simulation using DETECT2000 of a multi-layered scintillation block and fit to experimental data
    Cayouette, F
    Zhang, N
    Thompson, CJ
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1167 - 1171
  • [26] Modelling spatially-resolved diffuse reflectance spectra of a multi-layered skin model by artificial neural networks trained with Monte Carlo simulations
    Tsui, Sheng-Yang
    Wang, Chiao-Yi
    Huang, Tsan-Hsueh
    Sung, Kung-Bin
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (04): : 1531 - 1544
  • [27] Approach of mechanics model of multi-layered barrels
    Zhang, Yue
    Fan, Xinmin
    Kong, Deren
    Dandao Xuebao/Journal of Ballistics, 1998, 10 (03): : 20 - 24
  • [28] A multi-layered database model for mobile environment
    Madria, SK
    Fu, YJ
    Bhowmick, S
    MOBILE DATA MANAGEMENT, PROCEEDINGS, 2003, 2574 : 381 - 385
  • [29] Model Suites For Multi-Layered Database Modelling
    Thalheim, Bernhard
    INFORMATION MODELLING AND KNOWLEDGE BASES XXI, 2010, 206 : 116 - 134
  • [30] MULTI-LAYERED MODEL OF E-LOGISTIC
    Al Majzoub, Mohamad
    Davidaviciene, Vida
    10TH INTERNATIONAL SCIENTIFIC CONFERENCE BUSINESS AND MANAGEMENT 2018, 2018, : 121 - 131