Quantification of the salivary volume flow rate in the parotid duct using the time-spatial labeling inversion pulse (Time-SLIP) technique at MRI: A feasibility study

被引:3
|
作者
Fukumoto, Wataru [1 ]
Higaki, Toru [1 ]
Matsuoka, Yoshiko [2 ]
Tatsugami, Fuminari [1 ]
Baba, Yasutaka [1 ]
Iida, Makoto [1 ]
Awai, Kazuo [1 ]
机构
[1] Hiroshima Univ, Inst Biomed Hlth Sci, Dept Diagnost Radiol, Hiroshima, Japan
[2] Hiroshima Univ Hosp, Dept Diagnost Radiol, Hiroshima, Japan
关键词
salivary flow; flow imaging; Time-SLIP technique; CINE-DYNAMIC MRCP; PANCREATIC-JUICE; SECRETORY FLOW; GLAND; ANGIOGRAPHY; SIALOGRAPHY; VISUALIZATION; PHYSIOLOGY;
D O I
10.1002/jmri.25846
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundWe developed a method to quantify the volume flow rate (VFR) using the time-spatial labeling inversion pulse (Time-SLIP) technique to evaluate salivary function. Purpose/HypothesisTo investigate the accuracy of quantification of the salivary VFR using the Time-SLIP technique in phantoms and to examine the feasibility of its use in human subjects. Study TypeThis was a prospective phantom and volunteer study. Population/Subjects/Phantom/Specimen/Animal ModelA phantom and 23 normal volunteers who fasted at least 2 hours study was performed. Field Strength/SequenceFlow images of the phantom and the parotid duct of 23 volunteers were acquired on a 3T-MRI scanner using the Time-SLIP technique. AssessmentHypothesizing that flow aggregates in the conducting duct, we measured the VFR on flow images. In the phantom study, the actual VFR (slow, medium, fast flow) was controlled by an automatic pump system and the measured VFR was compared with the actual VFR on flow images. In the human study we injected citric acid into the mouth of healthy volunteers to stimulate saliva secretion and recorded the VFR. Statistical TestsAs this study was a feasibility study, statistical tests were not performed. ResultsIn the phantom study, the VFR at slow, medium, and fast flow was 5.70.4 (SD), 8.40.3, and 12.21.1mm(3)/sec, respectively. The error between the measured and actual VFR values was 2.8-3.7%. Salivary flow in the parotid duct was visualized in 22 of the 23 volunteers. The mean VFR was 8760mm(3)/10min. Data ConclusionWhen salivary flow was stimulated with citric acid in normal volunteers, the salivary VFR could be obtained using the Time-SLIP technique. Level of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:928-935.
引用
收藏
页码:928 / 935
页数:8
相关论文
共 29 条
  • [1] Syringomyelia fluid flow on time-spatial labeling inversion pulse (Time-SLIP) images in a dog
    Ito, D.
    Ishikawa, C.
    Sekiguchi, N.
    Kitagawa, M.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2022, 63 (12) : 911 - 911
  • [2] Time-spatial Labeling Inversion Pulse (Time-SLIP) with Pencil Beam Pulse: A Selective Labeling Technique for Observing Cerebrospinal Fluid Flow Dynamics
    Shibukawa, Shuhei
    Miyati, Tosiaki
    Niwa, Tetsu
    Matsumae, Mitsunori
    Ogino, Tetsuo
    Horie, Tomohiko
    Imai, Yutaka
    Muro, Isao
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (03) : 259 - 264
  • [3] Cerebrospinal Fluid Dynamics Analysis Using Time-Spatial Labeling Inversion Pulse (Time-SLIP) Magnetic Resonance Imaging in Mice
    Tomita, Yusuke
    Yagi, Mitsuru
    Seki, Fumiko
    Komaki, Yuji
    Matsumoto, Morio
    Nakamura, Masaya
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (15)
  • [4] Time-Spatial Labeling Inversion Pulse (Time-SLIP) MRI for Evaluating Cerebrospinal Fluid Velocity and Visualizing Flow Dynamics in Patients With Chiari Type I Malformation
    Inoue, Tatsushi
    Joko, Masahiro
    Murayama, Kazuhiro
    Ikedo, Masato
    Saito, Fumiaki
    Muto, Jun
    Takeda, Hiroki
    Kaneko, Shinjiro
    Hirose, Yuichi
    NEUROSURGERY PRACTICE, 2023, 4 (04):
  • [5] Visualization of cerebrospinal fluid flow in syringomyelia through noninvasive magnetic resonance imaging with a time-spatial labeling inversion pulse (Time-SLIP)
    Takeuchi, Kazuhiro
    Ono, Atsushi
    Hashiguchi, Yusuke
    Misawa, Haruo
    Takahata, Tomohiro
    Teramoto, Arubi
    Nakahara, Shinnosuke
    JOURNAL OF SPINAL CORD MEDICINE, 2017, 40 (03): : 368 - 371
  • [6] Comparison of Access Route for Endovascular Treatment by Time-Spatial Labeling Inversion Pulse (Time-SLIP) MRA and Contrast-Enhanced MRA
    Kobayashi, Satoshi
    Osanai, Toshiya
    Sugiyama, Taku
    Fujima, Noriyuki
    Takagi, Ryo
    Yokota, Isao
    Hamaguchi, Akiyoshi
    Nakamura, Toshitaka
    Hida, Kazutoshi
    Fujimura, Miki
    JOURNAL OF NEUROENDOVASCULAR THERAPY, 2023, 17 (06) : 120 - 124
  • [7] Corticomedullary differentiation of the kidney: Evaluation with noncontrast-enhanced steady-state free precession (SSFP) MRI with time-spatial labeling inversion pulse (time-SLIP)
    Kanki, Akihiko
    Ito, Katsuyoshi
    Tamada, Tsutomu
    Noda, Yasufumi
    Yamamoto, Akira
    Tanimoto, Daigo
    Sato, Tomohiro
    Higaki, Atsushi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (05) : 1178 - 1181
  • [9] Nonenhanced renal MR angiography using steady-state free precession (SSFP) and time-spatial labeling inversion pulse (Time-SLIP): repeatability and comparison of different tagging location
    Zhang, Yuyang
    Xing, Zhen
    Liu, Ying
    She, Dejun
    Zeng, Zheng
    Cao, Dairong
    ABDOMINAL IMAGING, 2014, 39 (05): : 1000 - 1008
  • [10] Feasibility of MR perfusion-weighted imaging by use of a time-spatial labeling inversion pulse
    Ishimori Y.
    Kawamura H.
    Monma M.
    Radiological Physics and Technology, 2013, 6 (2) : 461 - 466