Evaluation of absolute cerebral blood flow by laser-Doppler scanning - Comparison with hydrogen clearance

被引:22
|
作者
Uranishi, R
Nakase, H
Sakaki, T
Kempski, OS
机构
[1] Nara Med Univ, Dept Neurosurg, Kashihara, Nara 634, Japan
[2] Johannes Gutenberg Univ Mainz, Inst Neurosurg Pathophysiol, D-6500 Mainz, Germany
关键词
cerebral blood flow; laser-Doppler flowmetry; laser-Doppler scanning; global ischemia; rat;
D O I
10.1159/000025631
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A major limitation of laser-Doppler (LD) flowmetry, which enables noninvasive and continuous recording of tissue perfusion, is its inability to evaluate the absolute cerebral blood flow (CBF). Using a computer-controlled micromanipulator, the LD scanning technique provides information on the brain microcirculation in many different locations, information which is not available from a si ng le stationary probe. The purpose of the current study was to examine whether LD scanning estimates can be calibrated for the absolute CBF by comparing LD scanning with the hydrogen clearance (HC) method. In Wistar rats (n = 31) including old rats (122-123 weeks old, n = 8), the CBF was altered using the global ischemia model by bilateral carotid artery occlusion coupled with hypobaric hypotension. The CBF was determined simultaneously by the LD scanning technique and HC at each mean arterial blood pressure step, and the correlation of CBF between the two techniques was analyzed, CBF measured by LD scanning was expressed as LD units. Absolute CBF values obtained by methods were correlated (r = 0.87), and the formula to calibrate absolute CBF values from LD units was y = 1.8x - 0.6. On the other hand, in old rats the formula to calibrate the absolute values was different (y = 1.3x + 8.3, r = 0.85). The results suggest that CBF data obtained by LD scanning could be calibrated into absolute blood flow values in particular circumstances, and that LD scanning could compensate in part for the weakness of LD flowmetry.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [21] Comparison of cerebral blood flow (CBF) measurements by hydrogen clearance and laser Doppler flowmetry (LDF) during progressive hemodilution in rats.
    Bedell, EA
    DeWitt, DS
    Prough, DS
    ANESTHESIOLOGY, 1999, 91 (3A) : U343 - U343
  • [22] LASER-DOPPLER SYSTEM FOR RAPID SCANNING OF FLOW-FIELDS
    DURST, F
    LEHMANN, B
    TROPEA, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1981, 52 (11): : 1676 - 1681
  • [23] CONTINUOUS MONITORING OF POSTTRAUMATIC CEREBRAL BLOOD-FLOW USING LASER-DOPPLER FLOWMETRY
    MUIR, JK
    BOERSCHEL, M
    ELLIS, EF
    JOURNAL OF NEUROTRAUMA, 1992, 9 (04) : 355 - 362
  • [24] CHOROIDAL BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY
    RIVA, CE
    PETRIG, BL
    OPTICAL ENGINEERING, 1995, 34 (03) : 746 - 752
  • [25] COMPARISON OF BLOOD-FLOW MEASUREMENTS BY HYDROGEN GAS CLEARANCE AND LASER DOPPLER FLOWMETRY IN THE RAT DUODENUM
    LEUNG, FW
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1990, 25 (05) : 429 - 434
  • [26] LASER-DOPPLER MEASUREMENT OF TRACHEAL MUCOSAL BLOOD-FLOW - COMPARISON WITH TRACHEAL ARTERIAL FLOW
    CORFIELD, DR
    DEFFEBACH, ME
    ERJEFALT, I
    SALONEN, RO
    WEBBER, SE
    WIDDICOMBE, JG
    JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (01) : 274 - 281
  • [27] NONINVASIVE MEASUREMENT OF SKIN BLOOD-FLOW - COMPARISON BETWEEN PLETHYSMOGRAPHY, LASER-DOPPLER FLOWMETER AND HEAT THERMAL CLEARANCE METHOD
    SAUMET, JL
    DITTMAR, A
    LEFTHERIOTIS, G
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (01): : 73 - 83
  • [28] PERFUSION IMAGING OF SKIN ISLAND FLAP BLOOD-FLOW BY A SCANNING LASER-DOPPLER TECHNIQUE
    ARNOLD, F
    HE, CF
    JIA, CY
    CHERRY, GW
    BRITISH JOURNAL OF PLASTIC SURGERY, 1995, 48 (05): : 280 - 287
  • [29] CEREBRAL BLOOD-FLOW AND RESISTANCES DURING HYPOTENSIVE HEMORRHAGE IN THE RABBIT - TRANSCRANIAL DOPPLER AND LASER-DOPPLER FLOWMETRY
    LEFTHERIOTIS, G
    GERAUD, JM
    PRECKEL, MP
    SAUMET, JL
    CLINICAL PHYSIOLOGY, 1995, 15 (06): : 537 - 545
  • [30] HYBRID BLOOD-FLOW PROBE FOR SIMULTANEOUS H-2 CLEARANCE AND LASER-DOPPLER VELOCIMETRY
    DIRESTA, GR
    KIEL, JW
    RIEDEL, GL
    KAPLAN, P
    SHEPHERD, AP
    AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (04): : G573 - G581