Quantification of the salivary volume flow rate in the parotid duct using the time-spatial labeling inversion pulse (Time-SLIP) technique at MRI: A feasibility study

被引:3
|
作者
Fukumoto, Wataru [1 ]
Higaki, Toru [1 ]
Matsuoka, Yoshiko [2 ]
Tatsugami, Fuminari [1 ]
Baba, Yasutaka [1 ]
Iida, Makoto [1 ]
Awai, Kazuo [1 ]
机构
[1] Hiroshima Univ, Inst Biomed Hlth Sci, Dept Diagnost Radiol, Hiroshima, Japan
[2] Hiroshima Univ Hosp, Dept Diagnost Radiol, Hiroshima, Japan
关键词
salivary flow; flow imaging; Time-SLIP technique; CINE-DYNAMIC MRCP; PANCREATIC-JUICE; SECRETORY FLOW; GLAND; ANGIOGRAPHY; SIALOGRAPHY; VISUALIZATION; PHYSIOLOGY;
D O I
10.1002/jmri.25846
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundWe developed a method to quantify the volume flow rate (VFR) using the time-spatial labeling inversion pulse (Time-SLIP) technique to evaluate salivary function. Purpose/HypothesisTo investigate the accuracy of quantification of the salivary VFR using the Time-SLIP technique in phantoms and to examine the feasibility of its use in human subjects. Study TypeThis was a prospective phantom and volunteer study. Population/Subjects/Phantom/Specimen/Animal ModelA phantom and 23 normal volunteers who fasted at least 2 hours study was performed. Field Strength/SequenceFlow images of the phantom and the parotid duct of 23 volunteers were acquired on a 3T-MRI scanner using the Time-SLIP technique. AssessmentHypothesizing that flow aggregates in the conducting duct, we measured the VFR on flow images. In the phantom study, the actual VFR (slow, medium, fast flow) was controlled by an automatic pump system and the measured VFR was compared with the actual VFR on flow images. In the human study we injected citric acid into the mouth of healthy volunteers to stimulate saliva secretion and recorded the VFR. Statistical TestsAs this study was a feasibility study, statistical tests were not performed. ResultsIn the phantom study, the VFR at slow, medium, and fast flow was 5.70.4 (SD), 8.40.3, and 12.21.1mm(3)/sec, respectively. The error between the measured and actual VFR values was 2.8-3.7%. Salivary flow in the parotid duct was visualized in 22 of the 23 volunteers. The mean VFR was 8760mm(3)/10min. Data ConclusionWhen salivary flow was stimulated with citric acid in normal volunteers, the salivary VFR could be obtained using the Time-SLIP technique. Level of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:928-935.
引用
收藏
页码:928 / 935
页数:8
相关论文
共 29 条
  • [21] Current and Emerging MR Imaging Techniques for the Diagnosis and Management of CSF Flow Disorders: A Review of Phase-Contrast and Time-Spatial Labeling Inversion Pulse
    Yamada, S.
    Tsuchiya, K.
    Bradley, W. G.
    Law, M.
    Winkler, M. L.
    Borzage, M. T.
    Miyazaki, M.
    Kelly, E. J.
    McComb, J. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (04) : 623 - 630
  • [22] Comparison of axial and coronal acquisitions by non-contrast-enhanced renal 3D MR angiography using flow-in time-spatial labeling inversion pulse
    Junji Takahashi
    Yuki Ohmoto-Sekine
    Takashi Yoshida
    Mitsue Miyazaki
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2020, 33 : 95 - 102
  • [23] Comparison of axial and coronal acquisitions by non-contrast-enhanced renal 3D MR angiography using flow-in time-spatial labeling inversion pulse
    Takahashi, Junji
    Ohmoto-Sekine, Yuki
    Yoshida, Takashi
    Miyazaki, Mitsue
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (01) : 95 - 102
  • [24] Radiological Analysis of Cerebrospinal Fluid Dynamics at the Craniovertebral Junction Using Time-Spatial Labeling Inversion Pulse Magnetic Resonance Imaging in Patients with Cervical Spinal Canal Stenosis
    Yamahata, Hitoshi
    Ijiri, Kosei
    Tanabe, Fumito
    Murasumi, Kyoichi
    Nagano, Yushi
    Makino, Ryutaro
    Higa, Nayuta
    Hanaya, Ryosuke
    WORLD NEUROSURGERY, 2024, 184 : E731 - E736
  • [25] Non-contrast-enhanced pulmonary perfusion using a time-spatial labeling inversion tag (t-SLIT) pulse in 3D half-Fourier FSE
    Miyazaki, M
    Kanazawa, H
    RADIOLOGY, 2002, 225 : 316 - 316
  • [26] Visualization of External Carotid Artery and Its Branches: Non-contrast-Enhanced MR Angiography Using Balanced Steady-State Free-Precession Sequence and a Time-Spatial Labeling Inversion Pulse
    Satogami, Naoe
    Okada, Tomohisa
    Koyama, Takashi
    Gotoh, Kimio
    Kamae, Toshikazu
    Togashi, Kaori
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 678 - 683
  • [27] Left Gastric Vein Visualization with Hepatopetal Flow Information in Healthy Subjects Using Non-Contrast-Enhanced Magnetic Resonance Angiography with Balanced Steady-State Free-Precession Sequence and Time-Spatial Labeling Inversion Pulse
    Furuta, Akihiro
    Isoda, Hiroyoshi
    Ohno, Tsuyoshi
    Ono, Ayako
    Yamashita, Rikiya
    Arizono, Shigeki
    Kido, Aki
    Sakashita, Naotaka
    Togashi, Kaori
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (01) : 32 - 39
  • [28] Identification of peripheral vessels in oral and maxillofacial regions on magnetic resonance angiography obtained using a balanced steady-state free-precession sequence with a time-spatial labeling inversion pulse and using fresh blood imaging
    Oda, Masafumi
    Tanaka, Tatsurou
    Yamashita, Yoshihiro
    Kito, Shinji
    Wakasugi-Sato, Nao
    Matsumoto-Takeda, Shinobu
    Nishimura, Shun
    Habu, Manabu
    Kodama, Masaaki
    Uehara, Masataka
    Kaneuji, Tsuyoshi
    Kokuryo, Shinya
    Miyamoto, Ikuya
    Yoshiga, Daigo
    Seta, Yuji
    Tominaga, Kazuhiro
    Yoshioka, Izumi
    Morimoto, Yasuhiro
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (06): : 791 - 797
  • [29] Visualization of Peripheral Blood Vessels on the Lingual Aspect of the Mandible Using a Balanced Steady-State Free-Precession Sequence with a Time-Spatial Labeling Inversion Pulse: Usefulness for Prevention of Severe Complications of Dental Implantation
    Tanaka, Tatsurou
    Kawashima, Yusuke
    Oda, Masafumi
    Wakasugi-Sato, Nao
    Matsumoto-Takeda, Shinobu
    Nishimura, Shun
    Morimoto, Yasuhiro
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (20)