Evaluation of absolute cerebral blood flow by laser-Doppler scanning - Comparison with hydrogen clearance

被引:22
|
作者
Uranishi, R
Nakase, H
Sakaki, T
Kempski, OS
机构
[1] Nara Med Univ, Dept Neurosurg, Kashihara, Nara 634, Japan
[2] Johannes Gutenberg Univ Mainz, Inst Neurosurg Pathophysiol, D-6500 Mainz, Germany
关键词
cerebral blood flow; laser-Doppler flowmetry; laser-Doppler scanning; global ischemia; rat;
D O I
10.1159/000025631
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A major limitation of laser-Doppler (LD) flowmetry, which enables noninvasive and continuous recording of tissue perfusion, is its inability to evaluate the absolute cerebral blood flow (CBF). Using a computer-controlled micromanipulator, the LD scanning technique provides information on the brain microcirculation in many different locations, information which is not available from a si ng le stationary probe. The purpose of the current study was to examine whether LD scanning estimates can be calibrated for the absolute CBF by comparing LD scanning with the hydrogen clearance (HC) method. In Wistar rats (n = 31) including old rats (122-123 weeks old, n = 8), the CBF was altered using the global ischemia model by bilateral carotid artery occlusion coupled with hypobaric hypotension. The CBF was determined simultaneously by the LD scanning technique and HC at each mean arterial blood pressure step, and the correlation of CBF between the two techniques was analyzed, CBF measured by LD scanning was expressed as LD units. Absolute CBF values obtained by methods were correlated (r = 0.87), and the formula to calibrate absolute CBF values from LD units was y = 1.8x - 0.6. On the other hand, in old rats the formula to calibrate the absolute values was different (y = 1.3x + 8.3, r = 0.85). The results suggest that CBF data obtained by LD scanning could be calibrated into absolute blood flow values in particular circumstances, and that LD scanning could compensate in part for the weakness of LD flowmetry.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [1] Comparison of cerebral blood flow measured by laser-Doppler flowmetry and hydrogen clearance in cats after cerebral insult and hypervolemic hemodilution
    Kramer, MS
    Vinall, PE
    Katolik, LI
    Simeone, FA
    NEUROSURGERY, 1996, 38 (02) : 355 - 360
  • [3] CEREBRAL BLOOD-FLOW AUTOREGULATION DURING HYPOBARIC HYPOTENSION ASSESSED BY LASER-DOPPLER SCANNING
    HEIMANN, A
    KROPPENSTEDT, S
    ULRICH, P
    KEMPSKI, OS
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1994, 14 (06): : 1100 - 1105
  • [4] Novel intraoperative cerebral blood flow monitoring by laser-Doppler scanner
    Nakase, H
    Kaido, T
    Okuno, S
    Hoshida, T
    Sakaki, T
    NEUROLOGIA MEDICO-CHIRURGICA, 2002, 42 (01) : 1 - 4
  • [5] On the number of measurement sites required to assess regional cerebral blood flow by laser-Doppler scanning during cerebral ischemia and reperfusion
    Soehle, M
    Heimann, A
    Kempski, O
    JOURNAL OF NEUROSCIENCE METHODS, 2001, 110 (1-2) : 91 - 94
  • [6] Novel intraoperative cerebral blood flow monitoring by laser-Doppler scanner - Commentary
    Barrow, DL
    NEUROLOGIA MEDICO-CHIRURGICA, 2002, 42 (01) : 4 - 4
  • [7] LASER-DOPPLER MEASUREMENT OF SKIN BLOOD-FLOW - COMPARISON WITH PLETHYSMOGRAPHY
    JOHNSON, JM
    TAYLOR, WF
    SHEPHERD, AP
    PARK, MK
    JOURNAL OF APPLIED PHYSIOLOGY, 1984, 56 (03) : 798 - 803
  • [8] INTRAOPERATIVE MEASUREMENT OF CEREBRAL AND TUMOR BLOOD-FLOW WITH LASER-DOPPLER FLOWMETRY
    ARBIT, E
    DIRESTA, GR
    BEDFORD, RF
    SHAH, NK
    GALICICH, JH
    NEUROSURGERY, 1989, 24 (02) : 166 - 170
  • [9] THE CHARACTERISTICS OF LASER-DOPPLER FLOWMETRY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW
    FUKUDA, O
    ENDO, S
    KUWAYAMA, N
    HARADA, J
    TAKAKU, A
    NEUROSURGERY, 1995, 36 (02) : 358 - 364
  • [10] RAPID AUTOREGULATION OF CEREBRAL BLOOD-FLOW - A LASER-DOPPLER FLOWMETRY STUDY
    FLORENCE, G
    SEYLAZ, J
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1992, 12 (04): : 674 - 680