k(Q) factors for ionization chamber dosimetry in clinical proton beams

被引:23
|
作者
Vatnitsky, SM
Siebers, JV
Miller, DW
机构
[1] Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda
关键词
protons; ionization chamber dosimetry; calorimeter; absorbed dose to water;
D O I
10.1118/1.597768
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We discuss a formalism for clinical proton beam dosimetry based on the use of ionization chamber absorbed dose-to-water calibration and beam quality correction factors. A quantity k(Q), the beam quality correction factor, is defined which corrects the absorbed dose-to-water calibration factor N-D,N-w, in a reference beam of quality Q(0) to that in a user's beam of quality Q(1). This study of proton beam quality correction factors used Co-60 (k(Q gamma)) and proton (k(Qp)) reference beams. The k(Q gamma) factors were measured using combined water calorimetry and ionometry for PTW and Capintec-Farmer-type ionization chambers, and were computed from standard dosimetry protocols. Agreement between measured and calculated k(Q gamma), values for both chambers was found within 1.2% in the plateau region for a monoenergetic 250-MeV beam and within 1.8% at the spread-out Bragg peak for a 155-MeV range-modulated beam. Comparison of absorbed doses to water determined in the range modulated 155-MeV beam was performed with the PTW chamber using three calibration methods: N-gas calibration (AAPM Report 16), N-D,N-w,N-gamma calibration in a Co-60 beam in conjunction with a k(Q gamma) factor, and N-D,N-w,N-p calibration in a proton beam in conjunction with a k(Qp), factor. Absorbed doses to water obtained with the three methods agreed within 2% when ionization chamber dosimetry data were analyzed using the proton W-value for air from the AAPM Report 16 and the ICRU 49 proton stopping powers. The use of the proton-calibrated reference ionization chamber, in conjunction with the beam quality correction factor k(Qp), significantly reduced the systematic uncertainty of the absorbed dose determination. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 50 条
  • [11] Analytical expressions for the determination of the effective water depth of an ionization chamber for clinical proton beam dosimetry
    Palmans, H
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 868 - 871
  • [12] CORRECTION FACTORS FOR IONIZATION CHAMBER DOSIMETRY IN TOMOTHERAPY AND CYBERKNIFE
    Gago-Arias, A.
    Pardo-Montero, J.
    Rodriguez-Romero, R.
    Sanchez-Rubio, P.
    Gonzalez-Castano, D. M.
    Palmans, H.
    Sharpe, P.
    Fayos, F.
    Antolin, E.
    Simon, R.
    Gomez, F.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S131 - S131
  • [13] Radiochromic film dosimetry for clinical proton beams
    Vatnitsky, SM
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (05) : 643 - 651
  • [14] Comparison of dosimetry recommendations for clinical proton beams
    Medin, J
    Andreo, P
    Vynckier, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11): : 3195 - 3211
  • [15] Development of a guarded liquid ionization chamber for clinical dosimetry
    Stewart, K. J.
    Elliott, A.
    Seuntjens, J. P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (11): : 3089 - 3104
  • [16] Proton beam dosimetry: A comparison between the Faraday cup and an ionization chamber
    Cambria, R
    Herault, J
    Brassart, N
    Silari, M
    Chauvel, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (06): : 1185 - 1196
  • [17] Monte Carlo study of conversion factors for ionization chamber dosimetry in solid slab phantoms for MV photon beams
    Park, Dong-wook
    Lee, Jai-ki
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (04) : 647 - 652
  • [18] Monte Carlo study of conversion factors for ionization chamber dosimetry in solid slab phantoms for MV photon beams
    Dong-wook Park
    Jai-ki Lee
    Journal of the Korean Physical Society, 2016, 69 : 647 - 652
  • [19] Direct measurement of ionization chamber absorbed dose kQ factors in clinical electron beams
    Wang, Zhipeng
    Xing, Shuming
    Wang, Kun
    Jin, Sunjun
    Zhang, Jian
    Fan, Fuyou
    RADIATION MEASUREMENTS, 2020, 139
  • [20] Dosimetry of clinical neutron and proton beams: An overview of recommendations
    Vynckier, S
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 565 - 572