Implant placement enhanced by a new bioactive material

被引:0
|
作者
Schepers, E [1 ]
Barbier, L [1 ]
机构
[1] Catholic Univ Louvain, Dept Prosthet Dent, B-3000 Louvain, Belgium
来源
BIOCERAMICS, VOL 10 | 1997年
关键词
D O I
10.1016/B978-008042692-1/50101-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is to determine the efficacy of bioactive glass particles of narrow size range (300-355 mu m, Biogran(TM)) in the treatment of bone defects prior to implant placement. At both sides of the mandible of 6 beagle dogs partial edentulous areas were created with removal of the intra-alveolar septa to obtain large defects, instantly filled at one side with bioactive glass particles. The other side was left empty as a control side. After a healing period of 4 months, 3 oral implants were placed in the glass-treated area and 5 in the control zone. Half of the implants were left subgingivally for 3 months and than resected. The other half of the implants were loaded with fixed prostheses for 7 weeks and than sacrificed. A qualitative and quantitative histological analysis revealed substantially more, bone tissue and a higher and longer lasting remodelling activity around implants placed in glass-treated areas.
引用
收藏
页码:425 / 428
页数:4
相关论文
共 50 条
  • [31] Comparison of Bone Healing in Immediate Implant Placement versus Delayed Implant Placement
    Singh, Gagandeep
    Pareek, Rajat
    Rajawat, Gaurav Singh
    Kadam, Aljeeta
    Al Abdulsalam, Mahmoud
    Al Abdulathim, Abdulrahman
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (06): : S1309 - S1314
  • [32] Experimental studies on a new bioactive material: HAIonomer cements
    Yap, AUJ
    Pek, YS
    Kumar, RA
    Cheang, P
    Khor, KA
    BIOMATERIALS, 2002, 23 (03) : 955 - 962
  • [33] Bioactive silicon nitride: A new therapeutic material for osteoarthropathy
    Giuseppe Pezzotti
    Elia Marin
    Tetsuya Adachi
    Alfredo Rondinella
    Francesco Boschetto
    Wenliang Zhu
    Nobuhiko Sugano
    Ryan M. Bock
    Bryan McEntire
    Sonny B. Bal
    Scientific Reports, 7
  • [34] A new bioactive material which transforms in situ into hydroxyapatite
    De Aza, PN
    Guitian, F
    De Aza, S
    ACTA MATERIALIA, 1998, 46 (07) : 2541 - 2549
  • [35] A histologic study of bone response to bioactive glass particles used before implant placement: A clinical report
    Stvrtecky, R
    Gorustovich, A
    Perio, C
    Guglielmotti, MB
    JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (05): : 424 - 428
  • [36] Evaluation of immediate implant placement with osteotome sinus floor elevation without graft material
    Tamer, Y.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2023, 26 (03) : 274 - 279
  • [37] THE INFLUENCE OF IMPLANT PLACEMENT DEPTH AND IMPRESSION MATERIAL ON THE STABILITY OF AN OPEN TRAY IMPRESSION COPING
    Linkevicius, Tomas
    Svediene, Olga
    Vindasiute, Egle
    Puisys, Algirdas
    Linkeviciene, Laura
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 108 (04): : 238 - 243
  • [38] Bioactive silicon nitride: A new therapeutic material for osteoarthropathy
    Pezzotti, Giuseppe
    Marin, Elia
    Adachi, Tetsuya
    Rondinella, Alfredo
    Boschetto, Francesco
    Zhu, Wenliang
    Sugano, Nobuhiko
    Bock, Ryan M.
    McEntire, Bryan
    Bal, Sonny B.
    SCIENTIFIC REPORTS, 2017, 7
  • [39] A modified method for fabricating a radiographic stent with transparent occlusal registration material for implant placement
    Lee, Jung-Jin
    Seo, Jae-Min
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04): : 569 - 570
  • [40] Proposal for a New Bioactive Kinetic Screw in an Implant, Using a Numerical Model
    Andreucci, Carlos Aurelio
    Alshaya, Abdullah
    Fonseca, Elza M. M.
    Jorge, Renato N.
    APPLIED SCIENCES-BASEL, 2022, 12 (02):