k(Q) factors for ionization chamber dosimetry in clinical proton beams

被引:23
|
作者
Vatnitsky, SM
Siebers, JV
Miller, DW
机构
[1] Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda
关键词
protons; ionization chamber dosimetry; calorimeter; absorbed dose to water;
D O I
10.1118/1.597768
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We discuss a formalism for clinical proton beam dosimetry based on the use of ionization chamber absorbed dose-to-water calibration and beam quality correction factors. A quantity k(Q), the beam quality correction factor, is defined which corrects the absorbed dose-to-water calibration factor N-D,N-w, in a reference beam of quality Q(0) to that in a user's beam of quality Q(1). This study of proton beam quality correction factors used Co-60 (k(Q gamma)) and proton (k(Qp)) reference beams. The k(Q gamma) factors were measured using combined water calorimetry and ionometry for PTW and Capintec-Farmer-type ionization chambers, and were computed from standard dosimetry protocols. Agreement between measured and calculated k(Q gamma), values for both chambers was found within 1.2% in the plateau region for a monoenergetic 250-MeV beam and within 1.8% at the spread-out Bragg peak for a 155-MeV range-modulated beam. Comparison of absorbed doses to water determined in the range modulated 155-MeV beam was performed with the PTW chamber using three calibration methods: N-gas calibration (AAPM Report 16), N-D,N-w,N-gamma calibration in a Co-60 beam in conjunction with a k(Q gamma) factor, and N-D,N-w,N-p calibration in a proton beam in conjunction with a k(Qp), factor. Absorbed doses to water obtained with the three methods agreed within 2% when ionization chamber dosimetry data were analyzed using the proton W-value for air from the AAPM Report 16 and the ICRU 49 proton stopping powers. The use of the proton-calibrated reference ionization chamber, in conjunction with the beam quality correction factor k(Qp), significantly reduced the systematic uncertainty of the absorbed dose determination. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 50 条
  • [1] Kscript Q sign factors for ionization chamber dosimetry in clinical proton beams
    Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, CA 92354, United States
    Med. Phys., 1 (25-31):
  • [2] Dosimetry of pulsed clinical proton beams by a small ionization chamber
    Nohtomi, A
    Sakae, T
    Tsunashima, Y
    Kohno, R
    MEDICAL PHYSICS, 2001, 28 (07) : 1431 - 1435
  • [3] Experimental determination of k Q factors for two types of ionization chambers in scanned proton beams
    Medin, Joakim
    Andreo, Pedro
    Palmans, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (05):
  • [4] IONIZATION CHAMBER FOR DOSIMETRY OF 14 MEV NEUTRON BEAMS
    GREENE, D
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (03): : 489 - &
  • [5] A Fano test for proton beams and the influence of nuclear interactions on ionization chamber factors
    Lourenco, A.
    Bouchard, H.
    Galer, S.
    Royle, G.
    Palmans, H.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S31 - S32
  • [6] CALCULATION OF PERTURBATION FACTORS FOR THE PTW 23343 MARKUS IONIZATION CHAMBER IN PROTON BEAMS
    Pietrzak, Robert
    Konefal, Adam
    ACTA PHYSICA POLONICA B, 2017, 48 (03): : 679 - 682
  • [7] Consistency in quality correction factors for ionization chamber dosimetry in scanned proton beam therapy
    Sorriaux, Jefferson
    Testa, Mauro
    Paganetti, Harald
    Bertrand, Damien
    Lee, John Aldo
    Palmans, Hugo
    Vynckier, Stefaan
    Sterpin, Edmond
    MEDICAL PHYSICS, 2017, 44 (09) : 4919 - 4927
  • [8] Water calorimetry and ionization chamber dosimetry in an 85-MeV clinical proton beam
    Palmans, H
    Seuntjens, J
    Verhaegen, F
    Denis, JM
    Vynckier, S
    Thierens, H
    MEDICAL PHYSICS, 1996, 23 (05) : 643 - 650
  • [9] Monte Carlo simulations of ionization chamber perturbation correction factors in monoenergetic proton beams
    Dulkys, A.
    Kretschmer, J.
    Brodbek, L.
    Stelljes, T. S.
    Willborn, K.
    Looe, H. K.
    Poppe, B.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 : S182 - S183
  • [10] Monte Carlo calculated ionization chamber correction factors in clinical proton beams - deriving uncertainties from published data
    Baumann, Kilian-Simon
    Goma, Carles
    Wulff, Joerg
    Kretschmer, Jana
    Zink, Klemens
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 113